Original Industrial Spare Part
GE IS200VTURH2BAC Service-Ready Spare Part for Industrial Maintenance
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUIS200VTURH2BAC
- CategoryPLC & Industrial Automation Modules
- BrandGE
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: GE IS200VTURH2BAC Service-Ready Spare Part for Industrial Maintenance with SKU IS200VTURH2BAC.
GE IS200VTURH2BAC Service-Ready Spare Part for Industrial Maintenance
The GE IS200VTURH2BAC is a critical turbine control board designed for use within the GE Mark VI Turbine Control System — one of the most widely deployed distributed control architectures in gas turbine, steam turbine, and combined-cycle power generation facilities worldwide. As aging Mark VI installations continue to operate beyond their original design lifecycle, the availability of service-ready, pre-tested spare parts such as the IS200VTURH2BAC becomes a decisive factor in plant uptime, maintenance planning, and capital expenditure control.
At NINERMAS, every IS200VTURH2BAC unit is sourced from verified supply channels, subjected to pre-shipment functional testing, and dispatched with a 12-month warranty. Our inventory program is designed to support both emergency breakdown replacements and planned annual maintenance shutdowns, ensuring that procurement engineers and maintenance teams can secure stock with confidence — regardless of whether the original equipment manufacturer still supports the part.
The IS200VTURH2BAC board interfaces directly with the Mark VI I/O and control architecture. In turbine control environments, this module plays a role in signal conditioning, protection logic, and inter-board communication within the Mark VI control cabinet. When this board fails or degrades, the consequences can include turbine trip events, loss of protection coverage, and extended unplanned outages. Rapid replacement with a tested, compatible spare is the most effective strategy for restoring normal operation.
Spare Maintenance Table
| Parameter | Specification / Detail |
|---|---|
| Part Number | IS200VTURH2BAC |
| Brand | GE (General Electric) |
| Series | Mark VI Turbine Control System |
| Product Type | Turbine Control Board / I/O Interface Module |
| Application | Gas Turbine, Steam Turbine, Combined-Cycle Power Plants |
| Compatibility | GE Mark VI Control System; compatible with IS200 series boards |
| Origin | United States |
| Installation Environment | Industrial control cabinet; DIN rail or backplane-mounted |
| Operating Temperature | 0°C to 60°C (typical industrial control room range) |
| Pre-Shipment Testing | Yes — functional verification prior to dispatch |
| Warranty | 12 Months from date of shipment |
| Lead Time | Subject to stock availability; express dispatch available |
| Condition | Original / Refurbished-Tested (confirmed at order) |
| Long-Term Supply | Yes — lifecycle extension program available |
| Contact | sale@ninermas.com | +0086 187 5021 5667 |
Maintenance Planning for Continuous Operation
Replacing the IS200VTURH2BAC in a Mark VI control cabinet is rarely an isolated task. Experienced maintenance engineers understand that a board-level failure in a turbine control system is often a symptom of broader electrical stress, aging interconnects, or degraded power quality within the same control enclosure. A thorough replacement workflow should include inspection and, where necessary, simultaneous replacement of adjacent components.
Begin with the Mark VI power supply modules — units such as the IS200EPCTG1A or equivalent PPDA/PPDB power distribution boards — which regulate DC bus voltage to all I/O and control boards. A failing or marginal power supply can cause intermittent board faults that mimic hardware failure. Verify output voltage stability under load before reinstalling the IS200VTURH2BAC.
Next, inspect the Mark VI backplane and VME rack assembly. The IS200VTURH2BAC connects to the system via backplane edge connectors; oxidized or mechanically stressed connector pins are a common root cause of communication faults. Clean and inspect all backplane slots adjacent to the replaced board.
Review the I/O terminal boards connected to the VTURH module — including associated IS200 series I/O boards such as the IS200TBCIH1C or IS200TBAIH1C — for signs of thermal stress, loose wiring, or corroded terminals. These boards carry analog and digital signals between field instruments and the control processor; degraded connections here can cause false trips or missed protection events.
Check the communication interface modules within the Mark VI cabinet, including any IONET or Ethernet communication boards (e.g., IS200IOCIH1A), which handle inter-controller data exchange. A board replacement event is an ideal time to verify firmware versions and communication health across the control network.
For plants using redundant Mark VI controllers (R, S, T voting architecture), confirm that all three controller boards are synchronized and that the replacement IS200VTURH2BAC is correctly configured for its designated controller slot. Mismatched firmware or configuration files between redundant controllers can cause voting discrepancies and spurious trips.
Additionally, inspect signal isolators and surge protection devices on thermocouple, RTD, and 4–20 mA signal loops connected to the turbine control system. Components such as DIN-rail signal isolators and loop-powered barriers protect the IS200VTURH2BAC from field-side transients; these should be tested and replaced on a scheduled basis as part of the annual maintenance plan.
Finally, review the HMI workstation and historian connectivity. The Mark VI system typically interfaces with a GE Cimplicity or iFIX SCADA platform; after a board replacement, verify that all process variables are correctly mapped and that alarm setpoints are intact in the HMI configuration.
Site Replacement Workflow
Step 1 — Pre-Replacement Verification: Confirm the exact part number and revision level of the installed IS200VTURH2BAC. Cross-reference with the Mark VI system bill of materials and the plant’s spare parts register. Verify that the replacement unit from NINERMAS matches the required hardware revision.
Step 2 — Safe Isolation: Follow the plant’s lockout/tagout (LOTO) procedure for the affected Mark VI controller. In redundant (TMR) systems, confirm that the remaining two controllers are healthy and in control before isolating the faulted board. Do not remove the board under live bus conditions unless the system architecture explicitly supports hot-swap for this slot.
Step 3 — Physical Replacement: Remove the faulty IS200VTURH2BAC by releasing the board retaining latches and carefully extracting it from the backplane. Inspect the backplane connector for damage. Insert the replacement board firmly and evenly, ensuring full connector engagement. Secure the retaining latches.
Step 4 — Configuration Restore: Download the correct Mark VI application configuration to the replacement board using the GE Toolbox software. Verify that I/O assignments, protection setpoints, and communication parameters match the plant baseline configuration file. Do not rely on default factory settings.
Step 5 — Functional Test: With the turbine in a safe state, perform a loop check on all I/O channels associated with the IS200VTURH2BAC. Verify analog input scaling, digital output response, and protection relay actuation. Confirm that the Mark VI diagnostic display shows no active faults on the replaced board.
Step 6 — Return to Service: Re-enable the controller in the TMR voting scheme, confirm synchronization with the remaining controllers, and monitor system diagnostics for a minimum of 30 minutes before returning the turbine to normal operation. Document the replacement in the plant maintenance management system (CMMS).
Spare Parts Support FAQ
Q1: Is the IS200VTURH2BAC still available as a new original part, or only as refurbished stock?
GE has progressively reduced support for Mark VI hardware as the platform approaches end-of-life. NINERMAS maintains a mixed inventory of original surplus and refurbished-tested units. All units — regardless of condition classification — undergo pre-shipment functional testing and are dispatched with a 12-month warranty. Condition is confirmed at the time of order inquiry.
Q2: How do I verify hardware revision compatibility before ordering?
Provide NINERMAS with the full part number including revision suffix (e.g., IS200VTURH2BAC vs. IS200VTURH2BAA) and the Mark VI system serial number or application software version. Our technical team will cross-reference the revision matrix and confirm compatibility before dispatch. Do not install a mismatched revision without engineering review.
Q3: What is the lead time for emergency orders, and do you support long-term supply agreements?
For in-stock units, NINERMAS targets same-day or next-business-day dispatch for emergency orders. For planned maintenance programs, we offer long-term supply agreements with committed stock reservation, fixed pricing, and priority dispatch — designed to support annual shutdown schedules and multi-year spare parts strategies for aging Mark VI installations.
Q4: What documentation is provided with each IS200VTURH2BAC shipment?
Each unit is shipped with a test report confirming pre-shipment functional verification, a warranty certificate valid for 12 months from the shipment date, and a packing list. Upon request, NINERMAS can provide a certificate of conformance and traceability documentation for quality management system (QMS) compliance.
| Product Series | Mark VI |
|---|---|
| Country of Origin | US |
Catalog Continuation
Nearby part numbers around IS200VTU.
Use this lane when the buyer is comparing adjacent model numbers, revision-near items, or closely related spare variants within the same brand family.
Catalog Continuation
More GE modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: DS200TCPSG1APE
GE DS200TCPSG1APE Power Supply | Industrial Safety & Performance
SKU: IC600LX624 IC600FP608K IC600LX624L
GE IC600LX624 Safety-Reliable Memory Module for Critical Control
SKU: IS220PDIOH1A REV.E
GE IS220PDIOH1A REV.E | Mark VIe Retrofit & System Upgrade I/O Pack
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.