Original Industrial Spare Part

SIEMENS 6SL3352-1AG38-8FA1 Retrofit-Compatible Drive Module for Legacy Systems

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: 6SL3352-1AG38-8FA1 PLC & Industrial Automation Modules Siemens

RFQ Ready

Pricing by RFQ

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

SIEMENS 6SL3352-1AG38-8FA1 Retrofit-Compatible Drive Module for Legacy Systems

The SIEMENS 6SL3352-1AG38-8FA1 is a high-performance drive module within the SINAMICS S120 series, engineered for demanding motion control and servo drive applications in industrial automation environments. As legacy production lines age and original spare parts become increasingly difficult to source, the 6SL3352-1AG38-8FA1 serves as a critical retrofit and replacement solution for facilities operating older SINAMICS S120 infrastructure. Whether you are managing a controlled migration from an end-of-life drive platform or responding to an unplanned failure on the production floor, this module provides the electrical compatibility, mechanical fit, and firmware alignment required to restore operations with minimal disruption.

At NINERMAS, we specialize in sourcing, testing, and supplying discontinued and hard-to-find industrial control components. Every unit of the 6SL3352-1AG38-8FA1 we supply undergoes functional verification prior to shipment, ensuring that the module you receive is ready for installation and commissioning. We maintain inventory specifically to support customers facing urgent retrofit timelines, and our technical team is available to assist with compatibility verification, terminal wiring guidance, and commissioning support throughout the replacement process.

Upgrade Compatibility Table

Parameter Details
SKU / Part Number 6SL3352-1AG38-8FA1
Series SINAMICS S120
Brand Siemens
Module Type Drive Module (Motor Module / Power Unit)
Installation Format Booksize / Chassis — confirm rack and backplane slot dimensions before installation
Communication Interface DRIVE-CLiQ; compatible with S120 Control Units (e.g., CU320-2 DP, CU320-2 PN)
Backplane / Rack Compatibility Compatible with standard SINAMICS S120 drive line-up; verify DC bus connector and shared DC link configuration
Replacement Suitability Direct retrofit for equivalent S120 motor modules; cross-reference legacy part numbers with Siemens migration guide
Commissioning Tool STARTER / SINAMICS Startdrive (TIA Portal); parameter backup recommended before swap
Firmware Compatibility Verify firmware version alignment with existing CU and ALM/SLM units on the same DC bus
Terminal Wiring Confirm motor power terminals (U2/V2/W2), encoder interface, and safety relay wiring against original drawings
Warranty 12 Months from date of shipment — covers manufacturing defects and functional failure under normal operating conditions

Retrofit Planning for Existing Automation Systems

Successful integration of the 6SL3352-1AG38-8FA1 into an existing automation system requires a structured pre-installation assessment. Before the replacement module arrives on site, engineers should document the current drive configuration using the STARTER commissioning tool or SINAMICS Startdrive within TIA Portal, exporting all parameter sets and drive object configurations. This backup is essential — it protects the original motion logic and eliminates the need to reprogram axis parameters from scratch after the swap.

Power supply capacity is the first hardware checkpoint. The SINAMICS S120 Active Line Module (ALM) or Basic Line Module (BLM) feeding the DC bus must have sufficient headroom to support the 6SL3352-1AG38-8FA1’s rated output current. If the existing line module is already operating near capacity due to other motor modules on the same shared DC link — such as a 6SL3120-1TE21-0AA3 or 6SL3120-1TE23-0AA3 — a load calculation review is mandatory before commissioning the replacement unit.

Terminal wiring adaptation is the next critical step. Technicians must compare the motor power terminals (U2, V2, W2), PE grounding point, and DC bus connector (P600/M600) of the replacement module against the original installation drawings. Where the legacy module used a different terminal pitch or connector housing, appropriate adapter terminals or re-crimped cables will be required. The encoder interface — typically a DRIVE-CLiQ cable connecting to the motor’s encoder module or a Sensor Module Cabinet-Mounted (SMC) such as the 6SL3055-0AA00-5BA3 — must also be verified for cable length and connector type compatibility.

For systems that include a SINAMICS S120 Control Unit CU320-2 DP or CU320-2 PN, the DRIVE-CLiQ topology must be re-established after module replacement. The control unit automatically detects connected drive objects via DRIVE-CLiQ during power-up; however, if the module address or drive object ID has changed, the topology comparison in STARTER or Startdrive will flag a mismatch. Engineers should be prepared to accept the new topology or restore the saved configuration to resolve this. In multi-axis systems where the 6SL3352-1AG38-8FA1 operates alongside other motor modules on a shared booksize line-up, the physical slot position and DRIVE-CLiQ port assignment must match the original configuration to avoid axis mapping errors in the PLC program.

HMI screens connected via PROFIBUS DP or PROFINET — for example, a SIMATIC HMI TP1200 Comfort or a legacy OP177B panel — typically reference drive parameters through the PLC’s symbol table rather than directly. As long as the PLC program and drive parameter set are restored correctly, HMI displays for speed feedback, torque limits, and fault codes should resume normal operation without screen-level modifications. However, if the legacy system used direct PROFIBUS communication between the HMI and the drive, the drive’s PROFIBUS node address must be confirmed and set identically to the replaced unit.

I/O expansion modules within the control cabinet — such as a SIMATIC ET 200SP distributed I/O station or a 6ES7138-4CA01-0AA0 motor starter module — are generally unaffected by the drive module swap, provided the PLC program logic and network configuration remain unchanged. Signal isolators used on analog speed reference or torque reference inputs should be checked for correct scaling after the replacement, particularly if the new module has a different analog input impedance specification.

Finally, installation space must be confirmed. The 6SL3352-1AG38-8FA1 must fit within the existing cabinet cutout and mounting rail allocation. Cooling airflow clearances above and below the module must meet Siemens specifications to prevent thermal shutdown during operation. If the control cabinet uses a shared cooling fan unit or a SINAMICS S120 Cabinet Module arrangement, airflow baffles and fan assignments should be inspected as part of the retrofit preparation.

Downtime Control During System Migration

Minimizing production downtime during a drive module replacement is a primary concern for any plant maintenance team. The most effective strategy is to complete all pre-commissioning preparation — parameter backup, wiring documentation, spare cable preparation, and firmware version verification — before the production line is taken offline. When the 6SL3352-1AG38-8FA1 arrives from NINERMAS, it should already be confirmed as the correct replacement through part number cross-reference and, where possible, a bench power-on test using a compatible control unit.

During the physical swap, the DC bus must be fully discharged before any terminals are disconnected. The SINAMICS S120 system includes a DC bus discharge indicator, but a calibrated multimeter measurement across the P600 and M600 terminals is recommended as a secondary safety check. Once the replacement module is mechanically installed and all terminals are reconnected, the DRIVE-CLiQ cable should be the last connection made before power-up.

On first power-up, the control unit will perform a DRIVE-CLiQ topology scan. If the parameter backup was correctly restored, the system should transition to ready state without requiring manual re-parameterization. A no-load test run — commanding the axis to a low speed setpoint without mechanical load — should be performed before reconnecting the motor to the driven machine. This confirms that current limits, speed controller gains, and encoder feedback are functioning correctly within the restored parameter set.

For facilities with strict change management requirements, NINERMAS can provide shipment documentation including serial number records and pre-shipment test reports to support maintenance logs and audit trails. Our 12-month warranty covers the replacement unit from the date of shipment, providing assurance throughout the post-installation monitoring period.

Retrofit Support FAQ

Q1: Is the 6SL3352-1AG38-8FA1 a direct drop-in replacement for my existing SINAMICS S120 motor module?
In most cases, yes — provided the power rating, DC bus voltage class, and physical format (booksize or chassis) match your existing installation. We recommend cross-referencing the full part number and confirming the rated output current against your motor nameplate data before ordering. Our technical team can assist with compatibility verification if you provide your existing module’s part number and motor specifications.

Q2: What commissioning steps are required after installing the replacement module?
After physical installation and terminal reconnection, restore your previously exported parameter set using STARTER or SINAMICS Startdrive. Perform a DRIVE-CLiQ topology acceptance if prompted, then conduct a no-load test run to verify speed feedback, current limits, and fault-free operation before reconnecting the mechanical load. Safety function validation (STO, SS1, SLS) should also be re-tested if your application uses integrated safety.

Q3: Does NINERMAS test units before shipment, and what does the 12-month warranty cover?
Yes. Every unit undergoes functional verification prior to dispatch. Our 12-month warranty covers manufacturing defects and functional failure under normal operating conditions from the date of shipment. It does not cover damage resulting from incorrect installation, overvoltage events, or operation outside the module’s rated specifications.

Q4: Can you supply related SINAMICS S120 components such as line modules, control units, or DRIVE-CLiQ cables?
Yes. NINERMAS maintains inventory of a broad range of SINAMICS S120 components to support complete retrofit projects, including Active Line Modules, Control Units, Sensor Module Cabinet units, and associated accessories. Contact our sales team with your full bill of materials for availability and lead time confirmation.

Product Series

SINAMICS

Country of Origin

DE

Catalog Continuation

More Siemens modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.