Original Industrial Spare Part

KARL 52004-1-030-DNG-3/6-TS-WS-0130-76142-DIP180 Service Spare

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: 52004-1.030 DNG 3-6/TS WS 0130-76142 DIP180 0100-76142 W/ 0020-78718 0100-77040 PLC & Industrial Automation Modules KARL

RFQ Ready

Pricing by RFQ
  • SKU52004-1.030 DNG 3-6/TS WS 0130-76142 DIP180 0100-76142 W/ 0020-78718 0100-77040
  • CategoryPLC & Industrial Automation Modules
  • BrandKARL
  • SupportAvailability, lead time, condition, and shipping coordination

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

KARL 52004-1-030-DNG-3/6-TS-WS-0130-76142-DIP180 Service Spare: Critical Replacement for Industrial Fan Systems

The KARL 52004-1-030-DNG-3/6-TS-WS-0130-76142-DIP180 is an original service-ready spare part manufactured by Karl Klein, a leading German producer of industrial fans, blowers, and ventilation systems. This component belongs to the DNG 3/6 series — a robust line of industrial fans widely deployed in control cabinet cooling, process ventilation, machine tool enclosures, and automation panel thermal management across manufacturing, energy, and heavy industry sectors.

When this part fails or reaches end-of-service life, the consequences extend far beyond a single fan unit. Overheating in control cabinets, PLC enclosures, and drive panels can cascade into unplanned downtime, damaged electronics, and costly production losses. Maintaining a verified, service-ready stock of the 52004-1-030-DNG-3/6-TS-WS-0130-76142-DIP180 is a fundamental element of any proactive maintenance strategy for facilities running Karl Klein ventilation systems.

NINERMAS supplies this part as an original spare with full pre-shipment electrical and mechanical inspection, backed by a 12-month warranty from the date of delivery. Each unit is verified for dimensional accuracy, motor winding integrity, and operational performance before dispatch — ensuring your maintenance team receives a part that is ready to install, not just ready to ship.

Spare Maintenance Table

Parameter Details
Part Number / SKU 52004-1.030 DNG 3-6/TS WS 0130-76142 DIP180 / 0100-76142 / W/ 0020-78718 / 0100-77040
Brand / Manufacturer KARL (Karl Klein Ventilatorenbau GmbH, Germany)
Series DNG 3/6
Product Type Industrial Fan / Blower Spare Part
Origin Germany (DE)
Voltage Rating Refer to nameplate / DNG 3/6 series specification
Insulation Class DIP180 (Class H equivalent, 180°C thermal rating)
Compatibility Karl Klein DNG 3/6 series fan assemblies; control cabinet ventilation systems; industrial enclosure cooling
Installation Environment Industrial indoor; control cabinet; machine enclosure; process ventilation panel
Maintenance Interval Inspect every 6–12 months; replace per OEM schedule or upon performance degradation
Pre-Shipment Testing Electrical continuity, insulation resistance, mechanical run-test
Warranty 12 months from date of delivery
Supply Availability Long-term stock; suitable for annual maintenance contracts and emergency procurement

Maintenance Planning for Continuous Operation

Replacing the 52004-1-030-DNG-3/6-TS-WS-0130-76142-DIP180 in the field is rarely an isolated task. Experienced maintenance engineers understand that a fan failure in a control cabinet is often a symptom of broader thermal stress across the enclosure. A thorough site inspection during replacement should encompass the full thermal and electrical ecosystem of the affected panel.

Begin by auditing the Karl Klein DNG 3/6 motor assembly and impeller for wear, imbalance, or bearing fatigue — these components share the same service cycle and should be evaluated simultaneously. Check the DNG series fan housing gasket and inlet filter mat for blockage or deterioration; a clogged filter is frequently the root cause of premature fan motor failure and is often overlooked during reactive maintenance.

On the electrical side, inspect the motor protection relay or thermal overload relay associated with the fan circuit. If the fan has been running in an overloaded or thermally stressed condition, the relay may have experienced nuisance trips or degraded calibration. Similarly, verify the power contactor controlling the fan motor — contact erosion and coil degradation are common in high-cycle fan applications.

For cabinets housing frequency inverters or variable speed drives (such as those from Siemens, ABB, or Lenze), confirm that the drive’s internal cooling fan and heat sink are also serviceable. Drive overheating is a leading cause of unplanned shutdowns in automated production lines, and the DNG series fan is often the first line of thermal defense for these components.

Review the terminal blocks and wiring connections within the fan circuit. Vibration from continuous fan operation can loosen terminal screws over time, leading to intermittent faults or increased contact resistance. A torque check on all fan circuit terminals is recommended during any planned replacement event.

If the control cabinet includes signal isolators or I/O modules mounted near the fan zone, inspect these for heat-related discoloration or connector oxidation. Elevated ambient temperatures caused by inadequate ventilation can silently degrade analog signal accuracy and digital I/O response times. Additionally, check any fuse holders and miniature circuit breakers in the fan supply circuit — thermal cycling can cause fuse element fatigue even without a visible overcurrent event.

For facilities running HMI panels or operator terminals in the same enclosure, verify that display brightness, touch response, and backlight function remain within specification. Thermal stress from a failed fan can accelerate HMI component aging, particularly in legacy systems where replacement parts are increasingly scarce.

Finally, document the replacement event in your maintenance management system, noting the part number, installation date, pre-replacement condition, and any associated components inspected. This record supports warranty claims, audit compliance, and future procurement planning for the Karl Klein DNG series spare parts inventory.

Site Replacement Workflow

Step 1 — Isolation and Safety: De-energize the control cabinet and lock out / tag out (LOTO) the fan supply circuit. Verify zero voltage at the fan motor terminals using a calibrated multimeter before proceeding.

Step 2 — Documentation: Photograph the existing fan installation, wiring routing, and terminal connections. Record the existing part number from the nameplate and cross-reference with the replacement unit (52004-1-030-DNG-3/6-TS-WS-0130-76142-DIP180) to confirm dimensional and electrical compatibility.

Step 3 — Removal: Disconnect the fan motor leads from the terminal block. Remove the fan mounting hardware (typically M4 or M5 screws on DNG 3/6 series). Extract the fan assembly carefully to avoid damaging adjacent wiring or PCB-mounted components.

Step 4 — Inspection of Mounting Surface: Clean the fan mounting aperture and inspect the cabinet cutout for corrosion, deformation, or gasket residue. Replace the inlet filter mat if present and degraded.

Step 5 — Installation: Mount the replacement fan unit, ensuring correct airflow direction (intake vs. exhaust) as per the original installation. Reconnect motor leads to the correct terminals, observing phase sequence for three-phase variants. Torque all fasteners to specification.

Step 6 — Commissioning: Re-energize the circuit and verify fan operation: correct rotation direction, absence of abnormal vibration or noise, and stable current draw within nameplate rating. Confirm cabinet internal temperature returns to normal operating range within the expected time window.

Step 7 — Record Closure: Update the maintenance log with the replacement date, new part serial number, and next scheduled inspection interval. Flag the replaced unit for failure analysis if root cause investigation is required.

Spare Parts Support FAQ

Q1: Is the 52004-1-030-DNG-3/6-TS-WS-0130-76142-DIP180 an original Karl Klein part or an aftermarket equivalent?
This is an original Karl Klein spare part, not an aftermarket or third-party substitute. NINERMAS sources and stocks genuine OEM components to ensure full compatibility with existing DNG 3/6 series installations. Each unit is supplied with original part markings and is eligible for the 12-month warranty.

Q2: What is the recommended inventory strategy for this part in a high-availability facility?
For facilities with multiple Karl Klein DNG series fans in service, we recommend maintaining a minimum of one to two units of the 52004-1-030-DNG-3/6-TS-WS-0130-76142-DIP180 in local stock at all times. Given the end-of-life status of many legacy Karl Klein series, lead times from OEM channels can be unpredictable. NINERMAS offers reserved inventory agreements and long-term supply contracts to support annual maintenance planning and emergency procurement requirements.

Q3: How is compatibility verified before shipment?
NINERMAS performs a pre-shipment compatibility check based on the customer’s declared application: cabinet model, existing part number, and installation environment. Each unit undergoes electrical continuity testing, insulation resistance measurement (Megger test), and a mechanical run-test before packaging. A test report is available upon request for quality-critical applications.

Q4: What does the 12-month warranty cover, and how is a warranty claim processed?
The 12-month warranty covers manufacturing defects, premature electrical failure under normal operating conditions, and dimensional non-conformance. It does not cover damage resulting from incorrect installation, overvoltage, contamination, or unauthorized modification. To initiate a warranty claim, contact NINERMAS with the original invoice, installation date, and a description of the failure mode. Replacement or credit will be processed within the agreed service timeline.

Product Series

Other series

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.