Original Industrial Spare Part
GE IC695ETM001-HT Service-Ready Spare Part for Industrial Maintenance
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUIC695ETM001-HT
- CategoryDCS Distributed Control Systems
- BrandGE Fanuc / Emerson
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: GE IC695ETM001-HT Service-Ready Spare Part for Industrial Maintenance with SKU IC695ETM001-HT.
GE IC695ETM001-HT Service-Ready Spare Part for Industrial Maintenance
The GE IC695ETM001-HT is an original Ethernet transmit module designed for the GE PACSystems RX3i control platform — one of the most widely deployed PLC architectures in process automation, discrete manufacturing, and critical infrastructure. As a service-ready spare part, the IC695ETM001-HT is engineered to restore Ethernet communication capability to RX3i backplane systems with minimal downtime. Whether you are managing a scheduled annual overhaul, responding to an unplanned communication fault, or building a proactive spare parts inventory, this module delivers the compatibility, reliability, and long-term supply assurance that maintenance and procurement engineers demand.
Sourced from verified supply channels and subject to pre-shipment functional testing, every IC695ETM001-HT unit shipped by NINERMAS undergoes inspection to confirm module integrity before dispatch. Our 12-month warranty covers manufacturing defects and ensures your maintenance team has recourse if any issue arises post-installation. With global logistics support and long-term stock availability, NINERMAS is positioned as a dependable supply partner for facilities that cannot afford communication gaps in their control architecture.
Spare Maintenance Table
| Parameter | Specification / Detail |
|---|---|
| Part Number | IC695ETM001-HT |
| Brand | GE Fanuc / Emerson Automation Solutions |
| Series | PACSystems RX3i (IC695 Series) |
| Module Type | Ethernet Communication Module |
| Network Interface | 10/100 Mbps Ethernet (RJ-45) |
| Backplane Compatibility | IC695CHS007, IC695CHS012, IC695CHS016 and compatible RX3i backplanes |
| CPU Compatibility | IC695CPE302, IC695CPE305, IC695CPE310, IC695CPE330, IC695CPE400 |
| Operating Temperature | 0°C to 60°C (standard industrial range) |
| Mounting | RX3i backplane slot — no external wiring required for module power |
| Communication Protocols | SRTP, Modbus TCP, EtherNet/IP (read), OPC (via CPU) |
| Origin | United States |
| Condition | Original / Service-Ready |
| Pre-Shipment Testing | Yes — functional inspection before dispatch |
| Warranty | 12 Months |
| Lead Time | In Stock — ships within 1–3 business days |
| Long-Term Supply | Yes — available for ongoing procurement programs |
Maintenance Planning for Continuous Operation
When an IC695ETM001-HT fails or is flagged during a control cabinet inspection, the communication fault rarely exists in isolation. Experienced maintenance engineers know that Ethernet module degradation in an RX3i system is often accompanied by related stress on adjacent components. A thorough site assessment should extend beyond the module itself.
Begin by verifying the IC695PSA040 or IC695PSD040 power supply module — an unstable DC rail is one of the most common root causes of intermittent Ethernet faults in RX3i cabinets. Inspect the IC695CHS016 backplane for physical damage, corrosion on the slot contacts, or signs of thermal stress, particularly in high-cycle environments. If the system uses a IC695CPE330 or IC695CPE400 CPU, confirm that firmware is current and that the CPU’s Ethernet port configuration aligns with the replacement module’s IP settings.
For systems with distributed I/O, check the IC695ALG608 analog input modules and IC695MDL654 discrete output modules for any latent faults that may have been masked by the communication outage. If the cabinet includes a IC695CMM002 serial communication module for legacy device integration, verify that its configuration remains intact after the Ethernet module swap — some firmware versions require a CPU restart to re-initialize all communication modules simultaneously.
Signal integrity should also be assessed at the terminal block and field wiring level. Loose connections on I/O terminal strips, degraded shielding on instrumentation cables, or failed surge protection devices on analog signal lines can introduce noise that manifests as communication errors at the Ethernet layer. If the system includes signal isolators between field instruments and the RX3i I/O modules, inspect these for drift or failure — particularly in environments with high electromagnetic interference.
For facilities running Proficy HMI/SCADA or a third-party HMI connected via Ethernet to the RX3i CPU, confirm that the HMI polling configuration and tag database remain synchronized after the module replacement. An IP address change or MAC address update on the new IC695ETM001-HT may require HMI reconfiguration to restore full supervisory visibility. Similarly, if the plant uses an IC695PBM300 PROFIBUS master module or IC695CMX128 motion control module, verify that these modules resume normal operation after the CPU re-establishes Ethernet communication.
Procurement engineers building annual maintenance budgets should consider stocking the IC695ETM001-HT alongside complementary spares: the IC695PSA040 power supply, at least one spare IC695CPE302 or CPE305 CPU for older installations, and a set of IC695MDL740 discrete input modules for high-wear I/O positions. A well-structured spare parts list reduces mean time to repair (MTTR) and protects production continuity across multi-shift operations.
Site Replacement Workflow
Step 1 — Pre-Replacement Verification: Before removing the faulty IC695ETM001-HT, document the module’s current IP address, subnet mask, gateway, and any SRTP or Modbus TCP connection parameters configured in the CPU’s hardware configuration (HWC). Export the current project from Proficy Machine Edition or the applicable programming environment to ensure a verified backup exists.
Step 2 — Safe Module Removal: Place the RX3i CPU in STOP mode. If the system supports hot-swap for the ETM001 slot (verify with your specific CPU firmware version), follow GE’s hot-swap procedure. Otherwise, power down the backplane before removing the module. Ground yourself with an ESD wrist strap before handling the replacement unit.
Step 3 — Module Installation and Configuration: Insert the IC695ETM001-HT into the designated backplane slot. Power up the system and use Proficy Machine Edition to download the hardware configuration to the CPU. Assign the correct IP address to the new module — note that the IC695ETM001-HT does not retain configuration locally; all network parameters are stored in the CPU project.
Step 4 — Communication Verification: Ping the module’s IP address from the engineering workstation to confirm network presence. Open the Proficy Machine Edition online diagnostics and verify that the ETM001 module status shows “OK” with no fault codes. Confirm that all SCADA, HMI, and remote I/O connections have re-established successfully before returning the CPU to RUN mode.
Step 5 — Post-Replacement Documentation: Record the replacement date, new module serial number, and any configuration changes in the site maintenance log. Update the spare parts inventory to reflect the consumed unit and initiate a reorder if stock falls below the minimum threshold defined in your maintenance plan.
This workflow is applicable to both emergency replacements following unplanned downtime and scheduled swap-outs during planned maintenance windows. The IC695ETM001-HT’s direct form-fit-function compatibility with the RX3i backplane eliminates the need for hardware modifications, reducing replacement time to under 30 minutes for experienced technicians.
Spare Parts Support FAQ
Q1: Is the IC695ETM001-HT compatible with all RX3i PACSystems backplanes and CPU versions?
The IC695ETM001-HT is designed for the GE PACSystems RX3i platform and is compatible with standard IC695 series backplanes including the IC695CHS007, IC695CHS012, and IC695CHS016. Compatibility with specific CPU firmware versions should be verified against GE’s hardware compatibility matrix. NINERMAS recommends confirming your CPU model and firmware revision before ordering to ensure seamless integration. Our technical team can assist with compatibility verification upon request.
Q2: What pre-shipment testing does NINERMAS perform on the IC695ETM001-HT before dispatch?
Every IC695ETM001-HT unit undergoes a functional inspection prior to shipment. This includes visual inspection for physical damage, verification of module identification markings, and basic power-on testing where applicable. Units that do not pass inspection are quarantined and not dispatched. All shipped units are covered by a 12-month warranty against manufacturing defects, providing procurement engineers with confidence in the quality of each spare part received.
Q3: Can NINERMAS support long-term or blanket purchase orders for the IC695ETM001-HT?
Yes. NINERMAS maintains ongoing stock of the IC695ETM001-HT and supports long-term supply agreements for facilities with recurring maintenance requirements. We work with maintenance and procurement teams to establish scheduled delivery programs, reducing the risk of stockouts during critical maintenance windows. Contact our sales team at sale@ninermas.com to discuss volume pricing, lead time commitments, and blanket order arrangements.
Q4: What is the recommended spare parts inventory strategy for facilities running GE RX3i PACSystems?
For facilities where RX3i systems are critical to production continuity, we recommend maintaining a minimum of one IC695ETM001-HT per active control cabinet as a hot spare. In addition, a comprehensive RX3i spare parts strategy should include at least one spare CPU module, one power supply module, and a selection of high-wear I/O modules relevant to your specific application. Annual review of spare parts consumption data helps refine inventory levels and prevents both stockouts and excess carrying costs. NINERMAS can provide guidance on building a cost-effective spare parts list tailored to your installed base.
| Product Series | Fanuc |
|---|---|
| Country of Origin | US |
Catalog Continuation
More GE Fanuc / Emerson modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within DCS Distributed Control Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: KJ2005X1-BK1 SE3007
Emerson KJ2005X1-BK1 SE3007 Service-Ready Spare Part
SKU: NPOW-62C 64113429B
ABB NPOW-62C 64113429B Service-Ready Spare Part for Industrial Maintenance