Original Industrial Spare Part
Allen-Bradley 1756-BA2 | ControlLogix L6X Series B Certified Battery
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU1756-BA2
- CategoryPLC & Industrial Automation Modules
- BrandAllen-Bradley (Rockwell)
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Allen-Bradley 1756-BA2 | ControlLogix L6X Series B Certified Battery with SKU 1756-BA2.
Allen-Bradley 1756-BA2 — Lifecycle Excellence & Technical Performance
Operational Integrity & System Analysis
From the perspective of an Industrial Compliance Consultant, the Allen-Bradley 1756-BA2 represents a foundational element in maintaining the operational integrity of ControlLogix L6X Series B control architectures. As a certified OEM lithium battery assembly, the 1756-BA2 fulfills a non-negotiable role in safeguarding volatile memory retention across mission-critical automation nodes nsuring that program logic, data files, and configuration parameters remain intact during unplanned power interruptions or scheduled maintenance windows. Its deployment is not merely a component decision; it is a compliance-driven asset optimization strategy that directly impacts system uptime and regulatory adherence.
Within the framework of Industry 4.0 and IIoT-integrated manufacturing environments, the 1756-BA2 demonstrates sustained long-term compatibility with Rockwell Automation’s ControlLogix ecosystem. Its electrochemical stability under variable thermal and load conditions ensures that lifecycle performance metrics remain within OEM-specified tolerances over multi-year operational cycles. Asset managers integrating this component into their preventive maintenance schedules benefit from predictable replacement intervals, reduced unplanned downtime, and full traceability through Original Documentation supplied by the manufacturer.
As a certified original component, the 1756-BA2 carries the full weight of Allen-Bradley’s quality control infrastructure ncluding UL Listing, CE Marking, and RoHS compliance aking it the only defensible choice for facilities operating under ISO 9001, IEC 62443, or OSHA-regulated environments where system safety integrity cannot be compromised by counterfeit or non-OEM substitutes.
Compliance & Safety Benchmarks
✅ UL Listed & CE Marked: Meets international electrical safety standards for industrial deployment in North American and European regulated facilities.
✅ RoHS Compliant: Manufactured without restricted hazardous substances, ensuring environmental compliance across global supply chains.
Series B Exclusivity: Engineered exclusively for ControlLogix L6X Series B controllers. Use of non-designated battery assemblies constitutes a compliance violation and voids OEM warranty coverage.
✅ Standard Adherence: Fully aligned with IEC 60086 primary lithium battery standards and Rockwell Automation’s internal qualification protocols.
✅ Durability Rating: Rated for 5-year service life under standard industrial operating conditions (0°C to 60°C), with a storage tolerance of -40°C to 85°C.
Counterfeit Risk Advisory: Only procure from authorized distributors. Non-genuine assemblies present latent failure risks that compromise Safety Integrity Levels (SIL) in process-critical applications.
Vertical Industry Integration & Optimization
Semiconductor Fabrication: In cleanroom automation environments where process continuity is paramount, the 1756-BA2 ensures that ControlLogix L6X Series B controllers retain wafer recipe parameters and equipment sequencing logic during facility power transitions liminating costly batch failures and requalification cycles.
Pharmaceutical Manufacturing: GMP-regulated production lines require uninterrupted data integrity for batch records and process validation. The 1756-BA2 supports 21 CFR Part 11 compliance by preserving controller memory states that underpin electronic audit trails and automated process controls.
Chemical Processing: In environments governed by HAZOP and LOPA safety methodologies, the 1756-BA2 contributes to the functional safety layer by ensuring that safety-instrumented system (SIS) logic controllers maintain their operational state during power anomalies, reducing the probability of dangerous failure modes.
Oil & Gas SCADA Systems: Remote terminal units and distributed control nodes in upstream and midstream operations depend on reliable memory backup to sustain SCADA integrity during grid instability. The 1756-BA2’s low self-discharge characteristics make it particularly suited for installations with extended maintenance intervals.
Automotive Assembly: High-throughput production environments with zero-tolerance for unplanned stoppages leverage the 1756-BA2 as a critical asset in their controller lifecycle management programs, ensuring that robotic sequencing and quality inspection logic remain protected across shift changes and planned shutdowns.
Comprehensive Engineering Specifications
| Technical Attribute | Standard Value |
|---|---|
| Catalog / Model Number | 1756-BA2 |
| Manufacturer | Allen-Bradley (Rockwell Automation) |
| Battery Chemistry | 3V Lithium (Primary Cell) |
| Nominal Voltage | 3.0V DC |
| Compatible Platform | ControlLogix L6X Series B Controllers ONLY |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
| Expected Service Life | ~5 Years (Normal Operating Conditions) |
| Shelf Life (Unused) | Up to 10 Years (Stored 25°C, Dry Environment) |
| Certifications | UL Listed, CE Marked, RoHS Compliant |
| Self-Discharge Rate | Low (Lithium Primary Chemistry) |
| Product Condition | Brand New, Factory Sealed |
| Country of Origin | United States |
Fulfillment Strategy & Technical Support
Factory Sealed Condition: Every 1756-BA2 unit is dispatched in its original, factory-sealed packaging reserving electrochemical integrity and providing verifiable authenticity for incoming inspection and quality assurance protocols.
Rapid Global Logistics: Our certified distribution infrastructure supports expedited international shipment to industrial facilities across Asia-Pacific, Europe, the Americas, and the Middle East. Priority fulfillment options are available for emergency maintenance scenarios requiring immediate component replacement.
12-Month Quality Guarantee for Legacy Systems: We extend a comprehensive 12-month quality guarantee covering manufacturing defects and performance deviations from OEM specifications. This warranty is specifically structured to support legacy ControlLogix L6X Series B installations where component sourcing reliability is a critical operational concern.
Technical Support: Our engineering support team provides pre-sales compatibility verification, installation guidance, and post-deployment troubleshooting to ensure that every 1756-BA2 deployment meets the compliance and performance standards required by your facility’s operational framework.
Expert Technical FAQ
Q1: Does the 1756-BA2 comply with IEC 62443 cybersecurity and functional safety standards for industrial control systems?
A: While the 1756-BA2 is a hardware component rather than a software or network element, its role in maintaining controller memory integrity directly supports the availability requirements outlined in IEC 62443-3-3. Ensuring continuous memory backup prevents unauthorized state changes caused by power-induced data corruption, contributing to the overall Security Level (SL) posture of the control system.
Q2: What firmware version compatibility considerations apply when replacing the 1756-BA2 in an active ControlLogix L6X Series B system?
A: The 1756-BA2 is a passive hardware component with no firmware dependency. However, it is strongly recommended to verify that the host controller’s firmware is current prior to battery replacement, as outdated firmware may affect battery status reporting accuracy within RSLogix 5000 / Studio 5000 diagnostics.
Q3: How does the 1756-BA2 perform in high-ambient-temperature environments exceeding 50°C?
A: Operating the 1756-BA2 at the upper boundary of its rated temperature range (60°C) will accelerate electrochemical degradation and reduce effective service life below the nominal 5-year specification. Asset Optimization best practice recommends proactive replacement at 3-year intervals in environments consistently operating above 45°C.
Q4: Is the 1756-BA2 certified for use in ATEX or NEC Class I Division 2 hazardous locations?
A: The 1756-BA2 itself does not carry standalone ATEX or NEC Class I Div 2 certification. Its use in hazardous locations is governed by the enclosure and system-level certifications of the ControlLogix chassis and associated hardware. Consult your facility’s safety engineer and the applicable Rockwell Automation installation documentation before deploying in classified areas.
Q5: What Original Documentation is available to support incoming inspection and compliance audits?
A: Each genuine 1756-BA2 unit is accompanied by Rockwell Automation’s original product documentation, including the catalog specification sheet, compliance declarations (CE, RoHS), and UL Listing evidence. These documents support ISO 9001 incoming inspection procedures and can be provided upon request for regulatory audit purposes.
Q6: Can the 1756-BA2 be replaced while the ControlLogix controller remains energized (hot-swap)?
A: Rockwell Automation’s installation guidelines permit battery replacement while the controller is powered, as the live power supply maintains memory integrity during the swap. However, facility-specific safety procedures and lockout/tagout (LOTO) protocols must be evaluated by a qualified engineer before performing any maintenance on energized equipment.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667
| Product Series | ControlLogix 1756 |
|---|---|
| Country of Origin | US |
Catalog Continuation
Likely ControlLogix 1756 platform matches.
These parts are closer to the same platform family signaled by the current SKU and title, so buyers can validate continuity before sending a final RFQ.
Catalog Continuation
More Allen-Bradley (Rockwell) modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: DIO32-C 00010129-00
DIO32-C Bachmann Digital I/O Module | 32-Channel 24VDC CANopen Controller
SKU: DI016-C❄ 00017453-00
DI016-C❄ Bachmann Cold Climate Digital Input Module | 16-Ch 24VDC CANopen
SKU: 6SL3130-1TE31-0AA0
Reviews
There are no reviews yet.