Original Industrial Spare Part

Siemens 3RW4900-0KC00 PROFIBUS DP Module for SIRIUS 3RW44 — New & Original

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: 3RW4900-0KC00 PLC & Industrial Automation Modules Siemens

RFQ Ready

Request pricing & availability

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

Siemens 3RW4900-0KC00 | Reliable Automation Component for SIRIUS 3RW44 Fieldbus Integration

Field Application & Operational Analysis

From a Site Reliability Engineer’s perspective, the Siemens 3RW4900-0KC00 represents a mission-critical automation component that directly governs system availability in motor-driven process lines. The 3RW4900-0KC00 bridges SIRIUS 3RW44 soft starters (35A 710A range) to PROFIBUS DP V1 networks, enabling real-time cyclic data exchange tart/stop commands, thermal status, phase fault codes ithout additional hardwired I/O infrastructure. Eliminating analog signal runs reduces wiring complexity and measurably shortens mean-time-to-repair (MTTR) during unplanned outages.

Deployed across chemical dosing skids, compressor stations, and conveyor drive systems, the 3RW4900-0KC00 demonstrates consistent performance under ambient temperatures ranging from -25 °C to +60 °C and IP20 enclosure conditions. Installation demands attention to PROFIBUS address assignment via onboard rotary switches and correct termination at network endpoints; improper termination remains the leading cause of intermittent communication faults in fieldbus topologies. Commissioning engineers should verify GSD file revision compatibility with the master controller prior to first power-on.

As production lines age and OEM support windows close, maintaining a certified spare of the 3RW4900-0KC00 in the site storeroom is a non-negotiable element of any robust spare-parts strategy. EOL and legacy module availability is finite; securing verified original stock now prevents costly production stoppages when the primary unit eventually requires replacement.

Key Operational Features

PROFIBUS DP V1 Compliance — Full cyclic and acyclic communication support for advanced diagnostics and parameter write-back via Class 2 master.
Auto Baud-Rate Detection — Seamlessly adapts from 9.6 kbit/s to 12 Mbit/s; no manual speed configuration required during network commissioning.
Redundancy-Ready Architecture — Compatible with DP/DP coupler configurations for high-availability, dual-ring PROFIBUS topologies in mission-critical applications.
Plug-In Form Factor — Direct insertion into the SIRIUS 3RW44 communication slot; zero additional mounting hardware, zero firmware update dependency.
Extended Diagnostic Transparency — Exposes per-phase motor current, thermal overload margin, phase-sequence errors, and operational hour counters to the SCADA layer.
Seamless Integration — GSD file available via Siemens Industry Online Support; compatible with STEP 7, TIA Portal, and third-party PROFIBUS masters for rapid system integration.

Maintenance & Performance Benchmarks

The 3RW4900-0KC00 is engineered to operate within distributed industrial network architectures ranging from small standalone cells (fewer than 10 nodes) to plant-wide PROFIBUS segments carrying 125+ devices. Its auto baud-rate detection eliminates the manual speed-matching step that historically caused commissioning delays in multi-vendor environments.

Preventive maintenance protocols should include periodic verification of the 9-pin D-sub connector seating and inspection of the integrated terminating resistor switch position whenever the soft starter is removed for servicing. Diagnostic data accessible via acyclic PROFIBUS communication articularly thermal overload accumulator values an be trended in historian systems to support predictive maintenance scheduling, reducing unplanned motor trips by identifying thermal stress patterns before they escalate to fault conditions. This level of process optimization is only achievable through a properly configured fieldbus interface such as the 3RW4900-0KC00.

Comprehensive Data Sheet

Attribute Technical Data
Part Number 3RW4900-0KC00
Manufacturer Siemens
Product Family SIRIUS 3RW44 Accessories
Communication Protocol PROFIBUS DP V1
Compatible Soft Starters SIRIUS 3RW44 series (35A — 710A)
Baud Rate Range 9.6 kbit/s — 12 Mbit/s (auto-detection)
Connector Type 9-pin D-sub with integrated terminating resistor
Operating Temperature -25 °C to +60 °C
Protection Rating IP20
Mounting Method Direct plug-in to soft starter communication slot
Weight 0.149 kg
Country of Origin Germany
Condition New & Original, Factory Packaging
Warranty 1 Year

Professional Logistics & Sourcing Excellence

Every unit of the 3RW4900-0KC00 dispatched from our facility ships in original Siemens factory packaging, complete with manufacturer labels and traceability documentation ritical for quality audits and warranty validation. Where stock is confirmed available, same-day dispatch is offered for orders placed before the daily cut-off, supporting urgent maintenance scenarios where production downtime costs are measured in thousands of dollars per hour.

Our global supply network specifically addresses EOL and legacy module demand. As Siemens periodically transitions product lines, sourcing verified original stock of automation components like the 3RW4900-0KC00 becomes progressively more challenging through standard distribution channels. We maintain strategic inventory buffers to serve customers across North America, Europe, Southeast Asia, and the Middle East, with worldwide express logistics options ensuring delivery timelines aligned to your maintenance window ot the other way around. Operational excellence in sourcing is as important as operational excellence on the plant floor.

Engineering Support & FAQ

Q1: What is the correct installation sequence for the 3RW4900-0KC00?
A: Power down the SIRIUS 3RW44 soft starter completely before inserting the module into the communication slot. Set the PROFIBUS node address using the onboard rotary switches (valid range: 1-125). Import the corresponding GSD file into your PROFIBUS master configuration tool, assign the slave address, and perform a network scan to confirm recognition. Restore power and verify cyclic data exchange via the master’s diagnostic view.

Q2: Which firmware versions of the SIRIUS 3RW44 are compatible with this module?
A: The 3RW4900-0KC00 is compatible with all production firmware releases of the SIRIUS 3RW44 family. No minimum firmware version constraint applies; however, Siemens recommends running the latest available firmware to access full acyclic diagnostic capabilities. Firmware version can be read via the soft starter’s local display or through the PROFIBUS acyclic channel after module installation.

Q3: Can the module be hot-swapped during plant operation?
A: Hot-swap is not supported. The 3RW4900-0KC00 must be inserted or removed only when the soft starter is de-energized. Attempting insertion under power risks damage to the communication interface and may trigger a PROFIBUS network fault affecting other nodes on the same segment.

Q4: How is the warranty claim process handled?
A: Units exhibiting defects within the 1-year warranty period should be reported to our technical support team with the original order reference and a description of the fault symptom. We coordinate return merchandise authorization (RMA), perform incoming inspection, and dispatch a replacement unit ypically within 3-5 business days of receiving the defective module. Warranty does not cover damage resulting from incorrect installation or overvoltage events.

Q5: Is the module compatible with third-party PROFIBUS masters outside of Siemens ecosystems?
A: Yes. Because the 3RW4900-0KC00 adheres to the open PROFIBUS DP V1 standard, it integrates with any certified PROFIBUS master ncluding those from Rockwell Automation, Schneider Electric, Beckhoff, and others rovided the GSD file is correctly imported and the master supports DP V1 acyclic services for extended diagnostics.

Q6: What data is available through acyclic PROFIBUS communication?
A: Acyclic services expose parameter read/write access to the soft starter’s full dataset: motor current per phase, thermal overload accumulator, phase-sequence status, operational hour counter, fault history log, and configurable protection thresholds. This data set supports both real-time condition monitoring and offline parameter backup workflows within your process optimization framework.

© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667

Product Series

Siemens Simatic S5 & Specialty Modules

Country of Origin

DE

Reviews

There are no reviews yet.

Be the first to review “Siemens 3RW4900-0KC00 PROFIBUS DP Module for SIRIUS 3RW44 — New & Original”

Your email address will not be published. Required fields are marked

Catalog Continuation

More Siemens modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack