Original Industrial Spare Part
Allen-Bradley 1764-MM2RTC MicroLogix 1500 Memory Module with RTC — New & Original
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU1764-MM2RTC
- CategoryPLC & Industrial Automation Modules
- BrandAllen-Bradley (Rockwell)
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Allen-Bradley 1764-MM2RTC MicroLogix 1500 Memory Module with RTC — New & Original with SKU 1764-MM2RTC.
Allen-Bradley 1764-MM2RTC | Reliable Automation Component for MicroLogix 1500
Field Application & Operational Analysis
From a Site Reliability Engineer’s perspective, the Allen-Bradley 1764-MM2RTC is one of the most operationally decisive components in a MicroLogix 1500 control architecture. Its 16 KB non-volatile EEPROM memory, combined with a battery-backed real-time clock, directly elevates system availability by enabling time-stamped fault logging, scheduled process triggers, and deterministic program execution — all without dependency on external timekeeping infrastructure. In mission-critical automation environments, the 1764-MM2RTC functions as the backbone of process optimization, ensuring that production sequences remain synchronized even through power interruptions or controller resets.
Engineered for harsh industrial conditions, this module withstands operating temperatures from 0°C to 60°C and installs via a keyed, hot-swappable connector that eliminates mis-seating risk during live maintenance windows. Field technicians consistently report that the module’s plug-and-play compatibility with RSLogix 500 software reduces commissioning time significantly — a critical advantage when system integration timelines are compressed. Proper installation requires no external wiring or DIP switch configuration, minimizing human error during replacement procedures.
As production lines age and OEM support windows close, maintaining a certified stock of the 1764-MM2RTC as a spare part is no longer optional — it is a core tenet of operational excellence. EOL (End-of-Life) procurement risk is real, and a single unplanned downtime event caused by an unavailable memory module can far exceed the cost of maintaining strategic inventory reserves.
Key Operational Features
16 KB Non-Volatile EEPROM Storage — Retains ladder logic, data files, and configuration parameters without external power, supporting high availability across power cycling events.
Battery-Backed Real-Time Clock (RTC) — Maintains timekeeping accuracy within ±2 minutes/month; critical for time-stamped event logs and scheduled I/O module operations.
Seamless System Integration — Plug-and-play compatibility with MicroLogix 1500 series (1764-24AWA, 1764-24BWA, 1764-28BXB, 1764-LRP); auto-recognized by RSLogix 500.
Redundancy-Ready Architecture — Supports complex ladder programs with extended data tables, enabling redundant logic paths for fault-tolerant process control.
Hot-Swappable Keyed Connector — Engineered for zero-error field replacement, reducing MTTR and supporting live maintenance without full system shutdown.
Mission-Critical Compliance — Meets Rockwell Automation’s industrial-grade manufacturing standards; factory-tested prior to shipment.
Maintenance & Performance Benchmarks
The 1764-MM2RTC is architected to serve as a scalable memory and timekeeping solution across diverse industrial network topologies. In small-scale standalone deployments, it provides sufficient program storage for single-station PLC control with time-based scheduling. In mid-scale distributed architectures, multiple MicroLogix 1500 controllers equipped with the 1764-MM2RTC can be synchronized via DeviceNet or Ethernet/IP gateways, enabling coordinated I/O module management across production zones.
For large-scale facilities integrating legacy MicroLogix infrastructure with modern SCADA or DCS platforms, the module’s EEPROM retention capability ensures that program integrity is preserved during network reconfiguration events — a key factor in process optimization initiatives. Maintenance intervals for the internal lithium battery are typically 5-7 years under standard operating conditions, with battery replacement procedures documented in Rockwell Automation publication 1764-IN001.
Comprehensive Data Sheet
| Attribute | Technical Data |
|---|---|
| Part Number / SKU | 1764-MM2RTC |
| Brand / Manufacturer | Allen-Bradley (Rockwell Automation) |
| Product Series | MicroLogix 1500 |
| Product Type | PLC Memory Module with Real-Time Clock |
| Memory Capacity | 16 KB Non-Volatile EEPROM |
| Real-Time Clock Accuracy | ±2 minutes per month (battery-backed) |
| Compatible Controllers | 1764-24AWA, 1764-24BWA, 1764-28BXB, 1764-LRP |
| Programming Software | RSLogix 500 (auto-recognition) |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Storage Temperature | -40°C to 85°C |
| Installation Method | Hot-swappable, keyed connector |
| Data Retention | Without power (EEPROM non-volatile) |
| Battery Type | Pre-installed lithium (5-7 year service life) |
| Certifications | UL, CE, RoHS compliant |
| Country of Origin | United States |
| Condition | New & Original Factory Sealed |
Professional Logistics & Sourcing Excellence
Every 1764-MM2RTC unit dispatched from our facility is sourced directly from authorized distribution channels and ships in original factory packaging with full traceability documentation. For automation components classified as End-of-Life (EOL) or legacy modules, our global supply network maintains certified stock to support long-running production lines that cannot be easily migrated to newer controller platforms.
Original Factory Packaging — Anti-static protection, factory labels, and serial number traceability intact.
Same-Day Dispatch — Available for in-stock units when orders are confirmed before daily cut-off time.
Worldwide Express Logistics — DHL, FedEx, and UPS international shipping to over 150 countries.
EOL & Legacy Module Supply — Dedicated sourcing desk for discontinued Rockwell Automation automation components.
1-Year Warranty — Covers manufacturing defects; replacement or full refund guaranteed.
Engineering Support & FAQ
Q1: How do I install the 1764-MM2RTC into a MicroLogix 1500 controller?
Power down the MicroLogix 1500 base unit (or use the hot-swap procedure if supported). Align the keyed connector on the 1764-MM2RTC with the memory module slot on the controller’s left side. Press firmly until the module seats fully. Power up the controller — RSLogix 500 will automatically detect the expanded memory and RTC functions. No additional configuration is required.
Q2: Which firmware versions of MicroLogix 1500 are compatible with the 1764-MM2RTC?
The 1764-MM2RTC is compatible with all MicroLogix 1500 firmware revisions from Series A onward. For optimal RTC synchronization features, Rockwell Automation recommends firmware revision 7 or higher. Verify your controller’s firmware version via RSLogix 500 under Controller Properties > General.
Q3: Can the 1764-MM2RTC be used to transfer programs between MicroLogix 1500 controllers?
Yes. The EEPROM memory on the 1764-MM2RTC supports program store and load operations. A program saved to the module from one MicroLogix 1500 controller can be loaded into another compatible controller of the same series, making it an effective tool for rapid field replacement and system integration workflows.
Q4: What is the warranty claim process for a defective 1764-MM2RTC unit?
Contact our technical support team at sale@ninermas.com with your order number, a description of the fault symptom, and photographic evidence of the module condition. Our team will initiate an RMA (Return Merchandise Authorization) within 24 business hours. Replacement units are dispatched upon receipt and inspection of the returned module, with express shipping at no additional cost.
Q5: How long does the internal RTC battery last, and can it be replaced?
Under standard operating conditions (0°C 60°C), the pre-installed lithium battery maintains RTC function for 5-7 years. Battery replacement is documented in Rockwell Automation publication 1764-IN001. Use only the manufacturer-specified replacement battery to ensure continued RTC accuracy and module warranty validity.
Q6: Is the 1764-MM2RTC still available as a new part, or is it an EOL product?
The 1764-MM2RTC has been classified as a mature/legacy product by Rockwell Automation. However, our global sourcing network maintains certified new-in-box inventory to support ongoing production lines. Contact us directly for current stock availability and lead time confirmation before placing critical orders.
| Product Series | AB Allen-Bradley Parts & Accessories |
|---|---|
| Country of Origin | US |
Catalog Continuation
More Allen-Bradley (Rockwell) modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 3402230500 34003816XD-1DA 34003816XD-6DA 0006230138B3
INMC 3402230500 Retrofit-Compatible I/O Module for Legacy Systems
SKU: 03601-54-080 03601-34-080
IEE 03601-54-080 Retrofit-Compatible Display for Legacy Systems
SKU: INFO-4KP 94161
Reviews
There are no reviews yet.