Original Industrial Spare Part
Honeywell CC-MCAR01 Spare Part for Experion PKS C300 Maintenance
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUCC-MCAR01 51403892-100 51403884-100
- CategorySIS Safety & Redundancy Systems
- BrandHoneywell
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Honeywell CC-MCAR01 Spare Part for Experion PKS C300 Maintenance with SKU CC-MCAR01 51403892-100 51403884-100.
Honeywell CC-MCAR01 Spare Part for Experion PKS C300 Maintenance
The Honeywell CC-MCAR01 (Part Numbers: 51403892-100 / 51403884-100) is a controller redundancy module engineered for the Experion PKS C300 Distributed Control System platform. As a service-ready spare part, it is designed to restore system redundancy, eliminate single points of failure, and support continuous process operation in demanding industrial environments including oil & gas, petrochemical, power generation, pulp & paper, and advanced manufacturing facilities.
Maintaining an available stock of the CC-MCAR01 is a critical element of any proactive maintenance strategy for Experion PKS installations. Unplanned controller failures without a qualified replacement on hand can result in extended process shutdowns, production losses, and costly emergency procurement. NINERMAS supplies this module as a tested, verified spare with full 12-month warranty coverage, ensuring your maintenance team can execute rapid field replacement with confidence.
Spare Maintenance Table
| Parameter | Specification / Detail |
|---|---|
| Part Number | CC-MCAR01 / 51403892-100 / 51403884-100 |
| Brand | Honeywell |
| Series / Platform | Experion PKS — C300 Controller |
| Module Function | Controller Redundancy Module (MCAR) |
| Redundancy Type | Hot standby / bumpless switchover |
| Communication Interface | FTE (Fault Tolerant Ethernet) backbone |
| Mounting | C300 Controller chassis / backplane slot |
| Power Supply Requirement | Supplied via backplane (CC-PWR01 / CC-PWR02 series) |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Humidity | 5% to 95% RH, non-condensing |
| Compatibility | Honeywell Experion PKS R310 and above; C300 controller family |
| Installation Environment | Industrial control cabinet, DCS marshalling room |
| Pre-shipment Testing | Functional power-on and communication verification |
| Warranty | 12 months from date of shipment |
| Supply Program | Long-term spare parts availability; committed stock on request |
Maintenance Planning for Continuous Operation
When scheduling replacement or inspection of the CC-MCAR01 redundancy module, maintenance engineers should treat the activity as part of a broader C300 controller health audit. The redundancy module does not operate in isolation — its performance is directly dependent on the integrity of adjacent components within the same control cabinet and FTE network segment.
Begin by verifying the condition of the CC-PWR01 or CC-PWR02 power supply modules that feed the C300 chassis. A degraded power supply is one of the most common root causes of redundancy switchover events and should be inspected or replaced concurrently. Next, confirm the health of the CC-TCNT01 or CC-TCNT02 communication interface modules that manage FTE connectivity; a faulty communication module can mask redundancy faults or prevent proper failover detection.
I/O integrity is equally important. Inspect the CC-PAIH01, CC-PAOH01, and CC-PDOB01 I/O modules connected to the C300 for signs of channel drift, blown fuses, or terminal block corrosion. Loose or oxidized wiring on I/O terminal assemblies (CC-TAIX11, CC-TAOX11) can introduce intermittent faults that are often misattributed to the controller itself. Replacing the CC-MCAR01 without addressing wiring integrity will not resolve underlying signal quality issues.
For facilities running Experion PKS with Safety Manager integration, also verify the status of SM-SCM01 Safety Communication Modules and associated safety I/O modules. Any redundancy event on the C300 side may trigger safety system alerts that require coordinated reset procedures. Ensure that FTE network switches (Honeywell-qualified managed switches) are operating within specification, as network latency or packet loss directly impacts redundancy synchronization performance.
During annual shutdowns, it is best practice to include the CC-MCAR01 in a full controller module rotation alongside the C300 controller module (CC-CONT01) itself. Keeping a tested spare of both the controller and its redundancy module on the shelf eliminates the most critical single points of failure in the DCS architecture. Procurement engineers should also consider stocking CC-SCMB01 system cabinet backplane assemblies for aging installations where backplane connector wear may be a factor.
Site Replacement Workflow
Replacing the CC-MCAR01 in a live Experion PKS environment requires careful sequencing to avoid unplanned process interruption. The following workflow is recommended for maintenance teams performing a hot-standby module swap:
Step 1 — Pre-replacement verification: Confirm in Experion Station that the primary C300 controller is in the ACTIVE state and the redundant controller is in STANDBY. Verify that the FTE network shows no existing faults. Document the current firmware revision of the installed CC-MCAR01 to ensure the replacement module carries a compatible or higher firmware version.
Step 2 — Module extraction: On the STANDBY controller chassis, power down the redundancy module slot following Honeywell’s documented hot-swap procedure. Extract the faulty CC-MCAR01 carefully, avoiding contact with backplane connectors. Inspect the backplane slot for debris, bent pins, or corrosion before inserting the replacement.
Step 3 — Replacement insertion and synchronization: Insert the new CC-MCAR01 (51403892-100 / 51403884-100) into the designated slot. The module will initiate an automatic synchronization sequence with the active controller. Monitor Experion Station for the STANDBY SYNCHRONIZED status confirmation before returning the system to normal redundant operation. This process typically completes within 2–5 minutes depending on controller database size.
Step 4 — Post-replacement validation: Perform a controlled switchover test to confirm that the new module assumes the ACTIVE role correctly and that the previously active controller transitions to STANDBY without process upset. Log the replacement in the site maintenance management system (CMMS) and update the spare parts inventory record.
This workflow minimizes downtime to under 15 minutes for a qualified technician and eliminates the need for a full process shutdown in most applications.
Spare Parts Support FAQ
Q1: Is the CC-MCAR01 (51403892-100) compatible with all Experion PKS C300 revisions?
The CC-MCAR01 is compatible with Experion PKS Release R310 and all subsequent releases through current versions. For installations running releases prior to R310, firmware compatibility should be verified against the Honeywell Experion PKS compatibility matrix. NINERMAS can provide firmware version documentation upon request to support pre-installation verification.
Q2: What pre-shipment testing is performed on the CC-MCAR01 before delivery?
Every CC-MCAR01 unit supplied by NINERMAS undergoes functional power-on testing and communication interface verification prior to shipment. Units are inspected for physical integrity, connector condition, and firmware operability. A test report is available upon request. All units ship with a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions.
Q3: Can NINERMAS support long-term or committed stock programs for the CC-MCAR01?
Yes. NINERMAS offers long-term spare parts supply agreements for the CC-MCAR01 and the broader Experion PKS C300 module family. Committed stock programs allow procurement engineers to reserve inventory against planned annual maintenance cycles or multi-year service contracts, reducing lead time risk for obsolete or allocation-constrained parts. Contact our team to discuss volume and lead time commitments.
Q4: What should I do if the replacement CC-MCAR01 does not achieve STANDBY SYNCHRONIZED status after installation?
If the module fails to synchronize, first verify that the FTE network connections on both controller chassis are secure and that the FTE switches show no fault indicators. Check that the replacement module firmware version is compatible with the active controller. If the issue persists, perform a controlled power cycle of the standby chassis only. NINERMAS technical support is available to assist with troubleshooting, and any unit confirmed defective within the warranty period will be replaced at no charge.
| Product Series | Experion PKS |
|---|---|
| Country of Origin | US |
Catalog Continuation
Likely Experion PKS platform matches.
These parts are closer to the same platform family signaled by the current SKU and title, so buyers can validate continuity before sending a final RFQ.
Catalog Continuation
More Honeywell modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within SIS Safety & Redundancy Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: MINI-PS/12-24DC/5-15DC/2 2320018
Phoenix Contact MINI-PS/12-24DC/5-15DC/2 2320018 DC Power Supply