Original Industrial Spare Part
Foxboro M130F-N4 Magnetic Flow Transmitter (Foxboro) – New & Original in Stock
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUM130F-N4
- CategoryDCS Distributed Control Systems
- BrandInvensys Foxboro
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Foxboro M130F-N4 Magnetic Flow Transmitter (Foxboro) - New & Original in Stock with SKU M130F-N4.
Foxboro M130F-N4 | Reliable Automation Component for Mission-Critical Flow Measurement
Field Application & Operational Analysis
From a Site Reliability Engineer’s perspective, the Foxboro M130F-N4 stands as a cornerstone instrument in sustaining system availability across high-demand process environments. The M130F-N4 delivers continuous, drift-resistant flow data via its 4-20 mA / HART dual-output architecture, enabling seamless integration into DCS and SCADA platforms without compromising operational uptime. In mission-critical applications — from chemical batch reactors to municipal water distribution networks — this transmitter’s ±0.5% reading accuracy directly supports process optimization and regulatory compliance.
Engineered to withstand the rigors of industrial field deployment, the Foxboro M130F-N4 carries an IP66/IP67 and NEMA 4X enclosure rating, making it resilient against moisture ingress, chemical splash, and particulate contamination. Installation teams should note that proper grounding of the flow tube is essential to eliminate electromagnetic interference — a critical step often overlooked during commissioning that can introduce signal noise in high-conductivity slurry applications. Ambient operating range of -25°C to +60°C accommodates both arctic outdoor installations and heated process buildings.
As production lines increasingly depend on legacy I/A Series infrastructure, maintaining a certified spare of the M130F-N4 is a non-negotiable element of any proactive maintenance strategy. End-of-life (EOL) procurement cycles for Foxboro transmitters can extend 8-16 weeks through standard channels; securing original factory stock in advance eliminates this vulnerability and protects against unplanned downtime costs that routinely exceed instrument value by orders of magnitude.
Key Operational Features
High Availability Output: Dual 4-20 mA analog + HART digital protocol for redundant signal paths and remote diagnostics
Seamless System Integration: Native compatibility with Foxboro I/A Series DCS, Schneider EcoStruxure, and third-party SCADA via HART gateway
Zero Moving Parts: Electromagnetic measurement principle eliminates mechanical wear, reducing scheduled maintenance intervals
Broad Media Compatibility: Measures any conductive liquid 5 µS/cm — acids, bases, slurries, and water-based solutions
Hazardous Area Certification: FM, CSA, and ATEX approvals support Class I Div 1/2 and Zone 1/2 installations
Flexible Mounting Architecture: Integral or remote transmitter head configurations adapt to space-constrained or high-vibration locations
Maintenance & Performance Benchmarks
The M130F-N4 is architected to slot into industrial network topologies ranging from small skid-mounted units to enterprise-scale distributed control systems spanning multiple process areas. Its HART 5/6/7 multi-revision support ensures backward compatibility with legacy field communicators (e.g., Emerson 375/475) while remaining forward-compatible with AMS Device Manager and FieldCare asset management platforms.
Calibration intervals for the M130F-N4 in clean-water service typically extend to 24 months under ISO 9001-compliant maintenance programs, significantly reducing technician labor costs versus mechanical flow meters requiring quarterly inspection. In abrasive slurry service, liner inspection at 12-month intervals is recommended to verify electrode integrity. The transmitter’s self-diagnostic register — accessible via HART command 48 — provides real-time status flags for empty-pipe detection, electrode coating, and coil drive faults, enabling condition-based maintenance rather than time-based replacement cycles.
For multi-drop HART networks, the M130F-N4 supports polling addresses 1-15, allowing up to 15 devices on a single twisted-pair segment — a critical capability for system integration in retrofit projects where cable infrastructure expansion is cost-prohibitive.
Comprehensive Data Sheet
| Attribute | Technical Data |
|---|---|
| Full Model Number | M130F-N4 |
| Manufacturer / Brand | Foxboro (Schneider Electric) |
| Product Series | Invensys I/A Series |
| Product Type | Magnetic Flow Transmitter |
| Output Signal | 4-20 mA analog + HART (Rev 5/6/7) |
| Measurement Accuracy | ±0.5% of reading (flow tube dependent) |
| Minimum Conductivity | 5 µS/cm |
| Power Supply | 12-42 VDC (loop-powered) or 110/220 VAC |
| Ambient Operating Temperature | -25°C to +60°C |
| Enclosure Rating | NEMA 4X / IP66 / IP67 |
| Hazardous Area Approvals | FM, CSA, ATEX (IS & XP options) |
| Compatible Flow Tubes | Foxboro 2800 Series, 8000A Series |
| HART Multi-Drop Support | Polling addresses 1-15 |
| Weight (transmitter only) | ~2.0 kg |
| Condition | New & Original Factory Stock |
| Warranty | 1 Year |
Professional Logistics & Sourcing Excellence
Every M130F-N4 unit dispatched from our facility ships in original factory packaging with full documentation — including calibration certificates, EU Declaration of Conformity (where applicable), and manufacturer data sheets. For in-stock units, same-day dispatch is available on orders confirmed before 14:00 CST, with DHL Express, FedEx International Priority, and UPS Worldwide Expedited options covering 220+ countries and territories.
Our global sourcing network specializes in EOL and legacy Foxboro I/A Series automation components — including discontinued transmitter models, obsolete I/O modules, and hard-to-source process instruments. This capability is particularly valuable for facilities operating aging DCS infrastructure where OEM support has been discontinued but process continuity demands original-specification replacements. All units undergo incoming inspection and functional verification prior to shipment.
Engineering Support & FAQ
Q1: What are the recommended installation steps for the M130F-N4 in a remote-mount configuration?
A: Mount the transmitter head within 5 meters of the flow tube using Foxboro-specified shielded cable (3-conductor, 18 AWG minimum). Ground the cable shield at the transmitter end only to prevent ground loops. Verify coil resistance (typically 20-80 Ω) and electrode insulation resistance (>20 MΩ) before energizing. Commission using a HART communicator to set pipe diameter, flow range, and damping parameters.
Q2: Which firmware versions are compatible with the M130F-N4, and how do I verify the installed version?
A: Firmware version is readable via HART command 0 (device identification). The M130F-N4 supports field firmware upgrades through Foxboro’s FoxCom interface. Consult Foxboro PSS 1-1B2 A for firmware compatibility matrices relative to your DCS host version. Contact our technical team for firmware-specific sourcing if a particular revision is required for your control system.
Q3: Can the M130F-N4 be integrated into a non-Foxboro DCS platform?
A: Yes. The 4-20 mA output is universally compatible with any analog input card. For HART integration into third-party systems (e.g., Emerson DeltaV, Honeywell Experion), a HART multiplexer or gateway (such as the Pepperl+Fuchs HiDMux2700) enables full device management without replacing existing I/O infrastructure — a cost-effective system integration pathway.
Q4: What is the warranty claim process for units purchased through your store?
A: Our 1-year warranty covers manufacturing defects and functional failures under normal operating conditions. To initiate a claim, contact sale@ninermas.com with your order number, a description of the fault, and HART diagnostic data (Command 48 output preferred). RMA authorization is typically issued within 24 business hours, with replacement or repair completed within 10 business days of unit receipt.
Q5: Is the M130F-N4 suitable for custody transfer or fiscal metering applications?
A: The M130F-N4 at ±0.5% accuracy meets the requirements of many internal allocation metering applications. For legally traceable custody transfer per OIML R117 or API MPMS Chapter 5, a flow-tube-specific calibration certificate traceable to national standards (NIST, PTB) is required — available upon request for select configurations.
Q6: What is the lead time for non-stock or special configurations?
A: Standard M130F-N4 configurations are maintained in ready stock for immediate dispatch. Special configurations (e.g., specific liner materials, hazardous area certifications, or remote cable lengths) may require 2-4 weeks sourcing lead time. Contact our procurement team with your full specification for a confirmed availability timeline.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667
| Product Series | I/A Series FBM |
|---|---|
| Country of Origin | US |
Catalog Continuation
Likely Foxboro I/A platform matches.
These parts are closer to the same platform family signaled by the current SKU and title, so buyers can validate continuity before sending a final RFQ.
Catalog Continuation
More Invensys Foxboro modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within DCS Distributed Control Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
Reviews
There are no reviews yet.