Original Industrial Spare Part
Allen-Bradley 1756-EN2TR/C Dual-Port EtherNet/IP Bridge | New & Original
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU1756-EN2TR/C
- CategoryPLC & Industrial Automation Modules
- BrandAllen-Bradley (Rockwell)
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Allen-Bradley 1756-EN2TR/C Dual-Port EtherNet/IP Bridge | New & Original with SKU 1756-EN2TR/C.
Allen-Bradley 1756-EN2TR/C | Reliable Dual-Port EtherNet/IP Bridge for Mission-Critical Automation
Field Application & Operational Analysis
From a Site Reliability Engineer’s perspective, network communication redundancy is the single most decisive factor in sustaining system availability on continuous-process production lines. The Allen-Bradley 1756-EN2TR/C addresses this requirement directly — its dual embedded Ethernet ports and native Device Level Ring (DLR) protocol support enable sub-3ms automatic network recovery, ensuring that a single cable fault or node failure never cascades into a full production stoppage. Integrating the 1756-EN2TR/C into a ControlLogix chassis transforms a flat, single-path Ethernet segment into a self-healing ring topology without additional managed switches or proprietary hardware.
Harsh industrial environments — high-vibration press lines, chemical processing bays with corrosive atmospheres, and outdoor substations subject to wide thermal cycling — demand components engineered beyond office-grade specifications. The 1756-EN2TR/C operates reliably across 0 °C to 60 °C, draws only 3.3 W from the backplane (minimizing thermal load inside the chassis), and is available with conformal coating for elevated humidity or particulate exposure. During installation, engineers should verify chassis slot assignment in Studio 5000 Logix Designer, confirm IP addressing via BOOTP/DHCP or static assignment through RSLinx, and validate DLR supervisor configuration before commissioning ring closure — steps that prevent the majority of post-installation communication faults.
As production assets age and OEM support windows close, maintaining a verified stock of mission-critical spare modules becomes a core SRE discipline. The 1756-EN2TR/C is a high-demand legacy component; sourcing a certified original spare before failure — rather than after — eliminates the mean-time-to-repair (MTTR) penalty associated with emergency procurement and expedited freight. Treating this module as a strategic inventory item is standard practice in any Operational Excellence framework.
Key Operational Features
Device Level Ring (DLR) Supervisor: Automatic ring fault detection and traffic rerouting in <3 ms — zero operator intervention required.
Dual 10/100 Mbps Ports: Independent physical paths for simultaneous control-network and plant-network connectivity, eliminating single points of failure.
256 TCP Connection Capacity: Supports large-scale distributed I/O architectures, multi-HMI environments, and third-party EtherNet/IP device integration within a single ControlLogix system.
Seamless Integration: Native ControlLogix backplane interface — no gateway, no protocol conversion, no additional licensing required for standard EtherNet/IP I/O and produced/consumed tag communication.
High Availability Design: Conformal-coated variant available for corrosive or high-humidity environments; backplane-powered to eliminate external PSU dependency.
Firmware Remote Upgrade: Update via RSLinx Classic or FactoryTalk Linx without physical module extraction, reducing planned maintenance windows.
Maintenance & Performance Benchmarks
The 1756-EN2TR/C is engineered to serve as the communication backbone across a broad spectrum of industrial network architectures — from compact single-chassis ControlLogix cells to multi-rack, multi-zone distributed control systems spanning several hundred meters of plant floor.
In small-to-medium installations (1-3 chassis, <64 I/O nodes), the module operates comfortably in star topology using standard Cat5e infrastructure, with typical network utilization remaining below 15% under normal scan-rate conditions. In large-scale architectures — refinery distributed control, automotive body-shop automation, or water/wastewater SCADA networks — DLR ring topology is the recommended configuration, providing deterministic recovery and eliminating the cost of redundant managed switches at every segment junction.
Benchmark data from field deployments confirms that properly configured 1756-EN2TR/C rings maintain <1 ms packet latency under full 256-connection load, supporting 10 ms RPI (Requested Packet Interval) settings for time-sensitive motion and process control loops. Preventive maintenance intervals should include annual verification of port link statistics via the module’s embedded web server, firmware currency checks against Rockwell’s Product Compatibility and Download Center (PCDC), and physical inspection of RJ-45 connectors for corrosion or mechanical wear — particularly in high-vibration environments.
Comprehensive Data Sheet
| Attribute | Technical Data |
|---|---|
| Full Model Number | 1756-EN2TR/C |
| Manufacturer | Allen-Bradley (Rockwell Automation) |
| Product Family | ControlLogix 1756 Series |
| Module Type | EtherNet/IP Dual-Port Communication Bridge |
| Communication Protocol | EtherNet/IP (CIP over Ethernet) |
| Port Configuration | 2 — RJ-45, 10/100 Mbps Auto-Negotiation |
| Supported Topologies | Linear, Star, Device Level Ring (DLR) |
| Max TCP Connections | 256 |
| DLR Recovery Time | < 3 ms (single fault) |
| Backplane Power Draw | 3.3 W (typical) |
| Operating Temperature | 0 °C to 60 °C (32 °F to 140 °F) |
| Storage Temperature | -40 °C to 85 °C |
| Relative Humidity | 5% to 95% non-condensing |
| Conformal Coating | Available (Series /C designation) |
| Chassis Compatibility | All ControlLogix 1756 chassis |
| IP Address Assignment | Static, BOOTP, DHCP |
| Firmware Upgrade Method | Remote via RSLinx Classic / FactoryTalk Linx |
| Certifications | UL, CE, cUL, ATEX (zone 2) |
| Product Condition | New & Original, Factory Packaging |
| Warranty | 1 Year |
Professional Logistics & Sourcing Excellence
Every 1756-EN2TR/C unit dispatched from our inventory is supplied in original factory packaging with full manufacturer labeling, serial number traceability, and accompanying documentation. This ensures authenticity verification and simplifies incoming inspection procedures for quality-controlled facilities operating under ISO 9001 or FDA 21 CFR Part 11 frameworks.
For time-sensitive plant recovery scenarios, same-day dispatch is available on confirmed in-stock units (order cutoff times apply — contact our logistics team for current availability). We maintain dedicated global inventory of end-of-life (EOL) and legacy Rockwell Automation modules, providing a reliable supply channel for facilities operating extended asset lifecycles beyond standard OEM support windows.
Worldwide express freight options — DHL Express, FedEx International Priority, UPS Worldwide Express — are available to all major industrial regions including North America, Europe, Southeast Asia, the Middle East, and Oceania. Export documentation, commercial invoices, and HS code classification support are provided as standard to streamline customs clearance.
Engineering Support & FAQ
Q1: What are the step-by-step procedures for installing the 1756-EN2TR/C into an existing ControlLogix system?
A: Power down the chassis (or confirm hot-swap compatibility with your specific chassis revision). Insert the module into an available slot. Power up and open Studio 5000 Logix Designer — the module will appear in the I/O tree. Assign an IP address via BOOTP/DHCP server or configure static addressing through RSLinx. Add the module to the controller project, configure connection parameters (RPI, connection type), and download the updated program. Verify port link status via the module’s embedded web server before closing the maintenance window.
Q2: Which firmware versions are compatible with Studio 5000 Logix Designer v32 and above?
A: Firmware revision 5.x and above is recommended for full compatibility with Studio 5000 v32+, including support for enhanced DLR diagnostics and IPv6 addressing. Always cross-reference the Rockwell Automation Product Compatibility and Download Center (PCDC) for the specific controller firmware and software version matrix applicable to your project.
Q3: Can the 1756-EN2TR/C operate in a mixed-revision DLR ring alongside earlier /A or /B series modules?
A: Yes, the /C revision maintains backward compatibility with earlier hardware revisions within the same DLR ring. However, ring-wide DLR supervisor capabilities will default to the lowest common firmware feature set. Upgrading all nodes to /C revision and current firmware is recommended for maximum diagnostic visibility and recovery performance.
Q4: How is the warranty claim process initiated for a field-failed unit?
A: Contact our technical support team with the module serial number, purchase order reference, and a brief fault description. We will issue an RMA (Return Merchandise Authorization) number within one business day. Upon receipt and inspection of the returned unit, a replacement or repaired module is dispatched under the same express logistics terms. The 1-year warranty covers manufacturing defects and component failures under normal operating conditions.
Q5: Is it possible to use the 1756-EN2TR/C as a produced/consumed tag bridge between two ControlLogix controllers on separate subnets?
A: Yes. The module fully supports CIP-routed produced and consumed tags across subnet boundaries. Configure the producing controller’s tag with the consuming controller’s IP address as the destination path. Ensure that network infrastructure (managed switches or routers) permits CIP traffic on UDP port 2222 and TCP port 44818 between subnets.
Q6: What distinguishes the Process Optimization value of the 1756-EN2TR/C versus a standard single-port EN2T in a System Integration project?
A: In any System Integration architecture where Operational Excellence and High Availability are design requirements, the dual-port 1756-EN2TR/C eliminates the need for external redundant switch pairs at the device level. This reduces BOM cost, cabinet footprint, and failure-mode complexity — directly contributing to Process Optimization by lowering both capital expenditure and ongoing maintenance overhead for Mission-Critical Automation Components and I/O Modules across the plant network.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667
| Product Series | ControlLogix 1756 |
|---|---|
| Country of Origin | US |
Catalog Continuation
More Allen-Bradley (Rockwell) modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
Reviews
There are no reviews yet.