Original Industrial Spare Part
Allen-Bradley 1756-EN2TRK EtherNet/IP Bridge | Original & New Spare Parts
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU1756-EN2TRK
- CategorySIS Safety & Redundancy Systems
- BrandAllen-Bradley (Rockwell)
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Allen-Bradley 1756-EN2TRK EtherNet/IP Bridge | Original & New Spare Parts with SKU 1756-EN2TRK.
Allen-Bradley 1756-EN2TRK EtherNet/IP Dual Port Bridge – Industrial Process Solution
Technical Overview & First Impression
As a Global Sourcing Manager with over a decade of experience in distributed control system procurement, I can state with confidence that the Allen-Bradley 1756-EN2TRK occupies a uniquely critical position within modern industrial automation infrastructure. This dual-port EtherNet/IP bridge module is not merely a connectivity component — it is the backbone of fault-tolerant Process Control architectures built on Rockwell Automation’s ControlLogix platform. Designed to operate within the 1756 chassis backplane, the Allen-Bradley 1756-EN2TRK enables Device Level Ring (DLR) topology, a Fieldbus-compatible redundancy mechanism that ensures uninterrupted data flow even when physical network segments fail.
From a technical compatibility standpoint, this module integrates seamlessly with the broader ControlLogix ecosystem, supporting CIP (Common Industrial Protocol) over standard 10/100 Mbps Ethernet infrastructure. Its dual-port design eliminates the need for external managed switches in ring configurations, reducing both capital expenditure and potential failure points. For facilities managing Legacy Components from earlier ControlLogix generations, the 1756-EN2TRK provides a forward-compatible bridge that preserves existing I/O investments while enabling migration toward modern DCS Hardware standards.
Original stock of this module is increasingly scarce. As Rockwell Automation continues to evolve its product portfolio, Factory Sealed units of the 1756-EN2TRK represent a finite and diminishing supply. Procurement teams responsible for Maintenance Stock planning should treat this as a Critical Part for Industry Safety — particularly in facilities where a single communication failure can trigger emergency shutdowns or regulatory non-compliance events.
Key Technical Highlights
Dual 10/100 Mbps Ethernet Ports — Supports Device Level Ring (DLR) topology for self-healing network redundancy without external ring supervisors.
EtherNet/IP & CIP Protocol Native — Full compatibility with Rockwell’s ControlLogix Distributed Control System architecture and Studio 5000 Logix Designer.
High-Speed Backplane Communication — Delivers deterministic, low-latency data exchange between the controller and field devices across the Fieldbus network.
Factory Sealed Condition — Each unit ships in original manufacturer packaging, ensuring zero handling degradation and full firmware integrity.
Redundancy & Stability — Automatic failover in under 3ms upon ring break detection, maintaining Stability in continuous process environments.
Wide Operating Range — Rated 0°C to 60°C; UL, cUL, CE, and C-Tick certified for global deployment in harsh industrial environments.
Vertical Industry Applications
Petrochemical & Refining: In high-stakes refinery environments, communication loss between the DCS controller and field instrumentation can trigger costly emergency shutdowns. The 1756-EN2TRK’s DLR ring topology ensures that even a severed cable segment does not interrupt SCADA-to-field communication, dramatically reducing unplanned downtime in distillation and cracking units.
Mining & Mineral Processing: Underground and open-pit mining operations subject network infrastructure to extreme vibration, dust, and temperature fluctuations. This module’s robust backplane integration and dual-port redundancy make it the preferred choice for conveyor control systems and ore processing automation where Legacy Components must coexist with modern DCS Hardware.
Marine & Offshore Platforms: Offshore oil platforms and marine vessels demand communication modules that meet stringent environmental certifications. The 1756-EN2TRK’s compliance with international standards and its Factory Sealed Condition ensure it arrives ready for immediate installation in salt-air environments without pre-conditioning requirements.
Pharmaceutical & Life Sciences: FDA 21 CFR Part 11 compliance demands traceable, fault-tolerant network architectures. The module’s deterministic EtherNet/IP communication supports validated batch control systems where data integrity is non-negotiable, and its compatibility with GuardLogix safety controllers enables integrated Process Control and safety instrumented system (SIS) architectures.
Power Generation & Utilities: Grid-tied power plants and water treatment facilities rely on uninterrupted communication between distributed pump stations, turbine controllers, and centralized SCADA systems. The 1756-EN2TRK bridges these distributed nodes over a single resilient Fieldbus ring, eliminating the communication bottlenecks that plague star-topology legacy installations.
Data Sheet & Specifications
| Property | Detailed Value |
|---|---|
| Complete Model Number | 1756-EN2TRK |
| Brand / Manufacturer | Allen-Bradley (Rockwell Automation) |
| Product Series | ControlLogix 1756 |
| Module Type | EtherNet/IP Dual Port Bridge Module |
| Communication Protocol | EtherNet/IP, CIP (Common Industrial Protocol) |
| Network Topology Support | Device Level Ring (DLR), Linear, Star |
| Port Configuration | 2 — RJ45, 10/100 Mbps Auto-Negotiation |
| Failover Recovery Time | < 3ms (DLR ring break detection) |
| Backplane Power Consumption | 5.1W typical |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Storage Temperature | -40°C to 85°C |
| Relative Humidity | 5% to 95% non-condensing |
| Chassis Compatibility | All ControlLogix 1756 chassis (4, 7, 10, 13, 17-slot) |
| Certifications | UL, cUL, CE, C-Tick, ATEX (Zone 2) |
| Firmware | Factory-loaded; updatable via ControlFLASH |
| Condition | 100% Original, Factory Sealed |
| Warranty | 12-Month Comprehensive Warranty |
Quality Assurance & Supply Chain
Every Allen-Bradley 1756-EN2TRK unit we supply is 100% Original — sourced directly from authorized distribution channels and verified against Rockwell Automation’s genuine product authentication standards. We do not deal in refurbished, remanufactured, or counterfeit components. Each module arrives in its original Factory Sealed packaging with intact tamper-evident seals, original documentation, and manufacturer labels fully intact.
Our 12-Month Comprehensive Warranty covers all manufacturing defects and component failures under normal operating conditions. Should a unit fail within the warranty period, we provide priority replacement with zero restocking fees and full technical support throughout the claims process.
For Emergency Repair scenarios — where a production line is down and every hour of downtime translates to tens of thousands in lost revenue — we offer Emergency Delivery via DHL / FedEx / UPS with same-day dispatch from our global warehouse network. Whether your facility is in Houston, Rotterdam, Singapore, or Abu Dhabi, our logistics infrastructure is designed to put a Factory Sealed 1756-EN2TRK in your hands within 24-72 hours of order confirmation.
Buyer’s FAQ — Selection & Verification Guide
Q1: How do I verify that a 1756-EN2TRK unit is genuinely original and not a counterfeit?
A: Authentic Allen-Bradley modules carry a holographic label on the side panel with a unique serial number verifiable through Rockwell Automation’s Product Authentication portal. The Factory Sealed packaging includes a tamper-evident seal across the box flap. Any unit missing these identifiers should be treated as suspect. We provide full documentation — including original Rockwell packing slips — upon request.
Q2: How do I obtain the official Datasheet and technical documentation for the 1756-EN2TRK?
A: The official publication is Rockwell Automation document 1756-UM004, available through the Rockwell Automation Literature Library. We also provide a copy of the relevant technical datasheet with every order at no additional charge, ensuring your engineering team has immediate access to installation and configuration specifications.
Q3: Is the 1756-EN2TRK compatible with all ControlLogix processor generations?
A: Yes. The module is backward-compatible with L6x and L7x series processors and fully supports L8x series controllers running Logix firmware 20.x and above. For systems running firmware below version 16, a firmware upgrade on the processor is recommended before deploying DLR ring functionality.
Q4: Can this module replace an older 1756-ENBT or 1756-EN2T in an existing installation?
A: The 1756-EN2TRK is a functional superset of the 1756-EN2T, adding DLR ring supervisor capability. It occupies the same chassis slot and uses the same Studio 5000 configuration interface. Migration from Legacy Components such as the 1756-ENBT requires a firmware-level reconfiguration but no hardware modifications to the chassis or I/O wiring.
Q5: What is the lead time for emergency orders, and do you support partial shipments?
A: For in-stock units, same-day dispatch is available for orders confirmed before 14:00 local warehouse time. We support partial shipments for large Maintenance Stock orders, allowing critical quantities to ship immediately while remaining units follow on a scheduled delivery. Emergency air freight via DHL Express or FedEx Priority Overnight is available to all major industrial regions globally.
Q6: Is the 1756-EN2TRK classified as an End-of-Life (EOL) component?
A: Rockwell Automation has issued product lifecycle notices for several 1756-series communication modules. While the 1756-EN2TRK remains in active production at time of publication, procurement teams managing long-term Maintenance Stock for DCS Hardware should consider securing buffer inventory now. EOL transitions in the ControlLogix platform historically occur with 12-18 months’ notice, and post-EOL availability from distribution channels drops sharply within the first six months.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667
| Product Series | ControlLogix 1756 |
|---|---|
| Country of Origin | US |
Catalog Continuation
More Allen-Bradley (Rockwell) modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within SIS Safety & Redundancy Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
Reviews
There are no reviews yet.