(0 reviews)
Manufacturer:
Triconex (Schneider Electric)
Product No.:
1400010-001
Condition:
1000 in stock
Product Type:
Tricon v9/v10/v11
Product Origin:
CN
Payment:
T/T, Western Union
Weight:
1.00g
Shipping port:
Xiamen
Warranty:
12 months


Share:

Description

Triconex 1400010-001 Industrial Lithium Battery (High-Reliability Power Backup Solution)

The Triconex 1400010-001 represents a mission-critical power backup solution engineered for safety instrumented systems in hazardous industrial environments. This genuine Schneider Electric lithium battery delivers uninterrupted memory retention and real-time clock functionality for Tricon and Trident safety controllers, ensuring your emergency shutdown systems remain operational during power anomalies.

Designed for process industries where safety system failure is not an option, this battery addresses the fundamental challenge of maintaining controller state integrity during utility power interruptions. Plant engineers and safety managers rely on the 1400010-001 to protect against data loss in oil refineries, chemical plants, power stations, and pharmaceutical facilities where SIL 3-rated protection is mandatory.

With field-proven reliability across extreme temperature ranges and hot-swap capability that eliminates planned downtime, this battery delivers both operational continuity and maintenance flexibility. The 3.6V lithium cell technology provides superior energy density compared to traditional backup solutions, extending replacement intervals and reducing total cost of ownership.

Core Features & Technical Advantages

→ Extended Service Life Architecture
5+ year operational lifespan minimizes replacement frequency and maintenance labor costs while ensuring consistent voltage delivery throughout the battery lifecycle.

→ Hot-Swappable Installation Design
Replace batteries during live operation without system shutdown, controller reset, or safety function interruption—critical for continuous process industries with zero-tolerance downtime requirements.

→ Extreme Environment Performance
Operates reliably from -40°C to +85°C, accommodating outdoor installations, unheated enclosures, and high-temperature process areas where conventional batteries fail.

→ SIL 3 Safety Certification
IEC 61508 compliant design meets the highest safety integrity level requirements for emergency shutdown systems, fire & gas detection, and burner management applications.

✓ Genuine OEM Quality Assurance
Factory-tested Schneider Electric component with full traceability, eliminating counterfeit risks and ensuring compatibility with all Triconex controller firmware revisions.

✓ Integrated Diagnostic Monitoring
TriStation software provides real-time battery health status, voltage trending, and predictive low-voltage alerts for proactive replacement scheduling.

Industrial Application Scenarios

Upstream Oil & Gas Production
Emergency shutdown systems on offshore platforms and wellhead facilities require absolute reliability during power transients. The 1400010-001 maintains ESD logic solver memory during generator switchovers and utility failures, preventing spurious trips that cost $500K+ per incident in lost production.

Chemical Process Safety Systems
Reactor protection and critical alarm systems in chemical plants demand continuous operation. This battery preserves controller configuration and process state data during planned maintenance or unexpected power events, ensuring safety functions remain armed and ready.

Power Generation Turbine Control
Gas and steam turbine safety systems use Triconex controllers for overspeed protection and emergency trip functions. Battery backup prevents controller resets during black-start sequences and grid disturbances, maintaining protection availability at all times.

Pharmaceutical Clean Room Controls
Environmental monitoring and critical process control in GMP-regulated facilities require validated system uptime. The 1400010-001 supports 21 CFR Part 11 compliance by preventing data loss during power quality events.

Manufacturing Machine Safety
Automated production lines with safety-rated PLCs protecting personnel from robotic cells and high-speed machinery rely on battery backup to maintain safety logic during power interruptions, preventing unsafe restart conditions.

Technical Parameters & Selection Guide

ParameterSpecification
Part Number1400010-001
Battery ChemistryLithium Primary Cell (Non-rechargeable)
Nominal Voltage3.6V DC
Memory Retention Duration30-90 days (configuration dependent)
Operating Temperature-40°C to +85°C (-40°F to +185°F)
Storage Temperature-40°C to +60°C
Expected Service Life5+ years (typical industrial conditions)
Replacement IndicatorTriStation diagnostic alarm
Compatible ControllersTricon (all versions), Trident
Safety CertificationSIL 3 per IEC 61508
Physical DimensionsStandard Triconex battery form factor
Installation MethodPlug-in connector (hot-swappable)

Selection Criteria: Choose the 1400010-001 for all Triconex safety controller applications requiring backup power. This is the only approved battery for Tricon and Trident systems. Verify your controller chassis has accessible battery compartment. For systems operating continuously above 70°C ambient, consider enhanced ventilation to maximize battery lifespan. Plan replacement every 3-5 years based on TriStation health monitoring rather than fixed calendar schedules.

Extended Functionality & Integration

Predictive Maintenance Integration: Battery voltage and health data integrates with plant asset management systems via Modbus or OPC interfaces from the Triconex controller, enabling condition-based maintenance strategies and automated work order generation.

Redundant Power Architecture: Combine with dual Triconex power supply modules (8311, PS4144110) for complete power system redundancy, ensuring safety functions remain available during single-point power supply failures or battery replacement activities.

Compliance Documentation: Each battery ships with material certificates and test reports supporting IEC 61508, ATEX, and hazardous location certifications required for safety system validation and regulatory audits.

Delivery Timeline & Service Guarantee

Standard Delivery: 3-5 business days for in-stock units via express courier with tracking
Custom Orders: 2-3 weeks for bulk quantities or special packaging requirements
Warranty Coverage: 12-month manufacturer warranty against defects in materials and workmanship
Technical Support: Pre-sales compatibility verification, installation guidance, and troubleshooting assistance
Documentation Included: Installation instructions, safety data sheet (SDS), certificate of conformity, and disposal guidelines

Frequently Asked Questions

What is the typical backup duration for Triconex controller memory with this battery?
The 1400010-001 provides 30-90 days of memory retention depending on controller model, I/O configuration density, and ambient temperature. Higher temperatures and larger I/O counts reduce backup duration. TriStation software displays estimated remaining backup time.

Can the battery be replaced without shutting down the safety system?
Yes, the battery features hot-swap capability. Replace during normal operation without interrupting safety functions, controller logic execution, or I/O scanning. The controller continues operating on main power during the 30-60 second replacement procedure.

How do I know when battery replacement is required?
TriStation 1131 software generates a "Low Battery" diagnostic alarm when voltage drops below threshold (typically 3.0V). Monitor battery health in the controller diagnostics screen. We recommend proactive replacement every 3-5 years or when voltage trends indicate degradation.

Is this battery compatible with legacy Tricon systems installed in the 1990s?
Yes, the 1400010-001 is backward compatible with all Tricon controller generations from initial release through current Trident systems. The battery connector and voltage specifications have remained consistent across all Triconex safety controller platforms.

What are the proper disposal procedures for lithium batteries?
Lithium primary cells require disposal through certified battery recycling facilities per local environmental regulations. Do not incinerate or dispose in regular waste. Contact your regional hazardous waste management authority for approved recycling locations. Many industrial battery suppliers offer take-back programs.

Does the battery require any configuration or programming after installation?
No configuration required. The battery is a plug-and-play component. After installation, verify the "Low Battery" alarm clears in TriStation diagnostics. The controller automatically begins using the new battery for memory backup without any programming changes.

Take the Next Step

Ensure uninterrupted safety system operation with genuine Triconex battery backup. Contact our technical team for compatibility verification, bulk pricing, or integration with your existing power redundancy architecture. We provide same-day quotations and can coordinate delivery with your planned maintenance windows.

Request a Quote: sale@ninermas.com | +0086 187 5021 5667


© 2026 NINERMAS COMPANY LIMITED. All rights reserved.
Original Source: https://ninermas.com
Contact: sale@ninermas.com | +0086 187 5021 5667