- SKUQUINT-PS/1AC/24DC/40
- CategoryTSI & Rotating Machinery Monitoring
- BrandPhoenix Contact
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: PHOENIX CONTACT QUINT-PS/1AC/24DC/40 | Industrial Retrofit Power Supply 24V 40A with SKU QUINT-PS/1AC/24DC/40.
PHOENIX CONTACT QUINT-PS/1AC/24DC/40 — Professional Retrofit & System Upgrade Component
System Modernization & Migration Analysis
As a Retrofit Project Lead overseeing industrial power infrastructure upgrades across global manufacturing sites, I consistently identify the PHOENIX CONTACT QUINT-PS/1AC/24DC/40 as a cornerstone component in system modernization programs. This 960W, 24V DC / 40A DIN-rail power supply unit is not merely a replacement part — it is a strategic enabler that extends the operational lifespan of aging control architectures while simultaneously elevating system reliability to modern industrial standards. Its Preventive Function Monitoring (PFM) technology transforms reactive maintenance into predictive lifecycle management, a critical shift for facilities transitioning from legacy SCADA and PLC environments.
The PHOENIX CONTACT QUINT-PS/1AC/24DC/40 excels as a hardware upgrade anchor within legacy compatibility frameworks. Its universal 100-240V AC input eliminates the need for costly input-side transformer replacements when migrating from older regional voltage standards. The adjustable 24V DC output (22-28V) accommodates the voltage tolerance bands of first-generation PLCs and field devices that remain in service during phased migration projects. This backward compatibility is precisely what retrofit project leads require: a performance enhancement that does not force a full system cutover.
From a migration risk and cost perspective, deploying the QUINT-PS/1AC/24DC/40 as the power backbone of a retrofit project significantly reduces both capital expenditure and schedule risk. Its Selective Fuse Breaking (SFB) technology isolates downstream faults without tripping upstream circuit breakers, protecting the integrity of the broader control system during the transition period. The result is a seamless integration pathway that keeps production running while the modernization program advances in parallel.
Upgrade Highlights & Compatibility
✅ Universal Input Voltage (100-240V AC ±15%): Eliminates input-side infrastructure changes during cross-regional system migrations — deploy globally without derating.
50A Peak Surge Capacity (5 sec): Handles inrush currents from legacy actuators, solenoids, and motor starters that older PSUs could not sustain — a direct performance enhancement over first-generation supplies.
✅ Preventive Function Monitoring (PFM): Shifts maintenance strategy from reactive to predictive — critical for legacy systems where unplanned downtime carries the highest cost.
Selective Fuse Breaking (SFB): Fault isolation without upstream tripping — protects the entire control panel during retrofit commissioning phases.
✅ Conformal Coating Option: Future-proofs installations in corrosive, high-humidity, or dusty environments where legacy open-frame supplies have historically failed prematurely.
Parallel & Redundancy Ready: Native support for N+1 redundancy configurations via QUINT-ORING modules — a seamless integration path toward zero-downtime architectures.
✅ Wide Operating Temperature (-25°C to +70°C): Maintains full-rated output across the thermal extremes common in legacy plant environments lacking modern HVAC infrastructure.
Modernization Use Cases & Success Stories
DCS Power Infrastructure Overhaul — Chemical Processing Plant:
A regional chemical facility operating a 15-year-old Distributed Control System (DCS) faced chronic power supply failures causing unplanned shutdowns averaging 18 hours per incident. The retrofit solution centered on replacing aging 24V DC supplies with the QUINT-PS/1AC/24DC/40 across 12 control cabinets. The PFM early-warning system eliminated surprise failures within the first operational quarter, and the SFB feature prevented three potential cascade fault events during the transition commissioning period. The performance upgrade delivered a measurable reduction in maintenance labor costs and restored production schedule confidence.
Turbine Supervisory Instrumentation (TSI) System Migration — Power Generation Facility:
A gas turbine operator required a hardware upgrade to the 24V DC power distribution layer of its TSI system without interrupting continuous monitoring obligations. The QUINT-PS/1AC/24DC/40’s hot-swap capability (when paired with QUINT-ORING redundancy modules) enabled a live cutover with zero monitoring gaps. The adjustable output voltage allowed fine-tuned compatibility with legacy Bently Nevada vibration monitoring modules still in service, demonstrating exceptional legacy compatibility during a phased system migration spanning 14 months.
Automotive Assembly Line Retrofit — Multi-Site Standardization:
A Tier-1 automotive supplier standardized on the QUINT-PS/1AC/24DC/40 across 8 global manufacturing sites as part of a control system harmonization initiative. The universal input voltage range eliminated site-specific PSU variants, reducing spare parts inventory by 60% and simplifying the global logistics footprint — a direct operational performance enhancement with measurable ROI within the first year of deployment.
Migration Technical Data Sheet
| Feature / Property | Upgrade Value |
|---|---|
| Full Model Number | PHOENIX CONTACT QUINT-PS/1AC/24DC/40 |
| Input Voltage Range | 100-240V AC (±15%), 50/60 Hz — universal global compatibility |
| Output Voltage | 24V DC, adjustable 22-28V for legacy device tolerance matching |
| Rated Output Current | 40A continuous |
| Peak Surge Current | 50A for 5 seconds — handles legacy inrush loads |
| Power Rating | 960W |
| Efficiency | >94% at full load — reduces heat vs. legacy linear supplies |
| Mounting Standard | 35mm DIN rail (EN 60715) — direct retrofit fit in existing cabinets |
| Operating Temperature | -25°C to +70°C — full rating in legacy plant thermal environments |
| Protection Features | Overload, short-circuit, overvoltage, overtemperature |
| Fault Isolation Technology | Selective Fuse Breaking (SFB) — protects upstream breakers during retrofit |
| Predictive Maintenance | Preventive Function Monitoring (PFM) — early aging detection |
| Redundancy Support | Parallel operation with QUINT-ORING modules — N+1 architecture ready |
| Environmental Protection | Conformal coating available — corrosion and humidity resistance |
| Certifications | UL, cUL, CE, GL, DNV — multi-industry and marine compliance |
| Dimensions (W H D) | 125 — 124 — 120 mm — standard cabinet footprint |
| Weight | 3.3 kg |
| Lifecycle Status | Active — current production, full manufacturer support |
Supply Chain & Deployment Support
Original & Factory Sealed Stock:
All QUINT-PS/1AC/24DC/40 units are sourced as genuine PHOENIX CONTACT product, factory sealed with full manufacturer traceability documentation. No refurbished, reconditioned, or gray-market inventory — critical assurance for retrofit projects where component authenticity directly impacts system certification and warranty validity.
Expedited Global Logistics:
Recognizing that retrofit and migration projects operate on compressed timelines, we maintain ready stock with expedited international shipping to support urgent deployment schedules across Asia-Pacific, Europe, the Americas, and the Middle East. DHL Express, FedEx Priority, and freight consolidation options are available to match your project logistics requirements.
Technical Support for Obsolete & Legacy Hardware Integration:
Our engineering support team specializes in legacy compatibility challenges — from matching output voltage profiles to aging field devices, to advising on cabinet layout modifications for DIN-rail retrofit installations. We provide pre-sales application consultation and post-delivery commissioning guidance to ensure your system migration proceeds without technical obstacles.
Retrofit FAQ — Upgrade Guide
Q1: Will the QUINT-PS/1AC/24DC/40 physically fit in my existing control cabinet without structural modifications?
A: The unit mounts on standard 35mm DIN rail (EN 60715), which is the universal mounting standard across virtually all industrial control cabinets manufactured since the 1980s. At 125mm wide, it occupies the same footprint as most legacy 40A-class DIN-rail supplies. In most retrofit scenarios, it is a direct mechanical replacement requiring no cabinet structural changes — only terminal rewiring.
Q2: How does this unit communicate with older PLC and DCS systems that lack modern fieldbus interfaces?
A: The QUINT-PS/1AC/24DC/40 provides a DC OK relay contact output (potential-free) that interfaces directly with legacy digital input modules on any PLC or DCS platform — including older Siemens S5, Allen-Bradley PLC-5, and Honeywell TDC 3000 systems. No fieldbus or protocol conversion is required. For advanced monitoring integration, the optional QUINT-PS/1AC/24DC/40/CO2 variant adds CO signaling for building management system connectivity.
Q3: Can this PSU serve as a direct replacement for aging legacy power supplies from other manufacturers?
A: Yes. The adjustable output voltage (22-28V DC) and universal input range make the QUINT-PS/1AC/24DC/40 a viable hardware upgrade replacement for legacy 24V DC supplies from Siemens, ABB, Schneider Electric, Murr Elektronik, and other manufacturers. Verify the legacy unit’s output current rating and terminal configuration before substitution. Our technical team can assist with cross-reference validation for specific legacy models.
Q4: What is the recommended approach for migrating from a single large PSU to a distributed QUINT architecture?
A: The preferred retrofit solution is a phased migration: first, install the QUINT-PS/1AC/24DC/40 in parallel with the existing supply using a QUINT-ORING redundancy module to validate performance under live load. Once confirmed stable, decommission the legacy unit. This approach eliminates production downtime risk and provides a validation window before full cutover — the hallmark of a professional system migration strategy.
Q5: How does the PFM early-warning system integrate with existing plant alarm management infrastructure?
A: The PFM output is a potential-free relay contact that can be wired directly into any legacy alarm annunciator panel, DCS alarm input, or SCADA digital input card. No software configuration is required on the PSU side. This seamless integration with existing alarm infrastructure is a key advantage for retrofit projects where modifying the alarm management system is outside project scope.
Q6: What backup or spare parts strategy is recommended for sites running the QUINT-PS/1AC/24DC/40 in critical applications?
A: For mission-critical applications, we recommend maintaining one cold-standby unit per 4-6 installed units, stored in original factory packaging. Given the QUINT-PS/1AC/24DC/40’s Active lifecycle status and PHOENIX CONTACT’s long-term product support commitment, spare parts availability is assured for the foreseeable future. For sites with legacy obsolete supplies, transitioning to the QUINT platform also consolidates spare parts inventory — a direct operational cost reduction.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667
| Product Series | Other Legacy / Discontinued Modules |
|---|---|
| Country of Origin | US |
Catalog Continuation
More Phoenix Contact modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: QUINT-ORING/24DC/2X10/1X20
Phoenix Contact QUINT-ORING/24DC/2X10/1X20 | Active Redundancy Module – Original Spare Parts
Catalog Continuation
Alternative parts within TSI & Rotating Machinery Monitoring.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 51305980-184 REVB
Honeywell 51305980-184 REVB | TDC 3000 Industrial Cable Assembly
SKU: 51307599-176 REVA
Honeywell 51307599-176 REV A | TDC 3000 DCS Cable Assembly