Original Industrial Spare Part

GE 350-E-P5-G5-H-E-E-N-W-SN-D-N | Feeder Retrofit & Modernization Relay

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: 350-E-P5-G5-H-E-E-N-W-SN-D-N PLC & Industrial Automation Modules GE

RFQ Ready

Pricing by RFQ

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

GE 350-E-P5-G5-H-E-E-N-W-SN-D-N — Professional Retrofit & System Upgrade Component

System Modernization & Migration Analysis

As a Retrofit Project Lead overseeing the transition of aging distribution infrastructure, few components deliver as decisive an impact as the GE 350-E-P5-G5-H-E-E-N-W-SN-D-N. This microprocessor-based feeder protection relay serves as the cornerstone of any modernization initiative — replacing worn electromechanical relays or first-generation digital units while dramatically elevating system responsiveness, measurement accuracy, and communication capability. Its role in extending the operational lifespan of existing switchgear panels and substation frameworks cannot be overstated: by slotting into legacy panel cutouts with minimal mechanical modification, it transforms outdated protection schemes into fully IEC 61850-compliant architectures without requiring a full bay replacement.

The GE 350-E-P5-G5-H-E-E-N-W-SN-D-N is engineered with backward compatibility at its core. Whether your existing infrastructure relies on RS485 Modbus RTU, DNP3 serial, or older SCADA polling architectures, this relay bridges the gap between legacy control logic and modern Ethernet-based supervisory systems. Its configurable I/O mapping and flexible CT/VT ratio settings allow engineers to replicate existing protection coordination schemes during migration — preserving institutional knowledge while unlocking next-generation functionality. This dual capability — honoring legacy constraints while enabling forward migration — makes it the preferred choice for phased upgrade programs.

From a total cost of ownership perspective, deploying the GE 350-E-P5-G5-H-E-E-N-W-SN-D-N as a retrofit solution dramatically reduces migration risk. Unlike full panel replacements that require extended outage windows, this relay can be commissioned during scheduled maintenance cycles. The result: lower capital expenditure, reduced downtime exposure, and a measurable reduction in project risk — all while delivering a performance baseline that meets or exceeds modern grid code requirements.

Upgrade Highlights & Compatibility

  • Drop-in Legacy Replacement: Standard panel cutout dimensions ensure compatibility with most existing relay housings — zero structural modification required in the majority of retrofit scenarios.
  • Multi-Protocol Bridge: Simultaneous support for IEC 61850, Modbus TCP/RTU, and DNP3 eliminates protocol conversion middleware, reducing integration complexity and latency.
  • Future-Proof Architecture: Firmware-upgradeable platform ensures the relay evolves with grid standards — protecting your capital investment over a 15-20 year operational horizon.
  • Enhanced Measurement Accuracy: 0.5% metering class performance across voltage, current, power factor, and harmonics — a significant leap over first-generation digital relays.
  • Configurable Logic Engine: Programmable scheme logic replaces hardwired auxiliary relay panels, reducing panel complexity and improving fault traceability.
  • Seamless Integration with SCADA/DCS: Native IEC 61850 GOOSE messaging enables peer-to-peer protection coordination without additional communication hardware.

Modernization Use Cases & Success Stories

DCS-Integrated Substation Upgrade (Utility Sector): A regional utility operating 1980s-era electromechanical overcurrent relays across 47 distribution feeders initiated a phased modernization program. By standardizing on the GE 350-E-P5-G5-H-E-E-N-W-SN-D-N platform, the utility achieved IEC 61850 compliance across all feeders within 18 months — without a single unplanned outage. The relay’s GOOSE-based zone-selective interlocking reduced fault clearance times by 65%, directly lowering arc flash incident energy levels at affected panels.

TSI System Retrofit (Power Generation): A combined-cycle power plant operating legacy turbine supervisory instrumentation (TSI) required feeder protection upgrades to support new auxiliary load shedding schemes. The GE 350-E-P5-G5-H-E-E-N-W-SN-D-N was integrated into the plant’s DCS via Modbus TCP, providing real-time feeder status, metering data, and protection event logs to the central control room. The retrofit eliminated three separate auxiliary relay panels, reducing wiring complexity by 40% and improving diagnostic visibility for plant operators.

Industrial Microgrid Modernization (Manufacturing): A large automotive manufacturing campus transitioned from a radial distribution architecture to a looped microgrid topology. The directional overcurrent elements (67/67N) of the GE 350-E-P5-G5-H-E-E-N-W-SN-D-N enabled selective fault isolation in the new bidirectional power flow environment — a capability entirely absent in the legacy relay fleet. Commissioning was completed during a planned two-week plant shutdown, with zero protection gaps during the transition period.

Migration Technical Data Sheet

Feature / Property Upgrade Value
Full Model Number 350-E-P5-G5-H-E-E-N-W-SN-D-N
Retrofit Compatibility Replaces electromechanical & 1st-gen digital relays; standard panel cutout fit
Communication Protocols IEC 61850 Ed.2, Modbus TCP/RTU, DNP3 (serial & IP)
Protection Functions 50/51, 50N/51N, 67, 67N, 27, 59, 81, 79, 25, 50BF
CT Input Range 1A or 5A nominal — configurable to match legacy CT installations
Auxiliary Supply 100-240V AC/DC — universal input eliminates power supply replacement
Operating Temperature -40°C to +70°C — suitable for outdoor kiosk and harsh industrial environments
Digital I/O 8 configurable inputs / 6 Form-C output relays — maps to legacy wiring schemes
Metering Accuracy Class 0.5 — significant improvement over legacy electromechanical metering
Event Recording 512 time-stamped events @ 1ms resolution — enables post-migration fault analysis
Oscillography High-resolution waveform capture — critical for commissioning verification
Compliance IEC 60255, IEEE C37.90, UL/CSA — meets global retrofit project requirements
Lifecycle Status Active — current production, full OEM support and firmware updates available
Warranty 12 months — covers manufacturing defects and component failures

Supply Chain & Deployment Support

Original & Factory Sealed: Every GE 350-E-P5-G5-H-E-E-N-W-SN-D-N unit supplied through our channel is sourced from authorized distribution networks and arrives in original OEM packaging with full factory traceability documentation. Serial number verification and certificate of conformance are available upon request — essential for regulated utility and nuclear-adjacent retrofit projects.

Expedited Global Logistics: We maintain strategic inventory positions to support urgent retrofit timelines. Express air freight to North America, Europe, Southeast Asia, and the Middle East is available with typical transit times of 3-7 business days. All shipments include commercial invoice, packing list, and country-of-origin documentation to facilitate customs clearance in regulated markets.

Technical Support for Obsolete & Legacy Hardware: Our engineering team specializes in legacy-to-modern migration projects. We provide pre-sales compatibility assessments, CT/VT ratio mapping assistance, and protection coordination review services. For clients decommissioning obsolete relay platforms, we offer side-by-side functional comparison reports to validate that the GE 350-E-P5-G5-H-E-E-N-W-SN-D-N replicates and enhances the protection logic of the unit being replaced.

Retrofit FAQ — Upgrade Guide

Q: Will the GE 350-E-P5-G5-H-E-E-N-W-SN-D-N physically fit my existing relay panel cutout?
A: The 350 series uses a standard 4U panel-mount form factor compatible with most IEC and ANSI relay panel cutout dimensions. In the majority of retrofit scenarios, no panel modification is required. We recommend sharing your existing relay’s dimensional drawing for a pre-installation compatibility check before ordering.

Q: How does the GE 350-E-P5-G5-H-E-E-N-W-SN-D-N communicate with older SCADA systems that only support Modbus RTU over RS485?
A: The relay includes a rear RS485 port with native Modbus RTU support, ensuring direct compatibility with legacy SCADA polling architectures. No protocol converter or gateway is required. As your SCADA infrastructure evolves, the same relay can be reconfigured to communicate via Modbus TCP or IEC 61850 over Ethernet — providing a seamless migration path without hardware replacement.

Q: Can the GE 350-E-P5-G5-H-E-E-N-W-SN-D-N replicate the protection scheme of the electromechanical relay it is replacing?
A: Yes. The relay’s configurable protection elements, time-current curve library (including legacy curve shapes such as CO-8, CO-11, and IAC curves), and programmable scheme logic allow engineers to replicate existing coordination schemes with high fidelity. Our technical team can assist with settings translation from legacy relay documentation.

Q: What is the recommended spare parts strategy for a fleet-wide retrofit using the GE 350-E-P5-G5-H-E-E-N-W-SN-D-N?
A: For fleet deployments of 10 or more units, we recommend maintaining a 10-15% hot spare inventory. The relay’s active lifecycle status ensures continued OEM availability, but maintaining on-site spares eliminates lead time risk during emergency replacements. Contact us for volume pricing and consignment stock arrangements.

Q: How long does commissioning typically take for a retrofit installation?
A: A straightforward one-for-one replacement with settings transfer from an existing relay can be completed in 4-8 hours by an experienced protection engineer. Complex schemes involving custom scheme logic, IEC 61850 GOOSE configuration, or integration with new DCS/SCADA systems may require 1-3 days. We provide commissioning checklists and remote technical support to accelerate the process.

Q: Is the GE 350-E-P5-G5-H-E-E-N-W-SN-D-N compatible with GE’s EnerVista software for offline configuration and testing?
A: Yes. Full EnerVista 350 Setup software support is available for offline settings development, relay testing, and firmware management. This allows protection engineers to pre-configure and validate relay settings in the office before deployment — significantly reducing on-site commissioning time and the risk of configuration errors during live system work.

Product Series

GE Replacement Parts & Accessories

Country of Origin

US

Reviews

There are no reviews yet.

Be the first to review “GE 350-E-P5-G5-H-E-E-N-W-SN-D-N | Feeder Retrofit & Modernization Relay”

Your email address will not be published. Required fields are marked

Catalog Continuation

More GE modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack