Original Industrial Spare Part

Honeywell 05701-A-0326 SPCO Relay Card — Voltage-Free Output Module

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: 05701-A-0326 TSI & Rotating Machinery Monitoring Honeywell

RFQ Ready

Request pricing & availability

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

Honeywell 05701-A-0326 | Reliable Automation Component for Mission-Critical Fire & Safety Systems

Field Application & Operational Analysis

From the perspective of a Site Reliability Engineer managing uptime in life-safety infrastructure, the Honeywell 05701-A-0326 stands as a cornerstone I/O module for sustaining system availability in System 57 fire detection architectures. Its dual-channel, voltage-free relay output design enables seamless integration with building management systems, remote annunciators, and third-party monitoring platforms — eliminating single points of failure in alarm signaling chains. The 05701-A-0326 directly contributes to Operational Excellence by ensuring that alarm and fault signals are transmitted with zero signal contamination across isolated switching contacts, a non-negotiable requirement in mission-critical environments.

Engineered for durability under demanding industrial conditions, this relay card maintains stable performance across a 0°C to 50°C operating range with humidity tolerance up to 95% RH (non-condensing). During installation, engineers should verify DIN rail alignment and confirm that cable runs do not exceed 300 meters using minimum 0.5mm² twisted-pair wiring to preserve signal integrity. Proper torque on terminal connections is essential to prevent intermittent contact resistance — a common root cause of nuisance alarms in high-vibration environments.

As production lines and critical facilities increasingly depend on legacy System 57 panels, maintaining a certified stock of the 05701-A-0326 as a strategic spare part is a fundamental practice in any reliability-driven maintenance program. End-of-life (EOL) module availability directly impacts mean time to repair (MTTR), and sourcing original factory units ensures full backward compatibility without costly system reconfiguration.

Key Operational Features

Dual-Channel SPCO Architecture — Independent changeover contacts per channel support redundant alarm routing for high-availability system designs.
Voltage-Free (Dry Contact) Output — Eliminates ground loop interference; compatible with AC and DC monitoring circuits simultaneously.
Galvanic Isolation at 1500V AC — Protects upstream control logic from downstream fault currents, a critical safeguard in Process Optimization workflows.
Seamless Integration with System 57 — Plug-and-play compatibility across all System 57 panel revisions; no firmware reconfiguration required for standard deployments.
EN54 / UL / FM / CE Certified — Meets international fire safety standards, supporting global project compliance without additional approval overhead.
Compact Form Factor — 120mm — 85mm — 45mm footprint minimizes panel real estate consumption while maximizing I/O density for System Integration projects.

Maintenance & Performance Benchmarks

The 05701-A-0326 is designed to adapt across diverse industrial network architectures — from small-scale single-panel installations to multi-zone, multi-building fire safety networks with centralized SCADA supervision. Its voltage-free contact design allows direct interfacing with Modbus RTU/TCP gateways, enabling remote status polling without additional signal conditioning hardware.

Mechanical contact life exceeds 100,000 operations under rated load, making it suitable for high-cycle alarm test environments. Annual functional testing per NFPA 72 is recommended; replace the module if contact resistance exceeds 0.5Ω or if switching anomalies are detected during routine diagnostics. For facilities undergoing digital transformation, the relay card’s dry-contact outputs are fully compatible with IoT edge gateways, supporting predictive maintenance data pipelines without hardware modification.

In multi-tier industrial network architectures — including distributed control systems (DCS) and hybrid PLC/SCADA environments — the 05701-A-0326 functions as a reliable bridge between life-safety logic controllers and facility-wide Automation Components, ensuring that alarm escalation paths remain intact regardless of network topology changes.

Comprehensive Data Sheet

Attribute Technical Data
Model Number 05701-A-0326
Manufacturer Honeywell
Module Type Double SPCO Relay Output Card
Contact Configuration Single Pole Changeover (SPCO) — 2
Contact Rating (DC) 2A @ 30V DC
Contact Rating (AC) 1A @ 125V AC
Output Type Voltage-Free (Dry Contact)
Supply Voltage 24V DC (System-Powered)
Isolation Voltage 1500V AC
Operating Temperature 0°C to +50°C (32°F to 122°F)
Humidity Tolerance 10% — 95% RH, Non-Condensing
Mounting Style DIN Rail / Panel Mount
Dimensions (L W H) 120mm — 85mm — 45mm
Weight 0.12 kg
Certifications UL, FM, CE, EN54
Compatible Platform Honeywell System 57
Mechanical Life >100,000 operations at rated load
Condition New & Original, Factory Sealed

Professional Logistics & Sourcing Excellence

Every Honeywell 05701-A-0326 unit dispatched from our inventory is shipped in Original Factory Packaging, preserving ESD protection and ensuring that components arrive in as-manufactured condition — a critical requirement for life-safety equipment acceptance testing.

We maintain dedicated global stock of EOL and legacy Automation Components to support facilities where System 57 remains the primary fire detection platform. Same-day dispatch is available for in-stock units when orders are confirmed before the daily logistics cutoff. Worldwide express logistics partnerships ensure delivery to major industrial hubs across North America, Europe, the Middle East, and Asia-Pacific within 3-7 business days.

For procurement teams managing multi-site rollouts or emergency replacement scenarios, consolidated shipment options and advance replacement programs are available upon request — minimizing downtime exposure and supporting your Operational Excellence targets.

Engineering Support & FAQ

Q: What are the step-by-step installation requirements for the 05701-A-0326 in a System 57 panel?
A: Power down the System 57 panel before insertion. Align the relay card with the designated slot on the backplane, apply firm even pressure until the edge connector seats fully, then secure with the retention screw. Re-energize the panel and verify relay status via the panel’s diagnostic display. Confirm NO/NC contact continuity with a calibrated multimeter before returning the system to service.

Q: Which firmware versions are compatible with the 05701-A-0326?
A: The relay card is hardware-agnostic with respect to System 57 panel firmware — it operates as a passive output interface and does not require firmware updates itself. However, panels running firmware v3.2 and above support enhanced relay diagnostic reporting. Consult your panel’s release notes to confirm feature availability.

Q: Can both relay channels switch AC and DC loads simultaneously?
A: Yes. Each SPCO contact is independently rated for 2A @ 30V DC and 1A @ 125V AC. The voltage-free design imposes no polarity constraints, allowing mixed AC/DC load configurations across the two channels without cross-interference.

Q: What is the warranty claim process for the 05701-A-0326?
A: All units carry a 12-month warranty from the date of shipment. To initiate a claim, contact our technical support team with the order reference number, a description of the fault symptom, and photographic evidence of the defect. Advance replacement units are dispatched within 24 hours of claim approval for verified mission-critical applications.

Q: How do I verify relay contact integrity during scheduled maintenance?
A: Use a calibrated low-resistance ohmmeter to measure contact resistance across the NO and NC terminals under de-energized conditions. Resistance should be <0.1Ω for healthy contacts. Values exceeding 0.5Ω indicate contact degradation and the module should be scheduled for replacement at the next maintenance window.

Q: Is the 05701-A-0326 suitable for intrinsically safe (IS) zone installations?
A: The standard 05701-A-0326 is not rated for Zone 0/1 intrinsically safe applications. For hazardous area deployments, a certified IS barrier must be installed between the relay output and the field device. Consult your site’s area classification documentation and applicable IEC 60079 standards before proceeding.


© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667

Product Series

Honeywell Experion Spare Parts

Country of Origin

US

Reviews

There are no reviews yet.

Be the first to review “Honeywell 05701-A-0326 SPCO Relay Card — Voltage-Free Output Module”

Your email address will not be published. Required fields are marked

Catalog Continuation

More Honeywell modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within TSI & Rotating Machinery Monitoring.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack