Original Industrial Spare Part

MITSUBISHI MY41 Service-Ready Spare Part for Industrial Maintenance

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: MY41 PLC & Industrial Automation Modules Mitsubishi

RFQ Ready

Pricing by RFQ

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

MITSUBISHI MY41 Service-Ready Spare Part for Industrial Maintenance

The MITSUBISHI MY41 is a general-purpose miniature relay module widely deployed across MELSEC PLC-based control cabinets, machine tool panels, and industrial automation systems. As a service-ready original spare part, the MY41 is engineered for direct drop-in replacement in high-cycle switching applications where contact reliability and coil response consistency are critical to maintaining uptime. Whether you are managing a scheduled annual overhaul, responding to an unplanned line stoppage, or building a preventive maintenance spare parts kit, the MY41 delivers the switching performance and dimensional compatibility that maintenance engineers depend on.

At NINERMAS, every MY41 unit is sourced from verified supply channels, individually inspected, and function-tested prior to dispatch. We maintain buffer stock to support both emergency single-unit orders and long-term blanket purchase agreements for facilities running MITSUBISHI relay-based control architectures across multiple production lines or plant sites.

Spare Maintenance Table

Parameter Specification
Model / SKU MY41
Brand MITSUBISHI
Series MY Series (General-Purpose Miniature Relay)
Product Type Relay Module / Electromechanical Relay
Coil Voltage Options AC 100–120V / AC 200–240V / DC 6V / DC 12V / DC 24V / DC 48V / DC 100–110V (specify on order)
Contact Configuration 4PDT (4 Pole Double Throw) — 4NO + 4NC
Contact Rating 5A at 250V AC / 5A at 30V DC (resistive load)
Mechanical Life ≥ 10,000,000 operations
Electrical Life ≥ 100,000 operations (rated load)
Mounting Socket / DIN Rail via MY4Z or equivalent socket base
Dimensions (W×H×D) Approx. 28 × 36 × 36 mm (socket-mounted)
Operating Temperature -40°C to +70°C
Insulation Resistance ≥ 1000 MΩ (500V DC)
Dielectric Strength 2000V AC (1 min, between coil and contacts)
Ingress Protection IP40 (relay body)
Compatibility MELSEC FX, Q, iQ-R series PLC output relay circuits; general control cabinet relay logic
Application Environment Machine tools, conveyor systems, packaging lines, HVAC control panels, motor control centers
Origin Japan
Warranty 12 Months from date of shipment (NINERMAS)
Availability In Stock — Ready to Ship

Maintenance Planning for Continuous Operation

When a MY41 relay reaches end-of-life or exhibits contact chatter, coil overheating, or intermittent switching faults, the replacement procedure should be treated as an opportunity for a broader control cabinet health check. Maintenance engineers should simultaneously inspect the MY4Z or MY4ZN socket base for contact oxidation, pin deformation, or heat discoloration — a degraded socket will shorten the service life of a new relay regardless of its quality.

In MELSEC FX3U or Q-series PLC panels, the MY41 is commonly wired into the output relay circuit alongside the FX3U-32MT/ES output module or Q02UCPU digital output cards. If the relay is switching inductive loads such as solenoid valves or motor contactors, verify that the surge suppressor or RC snubber circuit across the load coil is intact — a failed snubber accelerates contact erosion on the MY41 and can introduce voltage spikes that affect adjacent I/O modules.

Power supply integrity is equally important. The MY41 coil draws from the 24V DC control power rail in most installations. Inspect the MITSUBISHI Q61P or Q62P power supply module output voltage under load, and check the terminal block connections on the DIN rail for loose crimps or corrosion. A voltage sag on the 24V rail can cause relay dropout under high-load conditions, mimicking a faulty relay when the root cause is upstream.

For facilities running MITSUBISHI GOT2000 series HMI panels alongside MELSEC PLCs, relay status bits are often mapped to HMI alarm screens. After replacing a MY41, confirm that the corresponding M-device or Y-device bit in the PLC ladder logic is resetting correctly and that the GOT2000 alarm history is cleared to avoid false maintenance alerts on the next shift.

In multi-axis servo systems using MITSUBISHI MR-J4 or MR-JE servo amplifiers, the MY41 is frequently used in the servo-ready interlock and emergency stop relay chain. When replacing the relay in this circuit, verify the servo amplifier’s CN1 connector wiring and confirm that the EM2 (forced stop) input signal is functioning correctly before re-enabling the servo drive. Also inspect the nearby terminal blocks, fuse holders (typically 2A–5A glass fuses for control circuits), and any signal isolators in the safety relay chain.

For annual maintenance planning, consider stocking the MY41 alongside the MY2 and MY4 variants to cover different pole configurations across your relay panel. Facilities with high-cycle applications — such as packaging or stamping lines — should target a 12-month proactive replacement interval for all MY-series relays in critical switching positions, regardless of observed fault symptoms.

Site Replacement Workflow

Step 1 — Isolation: De-energize the control cabinet section containing the MY41. Lock out / tag out (LOTO) the relevant circuit breaker. Confirm zero voltage on the relay coil terminals using a calibrated multimeter.

Step 2 — Documentation: Photograph the existing relay wiring and socket orientation before removal. Note the coil voltage marking on the existing MY41 body to confirm the replacement unit matches exactly.

Step 3 — Socket Inspection: Remove the old MY41 from the MY4Z socket. Inspect socket contacts for oxidation or deformation. Clean with contact cleaner if necessary. Replace the socket if contact resistance exceeds acceptable limits.

Step 4 — Installation: Insert the new MY41 into the socket, ensuring the alignment key is correctly oriented. Apply firm, even pressure until the relay body clicks into the socket retention clip.

Step 5 — Verification: Re-energize the circuit. Use the PLC’s forced output function (in MELSEC GX Works2 or GX Works3) to energize the relay coil and verify contact switching with a continuity tester or the HMI I/O monitor screen.

Step 6 — Documentation Update: Record the replacement in the equipment maintenance log, including the date, technician ID, new relay serial number, and next scheduled inspection date. Update the spare parts inventory system to trigger a reorder if buffer stock falls below the minimum threshold.

This workflow minimizes downtime to under 30 minutes for a single relay replacement and ensures system compatibility is maintained without requiring PLC program modifications. The MY41’s direct socket-mount design eliminates rewiring risk and supports fast, error-free field replacement even in high-density relay panels.

Spare Parts Support FAQ

Q1: How do I confirm the correct coil voltage variant of the MY41 for my installation?
Check the coil voltage marking printed on the side of the existing relay body (e.g., MY41-D24 for 24V DC). If the original relay is no longer readable, refer to the control cabinet wiring diagram or the PLC I/O assignment sheet. NINERMAS can assist with cross-referencing the part number if you provide the cabinet model and application details.

Q2: Is the MY41 compatible with third-party socket bases, or must I use the MITSUBISHI MY4Z socket?
The MY41 is designed for use with the MITSUBISHI MY4Z or MY4ZN socket base. While some third-party sockets with identical pin geometry may be physically compatible, NINERMAS recommends using genuine MITSUBISHI socket bases to ensure rated contact resistance and mechanical retention. Mixing relay and socket brands can void warranty coverage and introduce reliability risks in safety-critical circuits.

Q3: What testing does NINERMAS perform before shipping the MY41?
Each MY41 unit undergoes coil continuity verification, insulation resistance check, and contact switching function test prior to dispatch. Units are shipped in anti-static packaging with individual inspection records. Our 12-month warranty covers manufacturing defects and premature failure under normal operating conditions from the date of shipment.

Q4: Can NINERMAS support long-term supply agreements for the MY41 and related MITSUBISHI relay components?
Yes. NINERMAS offers blanket purchase agreements and scheduled delivery programs for facilities requiring ongoing supply of MY41 and related components such as the MY2, MY4, and MY-series socket bases. Long-term agreements include price stability commitments, priority allocation during supply constraints, and dedicated account support. Contact our sales team to discuss your annual consumption volume and lead-time requirements.

Product Series

MELSEC

Country of Origin

JP

Catalog Continuation

More Mitsubishi modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack