Original Industrial Spare Part
Siemens 6SL3955-0TX00-1AA2 Retrofit Thyristor Module
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU6SL3955-0TX00-1AA2
- CategoryPLC & Industrial Automation Modules
- BrandSiemens
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Siemens 6SL3955-0TX00-1AA2 Retrofit Thyristor Module with SKU 6SL3955-0TX00-1AA2.
Siemens 6SL3955-0TX00-1AA2 Retrofit Thyristor Module: Legacy System Compatible Upgrade
The Siemens 6SL3955-0TX00-1AA2 is a ruggedized thyristor module engineered for demanding industrial environments and designed to serve as a retrofit-compatible replacement within legacy SINAMICS drive platforms. As production lines age and original equipment manufacturers discontinue support for older drive components, the 6SL3955-0TX00-1AA2 provides a reliable, drop-in upgrade path that preserves existing control architecture while delivering improved thermal resilience and electrical performance. NINERMAS maintains verified stock of this module with full 12-month warranty coverage, enabling rapid deployment for both planned maintenance windows and emergency breakdown scenarios.
Industrial facilities operating legacy Siemens SINAMICS S120 or SINAMICS G series drive cabinets frequently encounter the challenge of sourcing discontinued thyristor and power semiconductor modules. The 6SL3955-0TX00-1AA2 addresses this directly — its mechanical footprint, terminal layout, and backplane interface are compatible with the original chassis slot, reducing the engineering effort required during a retrofit. Engineers planning a control cabinet upgrade should verify DC bus voltage ratings, gate trigger signal compatibility, and cooling airflow direction before installation, as minor generational differences in SINAMICS power stacks can affect thermal management requirements.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| SKU / Part Number | 6SL3955-0TX00-1AA2 |
| Brand / Series | Siemens SINAMICS |
| Module Type | Ruggedized Thyristor Power Module |
| Backplane Interface | Compatible with SINAMICS S120 power stack backplane; verify slot assignment with drive commissioning tool |
| Installation Requirement | Standard DIN rail or chassis slot mounting; confirm clearance for heat sink and airflow |
| Communication Compatibility | Operates within DRIVE-CLiQ topology; compatible with CU320-2 and CU310-2 Control Units |
| Replacement Recommendation | Direct replacement for equivalent legacy thyristor modules in SINAMICS S120 Booksize and Chassis format drives |
| Commissioning Notes | Re-parameterize motor data set (MDS) and encoder interface after module swap; verify p0100 frequency setting |
| Warranty | 12 Months — NINERMAS COMPANY LIMITED |
Retrofit Planning for Existing Automation Systems
A successful retrofit involving the 6SL3955-0TX00-1AA2 requires a structured pre-installation audit of the existing drive cabinet. Begin by documenting the current power supply module — typically a Siemens 6SL3100-series Active Line Module or Basic Line Module — to confirm that DC bus capacity is sufficient to support the replacement thyristor module under full load conditions. Undersized line modules are a common cause of nuisance trips after a module swap and must be addressed before commissioning.
Terminal wiring should be mapped against the original as-built drawings. The 6SL3955-0TX00-1AA2 uses standard SINAMICS power terminal assignments, but aging cabinets may have field-modified wiring that deviates from factory schematics. Pay particular attention to PE (protective earth) bonding, motor cable shielding termination, and the routing of DRIVE-CLiQ cables connecting the module to the Control Unit — such as the CU320-2 DP or CU320-2 PN — and any downstream Motor Modules like the 6SL3120 or 6SL3130 series.
For systems that include a Siemens SIMATIC S7-300 or S7-400 PLC communicating with the drive via PROFIBUS-DP or PROFINET, verify that the GSD/GSDML device description file loaded in the PLC project matches the drive firmware version after the module replacement. Mismatched GSD files can cause communication faults that appear unrelated to the hardware swap. If the site is migrating from PROFIBUS to PROFINET as part of a broader protocol upgrade, this retrofit window is an appropriate time to install a PROFINET-capable Control Unit and update the HMI project — whether running on a Siemens TP700 Comfort, TP1200 Comfort, or a PC-based WinCC Runtime panel — to reflect the new device addressing.
I/O expansion requirements should also be reviewed during the planning phase. If the legacy system relied on a Siemens 6ES7 series SM321 digital input module or SM331 analog input module for process feedback, confirm that signal ranges and terminal assignments remain compatible with the new drive configuration. In cases where the original system used a separate signal isolator or barrier module between field instruments and the drive analog inputs, retain these components to protect the new thyristor module from ground loop interference and overvoltage events.
Backplane slot addressing must be re-confirmed after physical installation. SINAMICS drive systems assign component addresses automatically via DRIVE-CLiQ enumeration, but the order in which modules are powered up can affect address assignment in multi-axis configurations. Use STARTER or Siemens TIA Portal with the Startdrive engineering package to perform a topology comparison and resolve any address conflicts before enabling the drive. Programming cables such as the PC Adapter USB A2 or PROFIBUS PC adapter should be on-site during commissioning to allow direct parameter access if network communication is not yet restored.
Downtime Control During System Migration
Minimizing production downtime during a thyristor module replacement requires advance preparation that begins well before the scheduled maintenance window. The original PLC program — whether residing in a Siemens S7-300, S7-400, or S7-1500 controller — should be backed up to both the programming device and an offline archive before any hardware is disturbed. Drive parameters should be uploaded from the existing module using STARTER or TIA Portal Startdrive and saved as a project file, so that the full parameter set — including speed controller gains, ramp times, motor nameplate data, and safety function configurations — can be restored to the replacement 6SL3955-0TX00-1AA2 without manual re-entry.
Where process continuity is critical, consider a staged migration approach: install and pre-commission the replacement module in a parallel test configuration before the live cutover. This allows functional verification of the motor control response, encoder feedback, and safety relay integration without exposing the production line to extended downtime. For drives controlling conveyor systems, pumps, or compressors where a hard stop is unacceptable, coordinate the cutover with the process control team to identify a safe low-load window.
After physical installation, perform a controlled first-run sequence at reduced speed setpoint to verify current feedback, temperature sensor readings, and fault-free DRIVE-CLiQ communication before ramping to full production speed. Document all parameter changes made during commissioning and update the as-built cabinet drawings to reflect the new module part number and any wiring modifications. This documentation supports future maintenance cycles and reduces troubleshooting time if a fault occurs after the retrofit is complete.
Retrofit Support FAQ
Q1: Is the 6SL3955-0TX00-1AA2 a direct drop-in replacement for the original thyristor module in my SINAMICS S120 drive?
In most SINAMICS S120 Chassis and Booksize power stack configurations, the 6SL3955-0TX00-1AA2 is mechanically and electrically compatible with the original slot. However, customers should verify the DC bus voltage class, cooling method (forced air vs. liquid), and firmware version of the Control Unit before installation. NINERMAS technical support can assist with compatibility confirmation based on your existing drive order number.
Q2: What commissioning steps are required after installing the replacement module?
After physical installation and DRIVE-CLiQ cable reconnection, perform a topology scan using TIA Portal Startdrive or STARTER software. Restore the saved parameter set to the new module, verify motor data set (MDS) entries, and run a motor identification routine if the original data is unavailable. Confirm safety function (STO/SS1) wiring and test emergency stop response before returning the drive to automatic mode.
Q3: Does NINERMAS provide pre-shipment testing for the 6SL3955-0TX00-1AA2?
Yes. All modules supplied by NINERMAS undergo functional verification prior to dispatch, including power-on testing and visual inspection for transport damage. Units are shipped with original or equivalent protective packaging. A 12-month warranty is provided from the date of invoice, covering manufacturing defects and premature failure under normal operating conditions.
Q4: What is the typical lead time and stock availability?
NINERMAS maintains inventory of the 6SL3955-0TX00-1AA2 to support urgent breakdown and planned maintenance requirements. Standard orders are processed within 1–3 business days. For large-quantity or project-based procurement, contact our sales team to confirm allocation and arrange consolidated shipment. Emergency same-day dispatch may be available for critical production stoppages — contact us directly to discuss your timeline.
| Product Series | SINAMICS |
|---|---|
| Country of Origin | DE |
Catalog Continuation
More Siemens modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: 6AV2123-2JB03-0AX0
Siemens 6AV2123-2JB03-0AX0 Retrofit HMI for KP700 Basic
SKU: 6FC5303-0AF22-0AA1
Siemens 6FC5303-0AF22-0AA1 Safety-Reliable CNC Operator Panel
SKU: 6SE7090-0XX84-1CJ0
Siemens 6SE7090-0XX84-1CJ0 Retrofit-Compatible Drive for Legacy Systems
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: MMC-SD-12.0-460-D
KOLLMORGEN MMC-SD-12.0-460-D Retrofit-Compatible Servo Drive
SKU: BM-DP12 1070075887-202