Original Industrial Spare Part
HIMA ETA2210 16A H7201 Circuit Breaker (HIMA) – New & Original in Stock
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUETA2210 16A H7201
- CategorySIS Safety & Redundancy Systems
- BrandHIMA
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: HIMA ETA2210 16A H7201 Circuit Breaker (HIMA) - New & Original in Stock with SKU ETA2210 16A H7201.
HIMA ETA2210 16A H7201 Circuit Breaker | Reliable Automation Component
Field Application & Operational Analysis
From a Site Reliability Engineer’s perspective, the HIMA ETA2210 16A H7201 is a mission-critical automation component engineered to sustain maximum system availability in safety instrumented systems (SIS) and emergency shutdown (ESD) architectures. Its thermal-magnetic trip mechanism delivers sub-cycle fault isolation, preventing cascading failures across H7201 infeed fuse boards — a decisive advantage in process optimization environments where every millisecond of uptime translates directly to production output.
Deployed across oil & gas terminals, chemical processing units, and power generation facilities, the HIMA ETA2210 16A H7201 demonstrates exceptional durability under sustained thermal stress and high-humidity industrial conditions. Installation engineers should note that DIN rail seating must achieve full mechanical engagement prior to energization; partial seating is the leading cause of intermittent contact resistance in field deployments. Torque specifications for adjacent terminal blocks should comply with HIMA H7201 board documentation to maintain IEC 60947-2 conformance.
As a legacy-compatible, EOL-resilient component, this breaker is an indispensable addition to any critical spare parts inventory. Facilities operating HIMA H7201 power distribution boards should maintain a minimum buffer stock to eliminate single-point-of-failure exposure during unplanned maintenance windows — a cornerstone of operational excellence in high-availability plant environments.
Key Operational Features
Rated Current: 16A — optimized for H7201 infeed fuse board channel assignments
Trip Characteristic: Thermal-magnetic — dual-mechanism protection for overload and short-circuit events
Breaking Capacity: 10kA @ 240V AC — handles fault currents in high-density I/O module power rails
Redundancy-Ready: Hot-swap compatible design supports seamless integration into redundant power architectures
High Availability: Mechanical life >20,000 operations; factory-calibrated trip thresholds eliminate field drift
Standards Compliance: IEC 60947-2 / UL 489 certified — accepted by global regulatory and insurance frameworks
Visual Fault Indication: Integrated trip flag enables rapid fault localization without instrumentation
Operating Range: -25°C to +70°C — qualified for arctic-grade and tropical industrial environments
Maintenance & Performance Benchmarks
The ETA2210 16A H7201 is architected to integrate without modification into both small-scale distributed control nodes and large-scale plant-wide automation networks. In multi-cabinet HIMA H7201 deployments, each breaker channel provides isolated overcurrent protection, ensuring that a fault on one I/O module power rail does not propagate to adjacent system integration segments.
Preventive maintenance intervals for this component class are typically aligned with annual plant turnarounds. Field benchmarks indicate that thermal-magnetic breakers in continuous-duty SIS applications retain >98% of factory trip accuracy over a 5-year service cycle when ambient temperatures remain within rated limits. For facilities implementing IEC 61511 functional safety management, this breaker’s documented trip characteristics support proof-test documentation requirements without requiring specialized test equipment.
In high-density cabinet configurations, engineers should verify that aggregate load current across all H7201 channels does not exceed the infeed bus rating. Load balancing across breaker positions is a proven strategy for extending mean time between failures (MTBF) and reducing thermal derating in confined enclosure environments.
Comprehensive Data Sheet
| Attribute | Technical Data |
|---|---|
| Full Part Number | ETA2210 16A H7201 |
| Brand / Manufacturer | HIMA |
| Product Category | Circuit Breaker — Infeed Fuse Board Module |
| Series | H7201 Power Distribution Series |
| Rated Current | 16A |
| Voltage Rating | 240V AC / 60V DC |
| Breaking Capacity | 10kA @ 240V AC |
| Trip Mechanism | Thermal-Magnetic |
| Mounting Type | DIN Rail (35mm) |
| Protection Class | IP20 |
| Operating Temperature | -25°C to +70°C |
| Mechanical Life | >20,000 operations |
| Standards | IEC 60947-2, UL 489 |
| Country of Origin | Germany |
| Condition | New & Original — Factory Sealed |
| Warranty | 12 Months |
Professional Logistics & Sourcing Excellence
Every HIMA ETA2210 16A H7201 unit dispatched from our facility ships in original factory packaging with full traceability documentation, including batch records and conformance certificates. For time-critical plant shutdowns, same-day dispatch is available on confirmed in-stock units — contact our logistics team before 14:00 local time to qualify.
We maintain dedicated global supply channels for EOL (End-of-Life) and legacy HIMA modules, ensuring that facilities operating older H7201 board generations are not exposed to obsolescence risk. Our sourcing network spans authorized distribution partners across Europe, Asia-Pacific, and the Americas, enabling worldwide express logistics with typical transit times of 3-7 business days to major industrial hubs.
All units undergo pre-shipment continuity and insulation resistance verification. Export documentation, including commercial invoices, packing lists, and certificates of origin, is prepared in compliance with international trade regulations to eliminate customs clearance delays.
Engineering Support & FAQ
Q1: What is the correct installation sequence for the ETA2210 16A H7201 on an H7201 infeed fuse board?
A: De-energize the H7201 board and verify absence of voltage using a calibrated meter. Align the breaker’s DIN rail clip with the 35mm rail, apply firm downward pressure until the clip audibly engages, then connect load wiring per HIMA H7201 terminal assignment diagrams. Re-energize and verify trip flag is in the reset (closed) position before applying load.
Q2: Which HIMA firmware versions are compatible with H7201 boards using this breaker?
A: The ETA2210 16A H7201 is a passive protection device and is firmware-independent. Compatibility is determined by the H7201 board hardware revision, not the HIMA controller firmware version. Consult your H7201 board revision documentation for channel current ratings.
Q3: How do I initiate a warranty claim for a defective unit?
A: Contact sale@ninermas.com with your order reference, unit serial number, and a brief fault description. Our technical team will issue a Return Merchandise Authorization (RMA) within 1 business day. Confirmed defective units are replaced or refunded within the 12-month warranty period.
Q4: Can this breaker be used as a direct replacement in non-HIMA DIN rail applications?
A: Yes, provided the application voltage and current ratings are within the ETA2210 16A H7201 specifications (16A, 240V AC / 60V DC, 10kA breaking capacity). Verify trip characteristic compatibility with your system’s coordination study before installation.
Q5: What proof-test procedure is recommended for IEC 61511 compliance?
A: Apply a calibrated overload current of 1.45 rated current (23.2A) for the duration specified in the ETA2210 datasheet. Record trip time and compare against factory tolerance bands. Document results in your functional safety management system. Contact our engineering support team for test procedure templates.
Q6: Are spare DIN rail clips or terminal accessories available?
A: Standard 35mm DIN rail clips are included with each unit. Additional terminal covers, phase barriers, and labeling accessories compatible with the H7201 board are available — contact sale@ninermas.com for accessory part numbers and pricing.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667
| Product Series | Other Modules |
|---|---|
| Country of Origin | DE |
Catalog Continuation
More HIMA modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within SIS Safety & Redundancy Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.