Original Industrial Spare Part
Allen-Bradley 1719-AENTR EtherNet/IP Adapter (Allen-Bradley) – New & Original in Stock
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU1719-AENTR
- CategoryPLC & Industrial Automation Modules
- BrandAllen-Bradley (Rockwell)
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Allen-Bradley 1719-AENTR EtherNet/IP Adapter (Allen-Bradley) - New & Original in Stock with SKU 1719-AENTR.
Allen-Bradley 1719-AENTR | Reliable Automation Component for Mission-Critical Networks
Field Application & Operational Analysis
From a Site Reliability Engineer’s perspective, the Allen-Bradley 1719-AENTR is a cornerstone component for sustaining system availability in distributed I/O architectures. By bridging legacy 1719 Remote I/O backplanes to modern EtherNet/IP control networks, the 1719-AENTR eliminates costly full-system replacements while delivering the real-time data throughput that mission-critical automation demands. Its role in process optimization cannot be overstated — downtime events traced to communication failures are dramatically reduced when this adapter is correctly deployed.
Engineered for operational excellence in harsh industrial environments, the 1719-AENTR withstands wide thermal cycling, electrical noise, and vibration conditions common in heavy manufacturing and process facilities. During installation, engineers should verify DIN rail seating integrity, confirm 24VDC supply stability within the 19.2-30VDC tolerance band, and validate EDS file registration in RSNetWorx prior to commissioning. Conformal coating variants are available for high-humidity or chemically aggressive enclosures.
As a strategic spare-parts asset, maintaining at least one 1719-AENTR in your critical inventory buffer is a recognized best practice for SRE teams managing legacy-to-modern migration projects. End-of-life (EOL) procurement windows for this module are narrowing — securing original factory stock now ensures uninterrupted system integration continuity for years ahead.
Key Operational Features
Dual-Port EtherNet/IP with Embedded Switch — Eliminates external switch hardware; supports linear and Device Level Ring (DLR) topologies for high availability.
Sub-50ms DLR Failover — Redundancy at the network layer ensures seamless integration continuity during cable or node faults.
32-Module I/O Capacity — Scales to support large distributed I/O networks without additional adapters.
Auto-Negotiating 10/100 Mbps — Compatible with mixed-speed Ethernet infrastructure; no manual speed configuration required.
CIP-Native Protocol Stack — Direct interoperability with ControlLogix, CompactLogix, and third-party EtherNet/IP controllers.
Change-of-State & Polled Transmission Modes — Optimizes bandwidth utilization across varied automation components and I/O modules.
Diagnostic LED Array — Real-time module status, network activity, and fault indication for rapid field troubleshooting.
Maintenance & Performance Benchmarks
The 1719-AENTR is architected to adapt across small-cell manufacturing cells and large-scale plant-wide Ethernet backbones alike. In compact automation environments, a single adapter can manage an entire remote I/O cluster, reducing wiring complexity and cabinet footprint. In enterprise-scale deployments, multiple 1719-AENTR units operate in parallel ring segments, each contributing to a resilient, self-healing network fabric that supports operational excellence targets of 99.9%+ uptime.
Firmware management is straightforward: the module supports in-field firmware updates via RSNetWorx for EtherNet/IP (v16+), ensuring compatibility with evolving controller firmware revisions without hardware replacement. Scheduled preventive maintenance should include periodic LED status audits, Ethernet port integrity checks, and EDS file version validation — all executable without production line interruption when DLR redundancy is active.
For system integration projects involving mixed-generation I/O modules, the 1719-AENTR’s backward compatibility with the full 1719 series — including analog, digital, and specialty function blocks — makes it the preferred adapter for phased modernization programs that prioritize process optimization without wholesale infrastructure overhaul.
Comprehensive Data Sheet
| Attribute | Technical Data |
|---|---|
| Part Number / SKU | 1719-AENTR |
| Brand | Allen-Bradley (Rockwell Automation) |
| Product Series | 1719 Remote I/O |
| Product Type | EtherNet/IP Communication Adapter |
| Communication Protocol | EtherNet/IP, CIP (Common Industrial Protocol) |
| Network Ports | Dual RJ45, 10/100 Mbps, embedded switch |
| Topology Support | Linear, Star, Device Level Ring (DLR) |
| DLR Failover Time | < 50ms |
| Max I/O Modules Supported | 32 per adapter |
| Supply Voltage | 24VDC nominal (19.2-30VDC range) |
| Current Consumption | 150mA typical |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Mounting | DIN rail, 1719 backplane compatible |
| Conformal Coating Option | Available |
| Configuration Software | RSNetWorx for EtherNet/IP v16+ |
| Controller Compatibility | ControlLogix, CompactLogix, EtherNet/IP-capable PLCs |
| Condition | New & Original, Factory Packaging |
| Warranty | 1 Year |
Professional Logistics & Sourcing Excellence
Every 1719-AENTR unit dispatched from our inventory is sourced directly from authorized distribution channels and ships in original factory packaging — sealed, labeled, and traceable to manufacturer lot records. This guarantees authenticity and eliminates counterfeit risk for mission-critical automation components.
Same-day dispatch is available for in-stock orders confirmed before the daily cut-off, supported by partnerships with DHL Express, FedEx International Priority, and UPS Worldwide Expedited. For engineering teams managing EOL or legacy module procurement, our global supply network actively sources discontinued 1719 series components, providing a reliable pipeline even when standard distribution channels are exhausted.
All shipments include commercial invoice documentation, country-of-origin certification, and packing lists compliant with international customs requirements — ensuring frictionless cross-border delivery to manufacturing facilities worldwide.
Engineering Support & FAQ
Q1: What are the step-by-step installation requirements for the 1719-AENTR?
A: Mount the module on a grounded DIN rail within the 1719 backplane slot. Connect dual Ethernet cables to your network infrastructure. Apply 24VDC power within the 19.2-30VDC range. Register the EDS file in RSNetWorx for EtherNet/IP, then configure the IP address via BOOTP/DHCP or static assignment. Verify LED status indicators show solid green before going online.
Q2: Which firmware versions are compatible with current ControlLogix controllers?
A: The 1719-AENTR is compatible with RSNetWorx for EtherNet/IP v16 and later. For ControlLogix L7x and L8x series controllers running Studio 5000 v21+, no additional firmware patches are required. Always cross-reference the Rockwell Automation Product Compatibility and Download Center (PCDC) for the latest firmware matrix before deployment.
Q3: Does the 1719-AENTR support Device Level Ring (DLR) for network redundancy?
A: Yes. The dual Ethernet ports natively support DLR topology, delivering sub-50ms automatic failover. This is the recommended configuration for high-availability production lines where network interruption is unacceptable.
Q4: How is the warranty claim process handled?
A: Our 1-year warranty covers manufacturing defects and component failures under normal operating conditions. To initiate a claim, contact sale@ninermas.com with your order reference, module serial number, and a description of the fault. Replacement or repair is processed within 5-7 business days upon receipt of the defective unit.
Q5: Can the 1719-AENTR integrate with third-party EtherNet/IP controllers outside the Rockwell ecosystem?
A: Yes. Because the module implements the open CIP standard, it is interoperable with any EtherNet/IP-compliant controller. Third-party system integration may require manual EDS file import and IP address configuration via the controller’s network configuration utility.
Q6: What is the lead time for out-of-stock or EOL procurement?
A: For standard in-stock units, same-day or next-business-day dispatch applies. For EOL or legacy sourcing requests, our global supply team typically confirms availability within 3-5 business days. Contact us directly for urgent mission-critical requirements.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667
| Product Series | Other Legacy / Discontinued Modules |
|---|---|
| Country of Origin | US |
Catalog Continuation
More Allen-Bradley (Rockwell) modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: DIO32-C 00010129-00
DIO32-C Bachmann Digital I/O Module | 32-Channel 24VDC CANopen Controller
SKU: DI016-C❄ 00017453-00
DI016-C❄ Bachmann Cold Climate Digital Input Module | 16-Ch 24VDC CANopen
SKU: 6SL3130-1TE31-0AA0
Reviews