Original Industrial Spare Part
ASML 4022-436-1723-112052-8 Retrofit Heater for Legacy Systems
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU4022.436.1723 112052-8 HEATER TI-XZ 0200-36543 BLM-013468
- CategoryPLC & Industrial Automation Modules
- BrandASML
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: ASML 4022-436-1723-112052-8 Retrofit Heater for Legacy Systems with SKU 4022.436.1723 112052-8 HEATER TI-XZ 0200-36543 BLM-013468.
ASML 4022-436-1723-112052-8 Retrofit Heater for Legacy Systems: Seamless Compatibility and Smooth Upgrade
The ASML 4022-436-1723-112052-8 is a precision heater assembly — also referenced under cross-part numbers 112052-8, BLM-013468, and TI-XZ 0200-36543 — designed for thermal control within ASML PAS 5500 and XT-series lithography platforms. As ASML progressively phases out legacy platform support, procurement teams and process engineers face increasing pressure to source verified replacement units that maintain original thermal performance specifications without requiring full platform requalification. This unit is stocked, pre-shipment tested, and backed by a 12-month warranty, making it a reliable retrofit solution for facilities operating legacy exposure tools.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| Primary SKU | 4022-436-1723-112052-8 |
| Cross-Reference Numbers | 112052-8, BLM-013468, TI-XZ 0200-36543 |
| Brand / OEM | ASML |
| Compatible Platforms | ASML PAS 5500 Series, XT Series Lithography Systems |
| Function | Thermal Heater Control Assembly (Laser Assy) |
| Mounting Interface | OEM-standard backplane connector; no mechanical modification required |
| Power Requirements | Verify against host system power budget prior to installation |
| Communication Compatibility | Compatible with existing ASML internal bus architecture |
| Replacement Recommendation | Direct drop-in for legacy units; confirm terminal wiring map before swap |
| Commissioning Notes | Calibrate thermal setpoints post-installation; verify HMI feedback loop |
| Warranty | 12-Month Warranty, Pre-Shipment Tested |
| Inventory Status | In Stock — Long-Term Supply Available |
Retrofit Planning for Existing Automation Systems
Replacing the ASML 4022-436-1723-112052-8 in a live production environment requires careful pre-work to avoid unplanned downtime and configuration drift. Engineers should begin by auditing the existing thermal control loop: confirm the heater’s rated wattage against the system’s available power capacity, and cross-check the terminal wiring diagram against the replacement unit’s pinout. In most PAS 5500 installations, the heater assembly interfaces directly with the thermal management backplane, so verifying backplane slot compatibility and connector seating torque is essential before powering up.
During the retrofit, teams commonly encounter the need to simultaneously address adjacent components. The ASML 4022-436-1724 series power distribution modules often require inspection when heater assemblies are replaced, as thermal cycling stress can degrade connector integrity on nearby boards. Similarly, the 4022-436-1725 communication interface boards should be checked for firmware version alignment, particularly if the replacement heater assembly carries a revised hardware revision. In systems where the ASML PAS 5500 I/O expansion chassis is involved, confirming module address assignments before and after the swap prevents address conflicts that can cause the system controller to flag false fault conditions.
For facilities running ASML XT-series tools, the retrofit path may also involve reviewing the ASML 4022-436-1700 series control backplane for slot availability and verifying that the ASML 4022-436-1710 signal conditioning modules are not impacted by the thermal zone reconfiguration. HMI screen updates — particularly on ASML’s internal operator interface — should be validated post-swap to confirm that temperature readback channels are correctly mapped to the new unit’s sensor outputs. If the facility uses a third-party SCADA overlay or process monitoring system, the thermal channel tag assignments may need to be updated in the historian configuration.
Communication link integrity is another critical checkpoint. In systems where the heater assembly communicates status back to the main process controller via the ASML internal fieldbus, engineers should verify that the replacement unit’s node address is correctly set and that the fieldbus scan cycle recognizes the new device without requiring a full system restart. Where ASML 4022-436-1730 series fieldbus interface modules are present, a brief bus diagnostic scan is recommended before returning the tool to production. Signal isolation between the heater control circuit and adjacent I/O — particularly where ASML 4022-436-1740 series signal isolators are installed — should also be confirmed to prevent ground loop interference after the swap.
Physical installation space is frequently underestimated in retrofit planning. The 4022-436-1723-112052-8 occupies a defined envelope within the control cabinet; confirm that cable management does not obstruct airflow to adjacent thermal modules. Where ASML 4022-436-1750 series cooling assemblies are co-located, ensure that the replacement heater’s exhaust path does not recirculate heat into the cooling zone. All units supplied by NINERMAS are pre-shipment tested under load conditions to verify thermal output, connector integrity, and communication response before dispatch.
Downtime Control During System Migration
Minimizing unplanned downtime during a heater assembly replacement on an ASML lithography tool requires a structured migration sequence. Begin with a full backup of the process recipe database and thermal calibration parameters stored in the system controller — this protects original program logic and allows rapid restoration if the replacement unit requires re-tuning. Schedule the physical swap during a planned maintenance window, ideally aligned with a reticle change or scheduled PM cycle, to avoid interrupting active exposure lots.
During the swap, maintain field control continuity by keeping adjacent process zones active where the system architecture permits partial isolation. In PAS 5500 configurations, the thermal control zone for the heater assembly can often be isolated without shutting down the entire wafer stage, reducing the scope of the maintenance window. After installation, perform a controlled power-up sequence: energize the heater assembly first in a low-power diagnostic mode, confirm sensor feedback on the HMI, then ramp to operating setpoint under process engineer supervision.
Document the as-found and as-left condition of all terminal connections, module addresses, and calibration values. This record supports future audits and accelerates the next replacement cycle. NINERMAS maintains reserved inventory for the ASML 4022-436-1723-112052-8 and related assemblies, enabling rapid dispatch to minimize lead time risk for facilities with critical uptime requirements.
Retrofit Support FAQ
Q1: Is the ASML 4022-436-1723-112052-8 a direct replacement for the original OEM unit?
Yes. This unit is a verified retrofit-compatible replacement for the original ASML heater assembly. It matches the OEM mechanical envelope, connector pinout, and thermal output specification. Confirm the cross-reference numbers (112052-8, BLM-013468, TI-XZ 0200-36543) against your system’s BOM before ordering.
Q2: What commissioning steps are required after installation?
After physical installation and terminal connection verification, power up in diagnostic mode and confirm thermal sensor feedback on the HMI. Calibrate the thermal setpoint to match the process recipe requirement. Verify fieldbus node recognition and confirm no fault flags are present on the system controller before returning the tool to production.
Q3: Is pre-shipment testing included, and what does it cover?
Yes. All units are tested prior to shipment under load conditions. Testing covers thermal output verification, connector integrity, communication response, and basic functional validation. A 12-month warranty is included from the date of shipment.
Q4: What is the inventory availability and lead time?
The ASML 4022-436-1723-112052-8 is maintained in reserved stock to support urgent replacement requirements. Standard dispatch is available for in-stock units. For facilities with recurring demand, NINERMAS offers long-term supply commitments and reserved inventory programs to eliminate lead time risk and support spare parts lifecycle planning.
| Product Series | Legacy |
|---|
Catalog Continuation
More ASML modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: OCTU/UC 4022.192.9463
ASML OCTU-UC-4022-192-9463 Safety-Reliable PCB for Critical Sites
SKU: 4022.471.73662 0195-12261 UHG50-2B A4249-9215HG
ASML 4022.471.73662 Service-Ready Spare Part for Industrial Maintenance
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 4-AXIS BXI4/2-01-B
BERKELEY BXI4/2-01-B Retrofit-Compatible Motion Controller
SKU: METEOR/RGB PCI 571-03
Matrox METEOR/RGB PCI 571-03 Service-Ready Spare Part