Original Industrial Spare Part

FLENDER 2T2A-05400-011 Retrofit BAVIPO Controller

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: 2T2A-05400-011 TSI & Rotating Machinery Monitoring FLENDER

RFQ Ready

Pricing by RFQ

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

FLENDER 2T2A-05400-011 Retrofit BAVIPO Controller: Legacy System Retrofit and Smooth Upgrade Path

The FLENDER 2T2A-05400-011 is a core controller module within the FLENDER BAVIPO vibration monitoring and protection platform, engineered for continuous operation in rotating equipment environments including gearboxes, couplings, compressors, and drive trains. As legacy BAVIPO installations approach end-of-service life, the 2T2A-05400-011 remains one of the most sought-after retrofit-compatible replacement units for plants that must maintain operational continuity without committing to a full system overhaul.

For maintenance engineers and procurement specialists managing aging automation infrastructure, sourcing a verified original 2T2A-05400-011 is critical. This controller interfaces directly with the BAVIPO sensor network, processes vibration amplitude and frequency data, and outputs protection signals to the connected drive or shutdown relay. Its form factor, terminal layout, and firmware logic are fully compatible with existing BAVIPO-series enclosures, making it a drop-in replacement candidate for most installations without requiring panel redesign or PLC reprogramming.

Upgrade Compatibility Table

Parameter Details
SKU / Part Number 2T2A-05400-011
Brand / Series FLENDER BAVIPO
Module Function Vibration Monitoring Controller
Mounting Interface DIN-rail / Panel-mount (BAVIPO enclosure compatible)
Power Supply Input 24 VDC nominal (verify existing PSU capacity before swap)
Communication Interface PROFIBUS DP / Analog signal output (site-specific)
Terminal Compatibility Compatible with existing BAVIPO terminal block wiring
Replacement Scope Direct replacement for end-of-life 2T2A-05400-011 units
Commissioning Requirement Parameter verification via BAVIPO configuration tool
Warranty 12 Months from date of shipment (NINERMAS)

Retrofit Planning for Existing Automation Systems

Successful integration of the FLENDER 2T2A-05400-011 into an existing BAVIPO installation requires a structured pre-replacement assessment. Before removing the failed or degraded unit, engineers should document the current parameter set using the BAVIPO configuration interface, noting alarm thresholds, trip setpoints, and channel assignments. This data must be re-entered into the replacement module during commissioning to ensure protection logic continuity.

Power supply capacity is the first checkpoint. The 2T2A-05400-011 draws from the panel’s 24 VDC bus, typically shared with other BAVIPO modules such as the FLENDER 2T2A-05400-012 signal conditioning card and the FLENDER 2T2A-05400-013 output relay module. Verify that the existing DIN-rail 24 VDC power supply — often a Phoenix Contact or Siemens SITOP unit — can sustain the combined load after the replacement module is inserted. Undersized power supplies are a common cause of intermittent faults post-retrofit.

Terminal wiring on the BAVIPO backplane follows a fixed assignment scheme. The 2T2A-05400-011 occupies a defined slot within the BAVIPO rack, and its sensor input terminals connect directly to the FLENDER BAVIPO-2 piezoelectric sensor modules mounted on the gearbox or coupling housing. Before disconnecting the old unit, photograph or sketch the terminal connections and verify cable labeling. Incorrect sensor channel assignment after replacement will produce erroneous vibration readings and may trigger nuisance trips.

For plants running PROFIBUS DP networks, the 2T2A-05400-011 must be assigned the correct node address matching the original configuration in the Siemens S7-300 or S7-400 PLC project. Address conflicts on the PROFIBUS segment will prevent the controller from communicating with the upstream SCADA or DCS. If the site has migrated to PROFINET, a PROFIBUS-to-PROFINET gateway module may be required to bridge the legacy BAVIPO network to the new control backbone.

HMI screens linked to the BAVIPO system — whether running on a Siemens TP700 Comfort panel or an older OP270 operator panel — reference specific data block addresses for vibration values and alarm states. After replacing the 2T2A-05400-011, confirm that the HMI tag mapping remains intact and that vibration trend displays update correctly during the post-installation test run. If the site uses a Siemens SINAMICS S120 drive system with integrated condition monitoring, verify that the drive’s CU320-2 control unit still receives valid vibration status signals from the BAVIPO network following the swap.

I/O expansion considerations apply when the 2T2A-05400-011 replacement is part of a broader panel upgrade. If additional vibration channels are being added — for example, to monitor a newly installed FLENDER ZAPEX coupling or an additional gearbox stage — the BAVIPO rack may require an additional I/O expansion card. Plan rack space and DIN-rail allocation before ordering to avoid installation delays. Signal isolators between the BAVIPO output and the PLC analog input cards are recommended when cable runs exceed 20 metres to prevent ground loop interference.

Downtime Control During System Migration

Minimising production downtime during a BAVIPO controller replacement requires advance preparation and a clear sequence of steps. The replacement of the 2T2A-05400-011 is typically achievable within a planned maintenance window of two to four hours, provided the replacement unit has been pre-tested and all parameters have been documented in advance.

Begin by placing the drive or machine in a safe, de-energised state following site lockout/tagout procedures. Remove the failed 2T2A-05400-011 from the BAVIPO rack, noting the slot position and any jumper or DIP switch settings on the board. Install the replacement unit in the same slot, restore terminal connections, and power up the BAVIPO system before reconnecting the drive. This sequence allows the BAVIPO controller to initialise and self-test independently, confirming sensor signal integrity before the machine is restarted.

Retain the original PLC program logic without modification during the controller swap. The 2T2A-05400-011 replacement does not require changes to the Siemens S7 program, provided the PROFIBUS node address and I/O mapping are preserved. If the site’s control system has been upgraded to a Siemens S7-1500 with TIA Portal, verify that the BAVIPO GSD file is correctly imported and that the hardware configuration reflects the replacement module’s firmware version.

Post-installation, conduct a full vibration baseline measurement with the machine running at normal operating speed. Compare the readings against historical trend data to confirm that the replacement 2T2A-05400-011 is measuring correctly. Document the commissioning results and update the site’s maintenance records. NINERMAS provides a 12-month warranty on all shipped units, and pre-shipment functional testing is conducted on every 2T2A-05400-011 before dispatch to reduce the risk of infant failure on site.

Retrofit Support FAQ

Q1: Is the FLENDER 2T2A-05400-011 a direct replacement for the original unit without hardware modification?
In most BAVIPO installations, the 2T2A-05400-011 is a direct slot-compatible replacement. No hardware modification to the rack or panel is required. Parameter re-entry via the BAVIPO configuration tool is necessary to restore the original alarm and trip setpoints.

Q2: What commissioning steps are required after installing the replacement 2T2A-05400-011?
After installation, restore all vibration alarm thresholds, trip levels, and channel assignments using the BAVIPO configuration interface. Verify PROFIBUS node address assignment, confirm HMI tag mapping, and conduct a baseline vibration measurement at normal operating speed before returning the machine to production.

Q3: How is terminal wiring compatibility confirmed before ordering?
Provide the existing BAVIPO rack model and the slot position of the failed unit. NINERMAS technical support can cross-reference the terminal assignment drawing to confirm wiring compatibility before shipment. Photographs of the existing installation are also accepted for pre-order verification.

Q4: What warranty and stock availability does NINERMAS offer for the 2T2A-05400-011?
NINERMAS maintains stock of the FLENDER 2T2A-05400-011 and conducts pre-shipment functional testing on every unit. A 12-month warranty from the date of shipment is provided. Contact the NINERMAS sales team for current lead times and quantity availability.

Product Series

Other series

Catalog Continuation

Alternative parts within TSI & Rotating Machinery Monitoring.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack