Original Industrial Spare Part

Det-Tronics X3301A4M13T2 Multispectrum Infrared Flame Detector – New & Original

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: X3301A4M13T2 SIS Safety & Redundancy Systems Det-Tronics

RFQ Ready

Request pricing & availability

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

Det-Tronics X3301A4M13T2 | Reliable Automation Component for Mission-Critical Fire Detection

Field Application & Operational Analysis

As a Site Reliability Engineer overseeing continuous process operations, few components carry as much weight as a flame detector positioned at the first line of defense. The Det-Tronics X3301A4M13T2 is engineered to maximize system availability in hydrocarbon-rich environments — from offshore platforms to onshore petrochemical complexes. Its triple-wavelength infrared sensing architecture enables the X3301A4M13T2 to distinguish genuine flame signatures from false-positive sources such as solar glare, arc welding, and hot process surfaces, ensuring that safety interlocks are triggered only when operationally justified. This precision directly reduces unplanned shutdowns and preserves production continuity — a core metric in any Operational Excellence program.

Durability under adversarial conditions is non-negotiable in mission-critical automation. The X3301A4M13T2 is housed in 316 stainless steel rated IP66/67, tolerating ambient temperatures from -55 °C to +75 °C and sustained exposure to salt spray, vibration, and corrosive atmospheres. During installation, engineers should ensure unobstructed line-of-sight to the protected hazard zone, mount at 10-30° below horizontal for optimal ground-level fire coverage, and verify conduit sealing integrity before energizing. Proper commissioning of this I/O module within the fire-and-gas system architecture is essential to achieving the SIL 2 performance level certified per IEC 61508.

For maintenance planners and procurement teams managing aging infrastructure, stocking the X3301A4M13T2 as a critical spare is a proven strategy for minimizing mean-time-to-repair (MTTR). As an end-of-life and legacy module with global demand, verified original inventory is increasingly scarce — securing a unit in advance is a direct investment in system integration resilience and uninterrupted process optimization.

Key Operational Features

Triple-IR Multispectrum Sensing — Analyzes three distinct infrared spectral bands for high-confidence hydrocarbon flame discrimination
SIL 2 Certified (IEC 61508) — Validated for deployment in safety-instrumented systems requiring high availability
Dual Output Architecture (T2) — 4-20 mA analog loop + dual relay contacts for seamless integration with DCS, ESD, and suppression systems
Wide 90° Field of View — Broad area coverage reduces detector count and simplifies system integration
Redundancy-Ready Design — Supports voting logic configurations (1oo2, 2oo3) for high-availability safety architectures
Continuous Self-Diagnostics — Onboard health monitoring alerts operators to optical degradation or signal anomalies before failure occurs
ATEX / IECEx Zone 1 Rated — Approved for Class I, Div 1, Groups B, C, D hazardous area classifications

Maintenance & Performance Benchmarks

The X3301A4M13T2 is designed to integrate into industrial network architectures of all scales — from standalone safety panels in small terminals to enterprise-wide fire-and-gas management systems spanning hundreds of nodes. When networked via Det-Tronics Eagle Quantum Premier (EQP) controllers, up to 127 detectors can be monitored per loop, enabling centralized event logging, remote diagnostics, and coordinated alarm management without additional field wiring infrastructure.

Recommended maintenance intervals align with NFPA 72 and IEC 61511 guidelines: quarterly optical window inspection and cleaning, semi-annual functional response testing using a calibrated test flame source, and annual review of relay output continuity and 4-20 mA loop calibration. The detector’s built-in diagnostic channel continuously reports sensor status to the host controller, enabling condition-based maintenance scheduling and reducing unnecessary preventive interventions — a key driver of process optimization in lean maintenance environments.

Comprehensive Data Sheet

Attribute Technical Data
Full Model Number X3301A4M13T2
Manufacturer Det-Tronics (Detector Electronics Corporation)
Detection Technology Triple Infrared (3IR) Multispectrum
Detection Range Up to 65 m (213 ft) for 1 ft² gasoline pan fire
Response Time <3 seconds (typical)
Field of View 90° cone
Operating Temperature -55 °C to +75 °C (-67 °F to +167 °F)
Power Supply 18-32 VDC
Output Signals 4-20 mA analog + dual relay contacts
Housing Material 316 Stainless Steel
Ingress Protection IP66 / IP67
Hazardous Area Rating Class I, Div 1, Groups B, C, D; ATEX/IECEx Zone 1
Safety Integrity Level SIL 2 per IEC 61508
Mounting Thread 1-inch NPT
Weight Approx. 1 kg
Warranty 1 Year

Professional Logistics & Sourcing Excellence

Every unit of the X3301A4M13T2 dispatched from our facility is sourced directly from authorized distribution channels and ships in original factory packaging with full traceability documentation. For in-stock orders, same-day dispatch is available upon order confirmation before the daily cut-off time — a critical advantage when production lines are at risk.

We maintain a dedicated global supply network for EOL (End-of-Life) and legacy automation components, ensuring that facilities running older fire-and-gas architectures can source verified original parts without compromising system integrity. All units undergo pre-shipment inspection, and export documentation (including country of origin certificates and commercial invoices) is prepared to facilitate smooth customs clearance for worldwide express logistics to any destination.

Engineering Support & FAQ

Q1: What are the recommended installation steps for the X3301A4M13T2?
Mount the detector using the 1-inch NPT thread fitting on a rigid structure with clear line-of-sight to the hazard zone. Orient 10-30° below horizontal for ground-level fire coverage. Connect the 4-20 mA loop and relay wiring per the terminal diagram in the installation manual. Seal all conduit entries with approved compound before powering up. Perform a functional test using a calibrated test flame source prior to commissioning.

Q2: Which firmware versions are compatible with Eagle Quantum Premier controllers?
The X3301A4M13T2 is compatible with EQP controller firmware versions 3.x and above. For legacy EQP systems running firmware 2.x, a controller firmware upgrade is recommended before integrating this detector to ensure full diagnostic data exchange and alarm management functionality.

Q3: How is the 1-year warranty processed?
Warranty claims are initiated by contacting our technical support team with the unit serial number, purchase documentation, and a description of the observed fault. Defective units are evaluated within 5 business days of receipt. Verified warranty cases result in direct replacement with an equivalent new or factory-reconditioned unit, with return freight covered.

Q4: Can the X3301A4M13T2 be used in a 2oo3 voting configuration for high-availability systems?
Yes. The dual relay output of the T2 variant supports voting logic architectures. When integrated with a compatible safety PLC or EQP controller, three detectors can be configured in a 2-out-of-3 voting arrangement, significantly reducing both spurious trip rates and the probability of dangerous undetected failure — meeting the redundancy requirements of high-availability safety systems.

Q5: Is the detector suitable for hydrogen fire detection?
The X3301A4M13T2 is optimized for hydrocarbon flame detection. Hydrogen fires emit minimal infrared radiation in the spectral bands monitored by this detector. For hydrogen applications, a UV/IR combination detector is the appropriate selection. Contact our engineering team for application-specific guidance.

Q6: What is the lead time for out-of-stock orders?
For units not immediately available from stock, our global sourcing network typically fulfills orders within 3-10 business days depending on origin location. Expedited sourcing is available for urgent production-critical requirements — contact us directly with your timeline and we will confirm availability and dispatch schedule.

© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667

Product Series

Other Legacy / Discontinued Modules

Country of Origin

US

Reviews

There are no reviews yet.

Be the first to review “Det-Tronics X3301A4M13T2 Multispectrum Infrared Flame Detector – New & Original”

Your email address will not be published. Required fields are marked

Catalog Continuation

Nearby part numbers around X3301A4M.

Use this lane when the buyer is comparing adjacent model numbers, revision-near items, or closely related spare variants within the same brand family.

Open this lane

Catalog Continuation

Alternative parts within SIS Safety & Redundancy Systems.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack