Original Industrial Spare Part

PRESYS TH220 Service-Ready Spare Part for Industrial Maintenance

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: C0525 V70-P 0010-40489 V70-P-353-7-HAAZZBB-18 C3422 , 0021-04878 TH220 TH-220 PLC & Industrial Automation Modules PRESYS

RFQ Ready

Pricing by RFQ
  • SKUC0525 V70-P 0010-40489 V70-P-353-7-HAAZZBB-18 C3422 , 0021-04878 TH220 TH-220
  • CategoryPLC & Industrial Automation Modules
  • BrandPRESYS
  • SupportAvailability, lead time, condition, and shipping coordination

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

PRESYS TH220 Service-Ready Spare Part for Industrial Maintenance

The PRESYS TH-220 is a precision dry-block temperature calibrator widely deployed across industrial process plants, calibration laboratories, and manufacturing facilities requiring traceable temperature verification. As a service-ready original spare part, the TH-220 supports rapid replacement in environments where calibration downtime directly impacts production throughput, regulatory compliance, and quality assurance continuity. Whether you are managing a scheduled annual calibration cycle, responding to an unplanned instrument failure, or building a strategic spare parts inventory for your metrology department, the PRESYS TH-220 delivers the reliability and traceability that maintenance engineers and procurement teams depend on.

Industrial facilities operating PRESYS calibration systems understand that the TH-220 is not an isolated instrument — it functions as a critical node within a broader calibration and measurement infrastructure. Its replacement must be coordinated with a thorough inspection of the surrounding electrical and signal environment to ensure system integrity is fully restored after any maintenance event.

Spare Maintenance Table

Parameter Specification / Detail
Brand PRESYS
Model / SKU TH-220 / TH220
Product Type Dry-Block Temperature Calibrator
Series TH Series (Temperature Calibration)
Temperature Range Ambient to 220°C (typical for TH-220 class)
Accuracy ±0.5°C (typical, subject to calibration certificate)
Power Supply 100–240 VAC, 50/60 Hz
Communication RS-232 / optional RS-485 (model dependent)
Display Digital LCD with setpoint and measured value readout
Compatibility Compatible with TH series probes, PT100 RTD sensors, thermocouples (K, J, T types)
Installation Environment Indoor calibration lab, field calibration, process plant instrument room
Origin Brazil (PRESYS Instrumentos e Sistemas Ltda)
Condition Original spare, pre-shipment tested
Warranty 12 Months from shipment date
Lead Time Subject to stock availability — contact for confirmation
Maintenance Recommendation Annual calibration verification; inspect heating block, probe well, and control board annually

Maintenance Planning for Continuous Operation

When replacing the PRESYS TH-220 in a calibration or process environment, a disciplined maintenance engineer will not limit the inspection to the calibrator unit alone. The TH-220 operates within an interconnected measurement chain, and a failure or degradation in any adjacent component can compromise the accuracy and reliability of the entire calibration process.

Begin by verifying the AC power supply module feeding the TH-220. Unstable mains voltage or a failing power conditioning unit can cause erratic temperature control, setpoint drift, or premature heating element failure. If the facility uses a dedicated isolation transformer or UPS (uninterruptible power supply) for the calibration bench, inspect these units for output voltage stability and battery health before commissioning the replacement TH-220.

Inspect all PT100 RTD reference probes and thermocouple inserts used with the TH-220. Probe well contamination, bent probe shanks, or degraded insulation resistance are common causes of calibration error that are often misattributed to the calibrator itself. Replace any probe showing resistance drift or physical damage alongside the TH-220 unit.

Check the RS-232 or RS-485 communication cable connecting the TH-220 to the data acquisition system or calibration management software. Cable degradation, loose connectors, or ground loop interference can disrupt automated calibration routines. If the facility uses a USB-to-serial converter for legacy connectivity, verify driver compatibility with the current operating system before reconnecting.

For facilities using the TH-220 alongside other PRESYS instruments — such as the PRESYS CS-420 signal calibrator for 4–20 mA loop verification, the PRESYS MCS-13 multifunction calibrator for combined pressure and temperature tasks, or the PRESYS TA-350 temperature probe for reference measurement — ensure that all instruments in the calibration chain are within their own calibration validity period. A replacement TH-220 paired with an out-of-tolerance reference probe will produce non-compliant calibration records.

Review the terminal blocks and wiring harness at the calibration bench. Loose terminations, oxidized contacts, or undersized conductors can introduce measurement uncertainty. Inspect and re-torque all connections as part of the replacement procedure. If the bench uses signal isolators to protect the TH-220 from ground loops in field calibration scenarios, verify isolator output accuracy and replace any unit showing offset errors.

Finally, confirm that the calibration management software (CMMS or standalone calibration database) is updated with the new TH-220 serial number, calibration certificate reference, and next due date. This ensures traceability continuity and prevents compliance gaps during audits.

Site Replacement Workflow

Step 1 — Isolation and Lockout: De-energize the TH-220 and disconnect all probe connections and communication cables. Apply LOTO (Lockout/Tagout) procedures as required by site safety policy.

Step 2 — Documentation: Record the outgoing unit’s serial number, last calibration date, and any fault symptoms observed. Photograph the wiring configuration before disconnection to support accurate reinstallation.

Step 3 — Incoming Inspection: Verify the replacement TH-220 against the purchase order SKU (TH-220 / TH220). Inspect for shipping damage, confirm the calibration certificate is included, and check the warranty start date.

Step 4 — Installation: Connect the replacement unit to the power supply, probe well, and communication interface following the original wiring documentation. Do not power on until all connections are verified.

Step 5 — Functional Verification: Power on the TH-220 and perform a setpoint verification at two or three temperature points within the operating range. Compare readings against a traceable reference thermometer to confirm accuracy within specification.

Step 6 — System Recommission: Reconnect the communication link to the calibration management system. Update the asset register with the new serial number and calibration certificate. Resume normal calibration operations.

This structured replacement workflow minimizes downtime, ensures traceability, and reduces the risk of introducing new measurement errors during the transition from the failed unit to the service-ready replacement.

Spare Parts Support FAQ

Q1: Is the PRESYS TH-220 available as a long-term supply item?
Yes. NINERMAS maintains reserved inventory agreements for end-of-life and hard-to-source PRESYS calibration instruments. Contact our team to discuss long-term supply contracts, minimum order quantities, and lead time commitments for the TH-220 and related TH series components.

Q2: What pre-shipment testing is performed on the TH-220 before dispatch?
Every TH-220 unit shipped by NINERMAS undergoes functional power-on verification, temperature setpoint response testing, and visual inspection for physical integrity. Units are shipped with a calibration certificate or test report confirming pre-shipment performance. The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions from the shipment date.

Q3: How do I confirm compatibility between the replacement TH-220 and my existing probe well and reference probes?
Compatibility verification should be based on probe shank diameter, insertion depth, and sensor type (PT100 RTD or thermocouple type K/J/T). Provide your existing probe model reference and application temperature range when placing your order, and our technical team will confirm fit and function before shipment.

Q4: What is the recommended spare parts inventory strategy for facilities operating multiple PRESYS TH-220 units?
For facilities with three or more TH-220 units in active service, we recommend maintaining at least one service-ready spare on-site to eliminate lead time risk during unplanned failures. For single-unit installations, a pre-negotiated priority supply agreement with NINERMAS ensures rapid dispatch when a replacement is needed, typically within 3–5 business days subject to stock confirmation.

Product Series

Other series

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack