Original Industrial Spare Part
METRIX TXR-33505 Retrofit-Compatible Safety Module
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUTXR-33505
- CategoryTSI & Rotating Machinery Monitoring
- BrandMetrix
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: METRIX TXR-33505 Retrofit-Compatible Safety Module with SKU TXR-33505.
METRIX TXR-33505 Retrofit-Compatible Safety Module for Legacy Systems
The METRIX TXR-33505 is a ruggedized safety module engineered for industrial vibration monitoring and machinery protection applications. As legacy control systems age and original equipment manufacturers discontinue support for older hardware generations, the TXR-33505 has become a critical retrofit solution for maintenance engineers managing rotating equipment protection in power generation, oil and gas, petrochemical, and heavy manufacturing environments. Whether you are replacing a failed unit in an emergency shutdown scenario or executing a planned upgrade of an aging machinery protection rack, the TXR-33505 delivers the electrical compatibility, signal integrity, and installation footprint required to restore system continuity with minimal downtime.
Sourced as an original METRIX component and fully tested prior to shipment, every TXR-33505 unit supplied by NINERMAS is backed by a 12-month warranty and supported by long-term inventory availability — giving procurement engineers the confidence to plan multi-year spare parts programs without exposure to supply chain disruption.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| SKU / Part Number | TXR-33505 |
| Brand / Manufacturer | METRIX Instrument Co. |
| Series | TXR Vibration Transmitter / Safety Module Series |
| Product Type | Ruggedized Safety Module / Vibration Monitor |
| Primary Function | Machinery protection, vibration signal conditioning, safety shutdown interface |
| Signal Input Compatibility | Compatible with standard eddy-current proximity probes and velocity transducers used in legacy METRIX racks |
| Output Interface | 4–20 mA analog output; relay contact outputs for alarm and danger thresholds |
| Installation Format | DIN-rail or panel-mount; confirm rack slot dimensions against existing enclosure before installation |
| Power Supply Requirement | 24 VDC nominal; verify existing cabinet power rail capacity before retrofit |
| Communication Compatibility | Hardwired I/O; confirm signal wiring compatibility with existing DCS or PLC input cards |
| Replacement Suitability | Direct retrofit for legacy TXR-series and compatible METRIX machinery protection modules |
| Commissioning Notes | Verify probe gap voltage, alarm setpoints, and relay logic before returning to service |
| Operating Environment | Ruggedized for harsh industrial environments; confirm ambient temperature and vibration ratings against site conditions |
| Warranty | 12 Months — NINERMAS Quality Assurance |
| Availability | In stock; long-term supply program available |
Retrofit Planning for Existing Automation Systems
A successful TXR-33505 retrofit begins well before the module arrives on site. Maintenance engineers should start by auditing the existing machinery protection rack to confirm the number of occupied slots, the current wiring scheme for each channel, and the power supply headroom available in the control cabinet. In many legacy installations, the 24 VDC rail serving the METRIX rack is shared with other instrumentation — including signal isolators, terminal barrier strips, and loop-powered transmitters — so verifying that the power supply can sustain the additional load of a replacement module is a non-negotiable first step.
Wiring documentation is equally critical. The TXR-33505 interfaces with proximity probe drivers or velocity transducers mounted on rotating machinery, and the field cable routing, shielding practice, and terminal block assignments must be confirmed against the original loop drawings before any module swap. In installations where the original wiring records are incomplete or missing, engineers should perform a point-to-point continuity check and re-document the terminal assignments before proceeding.
On the control system side, the analog output from the TXR-33505 feeds into DCS analog input cards or PLC I/O modules. Before the retrofit, confirm that the receiving card’s input range (typically 4–20 mA) and channel configuration match the module’s output specification. If the existing DCS uses a HART-capable input card, verify whether the TXR-33505’s output is HART-transparent or requires a dedicated signal isolator in the loop. In some older installations, a signal conditioner or galvanic isolator is already present between the machinery protection rack and the DCS marshalling cabinet — these components should be inspected and replaced if they show signs of drift or insulation degradation.
The relay output wiring deserves particular attention during retrofit planning. The TXR-33505 provides alarm and danger relay contacts that typically feed into the plant’s emergency shutdown system or safety instrumented system relay logic. Before disconnecting the old module, map the relay contact assignments, confirm the coil voltage and contact rating, and verify that the replacement module’s relay specifications are compatible with the existing interposing relay panel or safety relay module in the cabinet. In SIL-rated applications, the retrofit must be reviewed against the safety requirements specification before the module is returned to service.
For sites running older METRIX monitoring racks alongside modern Bently Nevada 3500-series or Emerson CSI machinery health systems, the TXR-33505 retrofit may also be an opportunity to evaluate whether a communication gateway or protocol converter is needed to bridge legacy hardwired signals into a modern condition monitoring platform. Similarly, if the plant’s HMI screens display vibration trend data sourced from the machinery protection rack, the HMI tag configuration and alarm limits should be reviewed and updated to reflect the replacement module’s calibration.
Finally, confirm that the replacement module’s firmware or hardware revision is compatible with any existing rack-level communication backplane or multiplexer if the installation uses a networked machinery protection architecture. NINERMAS maintains long-term inventory of TXR-33505 units and can support multi-unit procurement for sites planning a phased rack upgrade across multiple machine trains.
Downtime Control During System Migration
Minimizing unplanned downtime during a TXR-33505 replacement requires a structured pre-outage preparation protocol. Begin by scheduling the module swap during a planned maintenance window aligned with the machine’s inspection cycle — avoid hot-swap attempts on live machinery unless the system architecture explicitly supports it and the safety review has been completed.
Before the outage window opens, prepare a complete replacement kit: the TXR-33505 module, a set of spare terminal screws and ferrules, a calibrated loop calibrator for 4–20 mA verification, a proximity probe gap voltage meter, and a copy of the original loop drawings. Having all materials staged at the cabinet eliminates the most common source of extended downtime — technicians leaving the work area to retrieve tools or documentation.
During the swap, photograph the existing wiring before disconnecting any terminals. Label each wire with its terminal number and signal description using adhesive cable markers. This practice protects the original program logic and alarm configuration from transcription errors and provides a reliable reference if the replacement module requires any wiring adjustment.
After installation, perform a bench-level functional check: apply a simulated probe signal, verify the 4–20 mA output at the DCS input card, and confirm that the alarm and danger relay contacts operate at the correct setpoints. Only after this verification should the machine be returned to service. Document the as-found and as-left conditions, update the maintenance management system record, and file the replacement module’s test certificate with the equipment history file.
For sites with multiple identical machine trains — such as compressor stations, pump skids, or turbine halls — NINERMAS recommends maintaining a minimum of one TXR-33505 unit per machine train in the site spare parts store. This inventory posture eliminates the lead-time risk associated with emergency procurement and ensures that the next unplanned failure can be resolved within the planned maintenance window rather than extending into a production-impacting outage.
Retrofit Support FAQ
Q1: Is the TXR-33505 a direct drop-in replacement for older METRIX TXR-series modules?
The TXR-33505 is designed as a retrofit-compatible replacement within the METRIX TXR machinery protection family. Before installation, verify the terminal wiring assignments, relay contact configuration, and output signal range against your existing loop drawings. Minor wiring adjustments may be required depending on the specific legacy variant being replaced. NINERMAS can provide technical support to assist with compatibility verification prior to shipment.
Q2: What testing is performed before shipment?
Every TXR-33505 unit supplied by NINERMAS undergoes functional testing prior to dispatch, including output signal verification and relay contact operation checks. A test certificate is included with each shipment. Units are packaged in anti-static, shock-protected packaging to ensure they arrive in field-ready condition.
Q3: Can NINERMAS support long-term supply for multi-site or multi-year procurement programs?
Yes. NINERMAS maintains dedicated inventory of TXR-33505 units and can support blanket purchase orders, scheduled release programs, and multi-site spare parts contracts. Contact our team to discuss volume pricing, lead-time commitments, and consignment stock arrangements for critical spare parts programs.
Q4: What is covered under the 12-month warranty?
The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions. It does not cover damage resulting from incorrect installation, overvoltage, or environmental conditions outside the module’s rated specification. NINERMAS provides replacement or repair support for any warranty claim, with priority processing for sites experiencing production-critical failures.
| Product Series | Other series |
|---|
Catalog Continuation
More Metrix modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: MX8030-080-00-05/MX8031-080-00-05
Metrix MX8030-080-00-05 Retrofit Extension Cable Module
Catalog Continuation
Alternative parts within TSI & Rotating Machinery Monitoring.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 943-A-120V60-TR-PC 0270-20069 CPA-1
MKS MLS-943-A-120V60-TR-PC-0270-20069-CPA-1 Service-Ready Spare Part for Industrial Maintenance
SKU: 330103-02-07-10-02-00
Bently Nevada 330103-02-07-10-02-00 Safety-Reliable Proximity Probe
SKU: 21000-16-10-00-098-04-02
Bently Nevada 21000-16-10-00-098-04-02 Retrofit Proximity Probe Housing
SKU: 0610520IF120243B