Original Industrial Spare Part
Allen-Bradley 1756-PA72/B ControlLogix AC Power Supply — New & Original
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU1756-PA72/B
- CategoryPLC & Industrial Automation Modules
- BrandAllen-Bradley (Rockwell)
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Allen-Bradley 1756-PA72/B ControlLogix AC Power Supply — New & Original with SKU 1756-PA72/B.
Allen-Bradley 1756-PA72/B | Reliable ControlLogix AC Power Supply — New & Original in Stock
Field Application & Operational Analysis
From the perspective of a Site Reliability Engineer managing mission-critical production assets, the Allen-Bradley 1756-PA72/B stands as a cornerstone component in sustaining system availability across ControlLogix-based automation architectures. The 1756-PA72/B delivers a wide-range 85-265V AC input with automatic voltage sensing, eliminating manual tap adjustments and dramatically reducing configuration errors during commissioning or emergency replacement scenarios. Its 10A backplane output at 5.1V DC ensures stable power distribution across multiple I/O modules, communication adapters, and processor cards — a non-negotiable requirement for process optimization in high-uptime environments.
Engineered for durability in demanding industrial conditions, this power module operates reliably across a 0°C to 60°C ambient temperature range and features 1500V AC input-to-output isolation — a critical safeguard against transient voltage spikes common in heavy manufacturing facilities. Installation requires no special tooling; the unit slots directly into any standard 1756 chassis slot and is DIN rail compatible, minimizing Mean Time to Repair (MTTR) during unplanned outages. Proper torque on terminal connections and adherence to NEC grounding standards are essential for long-term operational excellence.
As a proven automation component within the Rockwell Automation ecosystem, the 1756-PA72/B is widely stocked as a strategic spare by maintenance teams in oil & gas, automotive, food & beverage, and water treatment facilities. Holding at least one unit in reserve is a best practice for any site running ControlLogix as its primary control platform — downtime costs far exceed the cost of a spare module.
Key Operational Features
Universal AC Input (85-265V AC, 47-63 Hz): Auto-sensing voltage range supports global deployment without hardware reconfiguration.
High Backplane Current Output: 10A @ 5.1V DC sustains full chassis loading for seamless integration with dense I/O configurations.
Dual Output Rails: 10W @ 1.2A (5.1V DC) + 75W @ 5A (24V DC) for flexible system power distribution.
1500V AC Isolation: Protects sensitive control electronics from line-side disturbances — essential for mission-critical applications.
Hot-Swap Capable: Supports redundant power configurations with live replacement, enabling zero-downtime maintenance.
Multi-Certification Compliance: UL, cUL, CE, and C-Tick certified for international system integration without re-qualification.
Compact Form Factor: Fits all 1756 chassis generations — backward compatible across legacy and current ControlLogix platforms.
Maintenance & Performance Benchmarks
The 1756-PA72/B is designed to integrate into industrial network architectures of varying scale — from small standalone cells with a single 4-slot chassis to enterprise-wide distributed control systems spanning multiple racks across plant floors. Its consistent 5.1V DC backplane regulation maintains voltage within ±1% under full load, a benchmark that directly supports the timing accuracy required by high-speed motion control and safety interlock systems.
For facilities operating redundant ControlLogix configurations, this power supply pairs with Rockwell’s 1756-PSCA2 chassis adapter to enable automatic failover without process interruption. Maintenance intervals are typically aligned with annual PM cycles; however, the module’s onboard diagnostics — accessible via RSLogix 5000 / Studio 5000 — provide real-time health status, allowing condition-based maintenance strategies that extend service life and reduce unplanned failures. This level of system integration is what positions Allen-Bradley as the benchmark for automation components in regulated industries.
Comprehensive Data Sheet
| Attribute | Technical Data |
|---|---|
| Part Number / SKU | 1756-PA72/B |
| Brand | Allen-Bradley (Rockwell Automation) |
| Product Series | ControlLogix 1756 |
| Product Type | Standard AC Power Supply |
| Input Voltage Range | 85-265V AC, Auto-Sensing |
| Input Frequency | 47-63 Hz |
| Output — Backplane | 10A @ 5.1V DC (max) |
| Output — Rail 1 | 10W @ 1.2A (5.1V DC) |
| Output — Rail 2 | 75W @ 5A (24V DC) |
| Input-to-Output Isolation | 1500V AC |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Chassis Compatibility | All 1756 ControlLogix Chassis (4, 7, 10, 13, 17-slot) |
| Mounting | DIN Rail Compatible |
| Certifications | UL, cUL, CE, C-Tick |
| Country of Origin | United States |
| Condition | New & Original Factory Stock |
| Warranty | 12 Months |
Professional Logistics & Sourcing Excellence
Every unit of the 1756-PA72/B shipped from our inventory is sourced directly from authorized distribution channels and arrives in original factory packaging with full documentation, including the product datasheet and conformance certificate. For in-stock orders, same-day dispatch is available on orders confirmed before the daily cut-off time, ensuring your production line is back online with minimal delay.
We specialize in global supply for both current-production and end-of-life (EOL) / legacy modules — a critical capability for facilities maintaining older ControlLogix installations where standard distribution channels no longer carry stock. Our worldwide express logistics network covers North America, Europe, Southeast Asia, and the Middle East, with full tracking provided from dispatch to delivery. All shipments are insured and export-compliant.
Engineering Support & FAQ
Q1: What is the correct installation procedure for the 1756-PA72/B in a ControlLogix chassis?
A: Power down the chassis before installation. Align the module with the leftmost slot of the 1756 chassis, slide it in until the locking tabs engage, then connect AC input wiring to the terminal block (L1, L2/N, PE ground). Torque terminals to 0.68 N·m (6 lb·in). Restore power and verify the green PWR LED illuminates. Consult publication 1756-IN005 for full wiring diagrams.
Q2: Which firmware versions of Studio 5000 / RSLogix 5000 are compatible with this power supply?
A: The 1756-PA72/B is a hardware module with no embedded firmware; it is compatible with all versions of RSLogix 5000 and Studio 5000 Logix Designer. Diagnostics are accessible via the controller’s I/O tree in any software revision from v16 onward.
Q3: Can the 1756-PA72/B be used in a redundant power configuration?
A: Yes. When paired with the 1756-PSCA2 Power Supply Chassis Adapter and a second power supply, the system supports automatic failover. Both supplies must be installed in adjacent slots on the left side of the chassis.
Q4: What is the warranty claim process if the unit is found defective upon arrival?
A: Contact our support team at sale@ninermas.com within 7 days of receipt with your order number and a description of the fault. We will arrange priority replacement or full refund. Our 12-month warranty covers all manufacturing defects and covers return shipping for verified DOA units.
Q5: Is this power supply suitable for use in hazardous (Class I, Division 2) locations?
A: The standard 1756-PA72/B is not rated for Class I, Div 2 environments in its base configuration. For hazardous location deployments, consult Rockwell Automation’s 1756-series hazardous location documentation or contact our engineering team for guidance on appropriate enclosure solutions.
Q6: How do I verify the revision level (/B) before purchasing a replacement?
A: The revision letter is printed on the product label affixed to the module housing. When ordering, always specify the full part number including revision: 1756-PA72/B. Mixing revisions within a redundant pair is not recommended without consulting Rockwell’s compatibility matrix.
| Product Series | ControlLogix 1756 |
|---|---|
| Country of Origin | US |
Catalog Continuation
Likely ControlLogix 1756 platform matches.
These parts are closer to the same platform family signaled by the current SKU and title, so buyers can validate continuity before sending a final RFQ.
Catalog Continuation
More Allen-Bradley (Rockwell) modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 900T0272-503 HV-RP 810-495659-410 0010-13593
Semitool 900T0272-503 HV-RP Service-Ready Spare Part
SKU: A38221000 VT3-V7 B3 (DRM2) 1D10-304010-12
Edwards A38221000 Retrofit Motor Controller for Legacy Systems
Reviews
There are no reviews yet.