Original Industrial Spare Part
ABB AS00800-10 Safety-Reliable SCOM for Critical Control Sites
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUAS00800-10, SCOM-0800 0190-41127 0021-39792 6SL3130-6AE15-0AB0
- CategorySIS Safety & Redundancy Systems
- BrandABB
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: ABB AS00800-10 Safety-Reliable SCOM for Critical Control Sites with SKU AS00800-10, SCOM-0800 0190-41127 0021-39792 6SL3130-6AE15-0AB0.
ABB AS00800-10 Safety-Reliable SCOM for Critical Control Sites
The ABB AS00800-10 is a ruggedized Serial Communication (SCOM) module in CompactPCI (CPCI) form factor, engineered for deployment within ABB Bailey INFI 90 and Symphony Plus distributed control system (DCS) architectures. Designed to sustain uninterrupted serial data exchange across safety-critical control loops, this module delivers deterministic communication performance in environments characterized by high electromagnetic interference (EMI), thermal cycling, mechanical vibration, and process-critical uptime requirements. For facilities operating continuous production lines, chemical reactors, power generation units, or hazardous area control cabinets, the AS00800-10 represents a proven, field-validated communication backbone that directly reduces the risk of control interruption, signal drift, and unplanned process shutdown.
Safety Reliability Table
| Parameter | Specification / Detail |
|---|---|
| Part Number | AS00800-10 |
| Compatible Aliases / Cross-References | SCOM-0800, 0190-41127, 0021-39792 |
| Module Type | Ruggedized Serial Communication (SCOM) Module |
| Form Factor | CompactPCI (CPCI) |
| Platform Compatibility | ABB Bailey INFI 90, Symphony Plus DCS |
| Communication Interface | Serial (RS-232 / RS-485 configurable) |
| EMI / RFI Protection | Ruggedized design with shielded enclosure for high-noise industrial environments |
| Operating Temperature | 0°C to +60°C (standard industrial range) |
| Humidity Tolerance | 5% to 95% RH, non-condensing |
| Vibration Resistance | Compliant with IEC 60068-2-6 industrial vibration standards |
| Mounting | CPCI backplane slot, compatible with standard INFI 90 control cabinets |
| Safety Relevance | Supports critical interlock communication loops and safety-instrumented system (SIS) data paths |
| Warranty | 12 Months — NINERMAS full replacement warranty |
| Pre-Shipment Testing | Full functional verification performed before dispatch |
| Inventory Status | In stock — long-term supply commitment available |
| Condition | Refurbished / Tested, equivalent to OEM performance standard |
Control Cabinet Risk Reduction Strategy
In safety-critical control cabinets, communication integrity is not a convenience — it is a process protection requirement. The AS00800-10 SCOM module anchors the serial data layer within INFI 90 control nodes, ensuring that field device signals, interlock commands, and process variable updates are transmitted without latency or corruption. When deployed alongside the IMASI03 analog signal input module, the AS00800-10 ensures that analog process values are accurately relayed to the DCS controller without signal drift caused by ground loops or EMI coupling — a common failure mode in petrochemical and power plant environments.
In high-density I/O cabinets, the IMDSO14 digital output module depends on reliable communication from the SCOM layer to execute actuator commands with millisecond-level precision. Any communication anomaly between the SCOM module and the controller backplane can result in delayed or missed output signals — a risk that the AS00800-10’s ruggedized design directly mitigates through its shielded CPCI interface and deterministic serial protocol handling.
Power quality is equally critical in continuous process environments. The IEPAS02 power supply module, commonly installed in the same INFI 90 cabinet, provides regulated DC power to the communication and I/O modules. Voltage transients, surge events, and power interruptions are among the leading causes of communication module faults. The AS00800-10 is rated to tolerate the power envelope delivered by the IEPAS02, and its internal protection circuitry absorbs minor surge events without requiring a module reset — preserving communication continuity during grid disturbances.
For facilities that rely on the INNIS21 node interface module to bridge multiple INFI 90 control nodes, the AS00800-10 provides the serial communication path that enables cross-node data sharing. Loss of this communication link can isolate a control node from the broader DCS network, triggering safety shutdowns or forcing operators into manual control — an unacceptable condition in unmanned or hazardous area installations. The IMFEC12 fieldbus expansion module similarly depends on a stable SCOM layer to maintain fieldbus segment integrity across PROFIBUS or HART-connected field instruments.
In safety instrumented systems (SIS) integrated with the INFI 90 platform, the IMMPI01 multi-port interface module handles communication between the safety logic solver and the process control network. The AS00800-10 supports this architecture by maintaining the serial data path that carries diagnostic and status information between the SIS and the DCS operator station. Interruption of this path can mask safety system faults from the control room, increasing the risk of undetected dangerous failures. The INTKM01 token ring communication module, used in larger INFI 90 installations, also relies on the SCOM layer for inter-module synchronization — making the AS00800-10 a foundational component in multi-node safety architectures.
For installations where the IMCIS02 communication interface module manages Modbus or proprietary serial protocol bridges, the AS00800-10 provides the physical serial layer that sustains these protocol conversions under load. In environments with high dust ingress, moisture, or chemical vapor — such as water treatment facilities, mining operations, or offshore platforms — the ruggedized construction of the AS00800-10 ensures that the communication layer remains operational where standard commercial-grade modules would degrade or fail. The NTCL01 termination module, installed at the cable interface point, completes the signal chain by providing proper line termination — reducing reflections and signal integrity issues that could otherwise cause communication errors at the AS00800-10 receiver input.
Critical Industrial Safety Applications
Petrochemical and Refinery Plants: In continuous hydrocarbon processing, the AS00800-10 sustains serial communication between DCS controllers and field-mounted analyzers, flow computers, and emergency shutdown (ESD) system interfaces. Communication failures in these environments can trigger unplanned flare events, process upsets, or safety system activations. The module’s EMI-hardened design is particularly valuable in areas adjacent to variable frequency drives (VFDs), large motor control centers (MCCs), and high-voltage switchgear — all of which generate significant electromagnetic noise that can corrupt serial data on standard communication modules.
Power Generation and Utilities: Thermal power stations, combined-cycle gas turbine (CCGT) plants, and hydroelectric facilities rely on INFI 90 DCS platforms for turbine control, boiler management, and grid synchronization. The AS00800-10 maintains the serial communication paths that carry turbine speed signals, generator excitation data, and protection relay status to the control room. In these applications, communication latency or data corruption can result in turbine trips, grid instability, or protection system misoperation — consequences that carry both safety and financial implications.
Mining and Mineral Processing: Conveyor systems, crusher controls, and flotation cell automation in mining operations demand communication modules that can withstand extreme vibration, dust, and temperature variation. The AS00800-10’s ruggedized CPCI construction makes it suitable for deployment in mine site control rooms and remote I/O cabinets where standard modules frequently fail due to environmental stress. Its compatibility with the INFI 90 platform allows direct replacement of failed communication modules without requiring DCS reconfiguration or software changes.
Water and Wastewater Treatment: Municipal and industrial water treatment facilities use INFI 90 systems to manage pump sequencing, chemical dosing, and effluent monitoring. The AS00800-10 supports serial communication with flow meters, pH analyzers, and SCADA gateways in environments with high humidity and chemical vapor exposure. Reliable communication in these applications is essential for regulatory compliance and public safety.
Metallurgy and Steel Production: Electric arc furnaces, rolling mills, and continuous casting lines generate extreme EMI and thermal loads. The AS00800-10’s shielded design and industrial temperature rating make it a dependable communication module in these demanding environments, where control system reliability directly impacts production yield and worker safety.
Safety and Quality FAQ
Q1: What warranty does NINERMAS provide for the AS00800-10?
All AS00800-10 units supplied by NINERMAS carry a 12-month replacement warranty from the date of shipment. If the module fails under normal operating conditions within the warranty period, NINERMAS will provide a replacement unit at no additional cost. This warranty applies to both the module hardware and its firmware functionality as verified during pre-shipment testing.
Q2: What pre-shipment testing is performed on the AS00800-10?
Every AS00800-10 unit undergoes full functional verification before dispatch. Testing includes power-on self-test (POST) validation, serial port communication verification at rated baud rates, backplane interface continuity checks, and visual inspection for physical damage or component degradation. Test records are maintained for traceability and are available upon request for quality-critical procurement processes.
Q3: Is the AS00800-10 compatible with both INFI 90 and Symphony Plus DCS platforms?
Yes. The AS00800-10 is designed for use within ABB Bailey INFI 90 control system architectures and is also compatible with Symphony Plus installations that retain INFI 90 hardware infrastructure. Compatibility is determined by the specific node configuration and backplane type. NINERMAS recommends confirming the target slot designation and node type before installation to ensure seamless integration without requiring DCS software modifications.
Q4: Can NINERMAS support long-term supply of the AS00800-10 for ongoing maintenance programs?
Yes. NINERMAS maintains reserved inventory of the AS00800-10 and related INFI 90 communication modules to support long-term spare parts programs for facilities with extended plant lifecycles. Reserved stock commitments are available for customers requiring guaranteed supply over 12–36 month maintenance windows. This service is particularly relevant for plants where the INFI 90 platform is no longer in active production by the OEM, making aftermarket supply the primary source for replacement modules. Contact NINERMAS to discuss reserved inventory arrangements and lead time commitments.
| Product Series | INFI 90 |
|---|---|
| Country of Origin | SE |
Catalog Continuation
More ABB modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: DSQC1000 3HAC042766-001
ABB 3HAC042766-001 Safety-Reliable Robot CPU for Critical Sites
SKU: DSTD131 57160001-HU
ABB DSTD131 57160001-HU Retrofit-Compatible Connection Module
SKU: ZINT-541 3AUA0000065896R
ABB ZINT-541 3AUA0000065896R Retrofit Drive Board for Legacy Systems
SKU: 3BSE018137R1 CI858-1
ABB CI858-1 3BSE018137R1 Service-Ready Spare Part
Catalog Continuation
Alternative parts within SIS Safety & Redundancy Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: IS200BPVCG1BR1
GE IS200BPVCG1BR1 Safety-Reliable Board for Critical Control
SKU: FC-SCNT02 FC-TCNT11 FC-SCNT01 FC-SSWM01 .CC-SDRX01
Honeywell FC-SCNT02 Retrofit-Compatible Safety Controller Node