Original Industrial Spare Part

GE Multilin T35-E00HUH-F8N-H6C-MXX-PXX-UXX-WXX Transformer Protection Relay

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: T35-E00HUH-F8N-H6C-MXX-PXX-UXX-WXX PLC & Industrial Automation Modules GE

RFQ Ready

Request pricing & availability

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

GE Multilin T35-E00HUH-F8N-H6C-MXX-PXX-UXX-WXX | Reliable Automation Component

Field Application & Operational Analysis

From the perspective of a Site Reliability Engineer managing high-availability power infrastructure, the T35-E00HUH-F8N-H6C-MXX-PXX-UXX-WXX stands as a cornerstone automation component in mission-critical transformer protection schemes. Deployed across transmission substations and industrial power networks, this GE Multilin UR-series digital relay delivers sub-20ms fault clearance via its percentage-restraint differential algorithm — directly reducing unplanned outage windows and safeguarding transformer assets valued in the millions. Its role in process optimization is measurable: facilities integrating this relay into their protection architecture report significantly improved system availability metrics and reduced mean-time-to-repair (MTTR) during fault events.

Engineered for operational excellence in harsh industrial environments, the T35-E00HUH-F8N-H6C-MXX-PXX-UXX-WXX operates reliably across a thermal range of -40°C to +85°C, making it suitable for outdoor switchgear enclosures, tropical substations, and arctic-grade installations alike. During commissioning, SREs should verify CT polarity and vector group compensation settings via EnerVista UR Setup software prior to energization. Rack-mount installation (482.6mm — 177.8mm — 254mm) follows standard 19-inch panel conventions, and grounding must comply with IEC 60255 shielding requirements to suppress EMI in high-voltage bays.

As a strategic spare-parts holding, this relay is indispensable for any facility operating GE Multilin UR-platform protection systems. End-of-life (EOL) procurement cycles for legacy substation equipment make pre-positioning a unit on the shelf a proven risk-mitigation strategy — eliminating lead-time exposure during emergency replacement scenarios and ensuring seamless integration with existing I/O modules and communication infrastructure.

Key Operational Features

High-Speed Differential Protection — Percentage-restraint algorithm with 2nd & 5th harmonic blocking; response <20ms for internal faults, minimizing transformer damage.
Redundancy & High Availability — Dual-redundant power supply compatibility and watchdog self-diagnostics ensure continuous relay availability in 24/7 operational environments.
Seamless System Integration — Native IEC 61850 GOOSE messaging, Modbus TCP/RTU, and DNP3 enable plug-and-play integration with existing SCADA and DCS architectures.
Adaptive Vector Group Compensation — Automatic phase-shift correction for Yy, Yd, Dy, Dd, Yz configurations eliminates manual offset calculations during commissioning.
Restricted Earth Fault (REF) Detection — Sensitive winding-fault detection capability identifies incipient ground faults before they escalate to catastrophic failures.
Thermal Overload Monitoring — Continuous thermal capacity tracking extends transformer insulation life and supports predictive maintenance workflows.

Maintenance & Performance Benchmarks

The T35-E00HUH-F8N-H6C-MXX-PXX-UXX-WXX is architected to scale across diverse industrial network topologies — from single-bus radial distribution feeders to complex ring-bus and breaker-and-a-half substation configurations. Its modular I/O expansion architecture supports up to 8 phase CT inputs plus 4 ground CT channels, accommodating two-winding and three-winding transformer protection within a single chassis.

For maintenance teams, the relay’s onboard event recorder (512 events) and oscillography capture (64 samples/cycle) provide forensic-grade data for post-fault analysis — a critical capability for root-cause investigations in regulated utility environments. Firmware upgrades are field-deployable via Ethernet without relay de-energization, minimizing maintenance windows. Calibration intervals follow IEC 60255-1 recommendations, typically every 5 years under normal operating conditions.

In multi-relay protection architectures, GOOSE-based inter-relay communication enables zone-selective interlocking (ZSI) with upstream and downstream I/O modules, achieving fault isolation in under 30ms — a benchmark that directly supports operational excellence targets in high-availability industrial networks.

Comprehensive Data Sheet

Attribute Technical Data
Full Model Number T35-E00HUH-F8N-H6C-MXX-PXX-UXX-WXX
Manufacturer GE Multilin (General Electric)
Product Series Multilin UR (Universal Relay)
Protection Functions Transformer Differential, Overcurrent (TOC/IOC), Restricted Earth Fault (REF), Thermal Overload
Rated Auxiliary Voltage 100-240V AC/DC
Operating Temperature -40°C to +85°C
CT Inputs Up to 8 phase + 4 ground
Digital Inputs 16 configurable
Digital Outputs 12 relay contacts
Differential Algorithm Percentage restraint with 2nd & 5th harmonic blocking
Fault Response Time <20ms (differential)
Communication Protocols IEC 61850 (GOOSE/MMS), Modbus TCP/RTU, DNP3
Mounting Style 19-inch rack / panel mount
Dimensions (W H D) 482.6mm — 177.8mm — 254mm
Weight 5 kg
Compliance Standards IEC 60255, IEEE C37.91, IEC 61850, UL/CSA
Cybersecurity IEC 62351, Role-Based Access Control, Encrypted Comms
Country of Origin United States
Warranty 12 Months

Professional Logistics & Sourcing Excellence

Every unit of the T35-E00HUH-F8N-H6C-MXX-PXX-UXX-WXX dispatched from our facility is shipped in Original Factory Packaging — sealed anti-static enclosures with OEM documentation, calibration certificates, and firmware version records intact. This preserves warranty validity and ensures traceability for regulated utility and industrial procurement audits.

For time-critical plant shutdowns and emergency maintenance scenarios, same-day dispatch is available for in-stock units (order confirmation before 14:00 CST). We maintain a dedicated global supply pipeline for EOL and legacy GE Multilin UR-platform modules — sourced through authorized distribution channels to guarantee authenticity. Worldwide express logistics via DHL, FedEx, and UPS ensures delivery to North America, Europe, Southeast Asia, and the Middle East within 3-7 business days.

All export documentation — including commercial invoices, packing lists, and certificates of origin — is prepared in compliance with international trade regulations, streamlining customs clearance for cross-border procurement teams.

Engineering Support & FAQ

Q1: What are the step-by-step installation requirements for the T35-E00HUH-F8N-H6C-MXX-PXX-UXX-WXX?
A: Mount the relay in a 19-inch rack using the supplied hardware. Connect auxiliary power (100-240V AC/DC) to the rear terminal block. Wire CT and VT inputs per the wiring diagram in the GE Multilin UR Installation Manual (GEK-113000). Configure vector group compensation and protection settings via EnerVista UR Setup software over Ethernet or RS-485. Perform secondary injection testing before energizing. Total commissioning time for experienced technicians: 4-6 hours.

Q2: Which firmware versions are compatible with this relay model?
A: The T35-E00HUH-F8N-H6C-MXX-PXX-UXX-WXX supports UR firmware versions 7.x and above. Firmware upgrades are available via GE Grid Solutions’ EnerVista platform. Always verify firmware compatibility with your existing UR-series chassis and I/O modules before upgrading. Contact our technical team for firmware version verification specific to your unit’s serial number.

Q3: How does the warranty claim process work?
A: Our 12-month warranty covers manufacturing defects and workmanship failures under normal operating conditions. To initiate a claim, contact sale@ninermas.com with your order number, unit serial number, and a description of the fault symptom. Our engineering team will conduct a remote diagnostic assessment within 24 hours. Confirmed warranty cases receive a replacement unit dispatch or repair service at no additional cost.

Q4: Can this relay integrate with third-party SCADA systems via DNP3?
A: Yes. The T35-E00HUH-F8N-H6C-MXX-PXX-UXX-WXX supports DNP3 Level 2 compliance over serial (RS-485) and Ethernet (TCP/IP). Data point mapping is fully configurable via EnerVista. The relay has been validated for integration with OSIsoft PI, GE iFIX, Wonderware, and Siemens WinCC SCADA platforms in multi-vendor substation automation environments.

Q5: Is the relay suitable for three-winding transformer protection?
A: Yes. The UR T35 platform natively supports three-winding transformer differential protection with independent restraint and operate current calculations for each winding. The H6C hardware option in the model string T35-E00HUH-F8N-H6C-MXX-PXX-UXX-WXX confirms the CT/VT input configuration required for three-winding applications.

Q6: What cybersecurity measures are built into this relay?
A: The relay implements IEC 62351-8 role-based access control (RBAC), TLS-encrypted Ethernet communications, comprehensive audit logging, and NERC CIP-compliant configuration management. These features make it suitable for deployment in critical infrastructure environments subject to regulatory cybersecurity requirements.


© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667

Product Series

Multilin

Country of Origin

US

Reviews

There are no reviews yet.

Be the first to review “GE Multilin T35-E00HUH-F8N-H6C-MXX-PXX-UXX-WXX Transformer Protection Relay”

Your email address will not be published. Required fields are marked

Catalog Continuation

More GE modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack