Original Industrial Spare Part
Allen-Bradley 1756HP-GPS GPS Time Sync Module | Original & New Spare Parts
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU1756HP-GPS
- CategoryPLC & Industrial Automation Modules
- BrandAllen-Bradley (Rockwell)
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Allen-Bradley 1756HP-GPS GPS Time Sync Module | Original & New Spare Parts with SKU 1756HP-GPS.
Allen-Bradley 1756HP-GPS GPS Time Synchronization Module – Industrial Process Solution
Technical Overview & First Impression
As a Global Sourcing Manager with over a decade of experience in industrial automation procurement, I can state with confidence that the Allen-Bradley 1756HP-GPS represents one of the most critical Legacy Components in any ControlLogix-based Distributed Control System. This GPS time synchronization module is engineered to deliver satellite-referenced precision timing — accurate to ±1 microsecond — directly into the ControlLogix backplane, enabling coordinated Process Control across geographically dispersed facilities, SCADA networks, and Fieldbus architectures.
What sets the Allen-Bradley 1756HP-GPS apart from generic timing solutions is its seamless integration with the 1756 chassis ecosystem. Unlike third-party alternatives that require complex middleware or protocol conversion, this module communicates natively via the ControlLogix backplane. Its compatibility spans firmware revision 16 and above, making it a reliable choice for both modern deployments and Legacy Upgrade projects where DCS Hardware continuity is non-negotiable. Factory Sealed Condition units are increasingly scarce — a reality that procurement teams in petrochemical, power, and mining sectors know all too well.
Original stock of this module is finite. As Allen-Bradley continues to evolve its product portfolio, sourcing a Factory Sealed, 100% authentic 1756HP-GPS from a verified distributor becomes the single most important step in protecting your plant’s operational continuity. This is not merely a component — it is a cornerstone of your system’s time-critical infrastructure.
Key Technical Highlights
GPS Precision Timing: ±1 microsecond accuracy to UTC via 12-channel parallel satellite tracking — the gold standard for Stability in distributed automation environments.
Native Backplane Integration: Communicates directly with all ControlLogix processors and I/O modules in the same chassis without additional configuration overhead.
Holdover Oscillator (TCXO): Internal temperature-compensated crystal oscillator maintains ±10 µs/hour accuracy during GPS signal interruptions — ensuring Redundancy when satellite visibility is compromised.
High-Speed Synchronization: Broadcasts time data automatically across the backplane at High-speed intervals, eliminating polling latency in time-sensitive Process Control loops.
TNC Antenna Interface: Industry-standard connector supports a wide range of external GPS antennas for flexible installation in complex plant environments.
Low Power Draw: 800mA @ 5V DC, 5mA @ 24V DC — minimal chassis power budget impact even in fully loaded 1756 racks.
Status Diagnostics: Dedicated LEDs for GPS lock, module health, and backplane activity enable rapid fault isolation without software tools.
Vertical Industry Applications
Petrochemical & Refining: In high-hazard process environments, synchronized timestamps are mandatory for sequence-of-events (SOE) recording, safety instrumented system (SIS) coordination, and regulatory audit trails. The 1756HP-GPS eliminates timing drift between distributed control nodes, reducing the risk of cascading failures and minimizing unplanned downtime during critical process transitions.
Power Generation & Transmission: Substation automation and protective relay coordination demand sub-millisecond time alignment. This module provides the GPS-referenced time base required for IEEE 1588 PTP-compatible systems, enabling precise fault location and accelerated grid restoration after disturbances.
Mining & Mineral Processing: Remote mine sites with distributed SCADA architectures rely on GPS timing to correlate data from multiple PLCs and RTUs across vast geographic areas. The 1756HP-GPS ensures that production data, alarm logs, and safety events are accurately time-stamped regardless of network latency.
Marine & Offshore Platforms: Vessel automation and offshore platform control systems require robust, satellite-based timing that is immune to terrestrial network disruptions. The module’s holdover capability is particularly valuable in environments where GPS antenna positioning is challenging.
Water & Wastewater Infrastructure: Municipal utilities managing distributed lift stations and treatment facilities use GPS synchronization to coordinate SCADA alarms, regulatory sampling events, and energy optimization routines — all of which depend on a single, authoritative time source.
Data Sheet & Specifications
| Property | Detailed Value |
|---|---|
| Complete Model Number | 1756HP-GPS |
| Manufacturer / Brand | Allen-Bradley (Rockwell Automation) |
| Product Series | ControlLogix 1756 |
| Product Category | GPS Time Synchronization Module / DCS Hardware |
| Time Accuracy | ±1 microsecond to UTC (GPS-locked) |
| Holdover Accuracy | ±10 microseconds per hour (TCXO) |
| GPS Receiver Channels | 12-channel parallel tracking |
| Antenna Connector | TNC (external GPS antenna required) |
| Backplane Current (5V DC) | 800 mA |
| Backplane Current (24V DC) | 5 mA |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Mounting | Standard ControlLogix 1756 chassis slot |
| Firmware Compatibility | ControlLogix firmware revision 16 and later |
| Communication Protocol | ControlLogix backplane (native integration) |
| Status Indicators | GPS Lock LED, Module OK LED, Backplane Activity LED |
| Country of Origin | United States |
| Condition Available | Factory Sealed / New Surplus / Tested Refurbished |
| Warranty | 12-Month Comprehensive Warranty |
Quality Assurance & Supply Chain
Every unit of the Allen-Bradley 1756HP-GPS supplied through our network undergoes a rigorous multi-stage verification process before shipment. We source exclusively from authorized distribution channels and verified OEM surplus inventories, ensuring that each module is 100% Original and free from counterfeit risk — a critical concern in the DCS Hardware aftermarket.
Our 12-Month Comprehensive Warranty covers all manufacturing defects, component failures, and functional anomalies. Should a unit fail within the warranty period, we provide immediate replacement or full refund — no bureaucratic delays. For Emergency Repair scenarios, we maintain dedicated fast-track inventory with same-day dispatch capability via DHL Express, FedEx International Priority, and UPS Worldwide Expedited, reaching most global destinations within 24-72 hours.
Each shipment includes: original manufacturer packaging (where available), anti-static protective packaging, detailed inspection report, and full traceability documentation. For clients requiring Maintenance Stock programs, we offer scheduled delivery agreements and reserved inventory allocation to eliminate procurement risk for this Critical Part for Industry Safety.
Buyer’s FAQ — Selection Guide
Q1: How can I verify that the 1756HP-GPS I receive is 100% original and not a counterfeit?
Authentic Allen-Bradley 1756HP-GPS modules carry a holographic Rockwell Automation certification label on the module housing, a unique serial number traceable through Rockwell’s product verification portal, and factory-sealed anti-tamper packaging. We provide full traceability documentation with every shipment. If you have concerns, our team can arrange third-party inspection before dispatch.
Q2: How do I obtain the official datasheet and installation manual for the 1756HP-GPS?
The official product documentation — including the installation instructions, user manual, and technical specifications — is published by Rockwell Automation and available through their official literature library. Our technical team can also provide application notes and configuration guides specific to your ControlLogix firmware version upon request.
Q3: Is the 1756HP-GPS compatible with all ControlLogix chassis and controller firmware versions?
The module is compatible with all standard 1756 ControlLogix chassis (4-slot through 17-slot) and requires controller firmware revision 16 or later. It is not compatible with CompactLogix or SoftLogix platforms. For Legacy Upgrade projects involving older firmware, our engineers can advise on the minimum firmware update path required before installation.
Q4: What is the lead time for emergency orders, and which shipping carriers do you use?
For in-stock units, same-day dispatch is available for orders confirmed before 14:00 local time. We ship via DHL Express, FedEx International Priority, and UPS Worldwide Expedited. Typical transit times range from 24 hours (Asia-Pacific) to 72 hours (Americas and Europe). Emergency freight documentation and customs pre-clearance support are included at no additional charge.
Q5: Can the 1756HP-GPS be used as a drop-in replacement for a failed timing module in a live production environment?
Yes. The module is hot-swappable within a powered ControlLogix chassis, provided the chassis supports this feature (1756-A7, 1756-A10, 1756-A13, 1756-A17 series). No controller shutdown is required. Upon insertion, the module automatically acquires GPS lock and begins broadcasting synchronized time to the backplane within minutes. Our technical team can provide step-by-step replacement guidance for your specific system configuration.
Q6: Why is the 1756HP-GPS considered a Critical Part for Industry Safety?
In process industries governed by IEC 61511 (SIS) and IEC 61508 (Functional Safety) standards, accurate event timestamping is a mandatory requirement for safety audit trails and incident investigation. A failed or drifting time source can invalidate SOE records, compromise SIS response time verification, and create regulatory compliance gaps. The 1756HP-GPS is the only Allen-Bradley-native solution that provides GPS-referenced time directly to the ControlLogix backplane — making it irreplaceable in safety-critical Distributed Control System architectures.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667
| Product Series | ControlLogix 1756 |
|---|---|
| Country of Origin | US |
Catalog Continuation
More Allen-Bradley (Rockwell) modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
Reviews
There are no reviews yet.