Original Industrial Spare Part

GE IS230SNRTH2A IS200SRTDH2ACB Service-Ready Spare Part

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: IS230SNRTH2A IS200SRTDH2ACB PLC & Industrial Automation Modules GE

RFQ Ready

Pricing by RFQ

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

GE IS230SNRTH2A IS200SRTDH2ACB Service-Ready Spare Part for Industrial Maintenance

The GE IS230SNRTH2A and its companion board IS200SRTDH2ACB are critical control modules within the GE Mark VI Turbine Control System — one of the most widely deployed distributed control architectures in power generation, oil & gas, and heavy industrial facilities worldwide. When either of these boards fails or degrades, the consequences extend far beyond a single card replacement: the entire turbine control loop is at risk, and unplanned downtime can cost thousands of dollars per hour. NINERMAS maintains verified, service-ready stock of both modules to support emergency replacement, scheduled overhaul, and long-term spare parts inventory programs.

Whether you are a maintenance engineer responding to a fault alarm at 2 AM or a procurement engineer building a strategic spare parts list for the next annual shutdown, this listing provides the original GE hardware you need — tested before shipment, backed by a 12-month warranty, and supported by a team with deep experience in Mark VI ecosystem components.

Spare Maintenance Table

Parameter IS230SNRTH2A IS200SRTDH2ACB
Manufacturer GE (General Electric) GE (General Electric)
Series / Platform Mark VI Turbine Control Mark VI Turbine Control
Module Function Simplex Network & Relay Terminal Board Simplex Relay Terminal / Distribution Board
Typical Application Gas turbine, steam turbine, generator control panels Relay output distribution, I/O interface in Mark VI cabinet
Operating Voltage 24 VDC (nominal, from Mark VI backplane) 24 VDC (nominal, from Mark VI backplane)
Operating Temperature 0°C to 60°C 0°C to 60°C
Mounting DIN rail / Mark VI cabinet backplane DIN rail / Mark VI cabinet backplane
Compatibility GE Mark VI, Mark VIe control systems GE Mark VI, Mark VIe control systems
Condition Original, tested before shipment Original, tested before shipment
Warranty 12 Months 12 Months
Lead Time In stock — ships within 2 business days In stock — ships within 2 business days
Maintenance Recommendation Inspect relay contacts and backplane connectors every 12 months; replace if contact resistance exceeds spec Verify relay output continuity and terminal torque during annual shutdown

Maintenance Planning for Continuous Operation

Experienced maintenance engineers know that replacing the IS230SNRTH2A or IS200SRTDH2ACB in isolation rarely tells the full story. These boards sit at the intersection of power distribution, relay output, and I/O signal routing within the Mark VI cabinet — meaning a fault in one module often stresses adjacent components. A thorough site replacement should always include a systematic inspection of the surrounding control cabinet ecosystem.

Start with the power supply modules feeding the Mark VI backplane — boards such as the IS200EPBAG1A power distribution module or equivalent 24 VDC bulk power supplies. A degraded power supply can cause intermittent faults that mimic board-level failures, leading to unnecessary replacements. Verify output voltage stability under load before condemning the IS230SNRTH2A.

Next, inspect the I/O terminal boards connected to the same control loop. The IS200TBCIH2C and similar terminal board assemblies share the same wiring harness and connector ecosystem as the SRTD series. Loose or corroded terminal connections on these boards can introduce ground faults or signal noise that propagates back to the relay module. Torque all terminal screws to specification and check for insulation breakdown on field wiring.

The communication and network modules within the Mark VI cabinet — including IS230SNCAH1A network communication boards — should also be verified during any relay board replacement. A failed or marginal network card can prevent the controller from properly acknowledging relay state changes, creating diagnostic confusion during commissioning after the repair.

For facilities running redundant or TMR (Triple Modular Redundant) Mark VI configurations, replacing one relay terminal board requires verifying that the redundant channels — often served by companion boards like the IS200SRLYH1B relay output board — are synchronized and healthy. A mismatch in relay states between redundant channels can trigger protective trips even after a successful board swap.

Do not overlook the fuse and protection components within the cabinet. Blade fuses, miniature circuit breakers, and surge protection devices on the 24 VDC rail should be inspected and replaced on a scheduled basis — typically every 3–5 years or following any overcurrent event. A blown fuse that went undetected may have been the root cause of the original board failure.

Finally, if the Mark VI system interfaces with an HMI or operator workstation running GE’s ToolboxST or CIMPLICITY software, confirm that the I/O configuration database reflects the correct board revision after replacement. Mismatched firmware or configuration files between the physical hardware and the software model can cause unexpected behavior during the first turbine start after maintenance.

NINERMAS can supply a broad range of Mark VI ecosystem components — including backplane assemblies, I/O boards, power modules, relay output cards, and communication modules — to support complete cabinet restocking programs. Contact our team to discuss multi-part procurement packages and volume pricing.

Site Replacement Workflow

Step 1 — Fault Isolation: Use ToolboxST diagnostics to confirm the IS230SNRTH2A or IS200SRTDH2ACB as the fault source. Document the active alarm codes and I/O channel states before powering down the cabinet section.

Step 2 — Safe Isolation: Follow your site’s lockout/tagout (LOTO) procedure for the affected Mark VI cabinet section. Verify that the turbine is in a safe hold state and that redundant control channels (if applicable) have assumed control before isolating the faulty board.

Step 3 — Physical Replacement: Remove the faulty board by releasing the backplane connector latch and sliding the module out of its slot. Install the replacement IS230SNRTH2A or IS200SRTDH2ACB, ensuring the backplane connector is fully seated. Torque any retaining screws to the manufacturer’s specification.

Step 4 — Configuration Verification: Before restoring power, confirm that the replacement board’s hardware revision is compatible with the installed ToolboxST configuration file. If the revision differs, update the I/O configuration database accordingly to avoid mismatch faults on startup.

Step 5 — Functional Test: Restore power to the cabinet section and monitor the ToolboxST diagnostic screen for board health status. Exercise each relay output channel through the HMI to verify correct operation. Confirm that all I/O points associated with the replaced board are reading correctly before returning the turbine to service.

Step 6 — Documentation: Record the replacement in your CMMS (Computerized Maintenance Management System), including the old board’s serial number, the new board’s serial number, the date of replacement, and the technician’s name. Update your spare parts inventory to trigger a reorder for the consumed module.

Spare Parts Support FAQ

Q1: How do I confirm that the IS230SNRTH2A or IS200SRTDH2ACB I receive is compatible with my specific Mark VI configuration?
Compatibility depends on the hardware revision level and the ToolboxST software version running on your controller. When placing your order, provide NINERMAS with your existing board’s part number suffix (e.g., H2A, H2ACB) and your ToolboxST version. Our technical team will cross-reference the revision history to confirm compatibility before shipment. All boards are tested against standard Mark VI backplane interfaces prior to dispatch.

Q2: What does the 12-month warranty cover, and what is the replacement process if a board fails in service?
The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions as defined by GE’s Mark VI installation and maintenance guidelines. If a board fails within the warranty period, contact NINERMAS at sale@ninermas.com with your order number and a description of the fault. We will arrange a replacement shipment — in most cases within 2 business days — to minimize your downtime exposure. Boards damaged by overvoltage, incorrect installation, or environmental conditions outside the specified operating range are evaluated on a case-by-case basis.

Q3: Should I keep one or two spare units of each board in my on-site inventory?
For critical turbine control applications, the industry best practice is to maintain a minimum of one spare unit per installed board type, with two spares recommended for facilities running single-string (simplex) Mark VI configurations where no redundant channel exists. For TMR systems, one spare per board type is generally sufficient given the built-in redundancy. NINERMAS offers volume pricing for multi-unit spare parts packages — contact our team to discuss a tailored inventory program aligned with your annual maintenance budget.

Q4: Can NINERMAS supply IS230SNRTH2A and IS200SRTDH2ACB boards for long-term or repeat procurement programs?
Yes. NINERMAS maintains ongoing stock of Mark VI series components and can support blanket purchase orders, annual supply agreements, and emergency spot purchases. We understand that GE Mark VI systems have long operational lifespans — often 20 years or more — and that sourcing original spare parts becomes increasingly challenging as the product line matures. Our procurement network is specifically structured to support long-term industrial maintenance programs, ensuring you have access to verified original hardware for the life of your installation.

Product Series

Mark VI

Country of Origin

US

Catalog Continuation

Nearby part numbers around IS230SNR.

Use this lane when the buyer is comparing adjacent model numbers, revision-near items, or closely related spare variants within the same brand family.

Open this lane

Catalog Continuation

More GE modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack