Original Industrial Spare Part

DOLD BN3081 Retrofit-Compatible Extension Module

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: BN3081 SIS Safety & Redundancy Systems DOLD

RFQ Ready

Pricing by RFQ

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

DOLD BN3081 Retrofit-Compatible Extension Module for Legacy Systems

The DOLD BN3081 is a safety relay extension module engineered for seamless integration into existing automation architectures where legacy safety relay systems require expansion, replacement, or modernization. As industrial facilities face the challenge of maintaining operational continuity while upgrading aging control infrastructure, the BN3081 provides a technically sound, cost-effective path to extend the service life of installed DOLD safety relay platforms without requiring a full system overhaul. Whether you are managing a phased retrofit in a chemical processing plant, upgrading a legacy safety circuit in a press control cabinet, or replacing a discontinued module in a packaging line, the BN3081 delivers the compatibility, reliability, and field-proven performance that maintenance engineers and system integrators demand.

DOLD has long been recognized as a specialist in safety relay technology, and the BN3081 reflects the brand’s commitment to backward compatibility and long-term spare parts availability. The module is designed to interface directly with DOLD’s established safety relay families, including the DOLD BD5988 base unit and the DOLD BH5928 monitoring relay, allowing engineers to expand output channels or add redundant monitoring paths without redesigning the existing wiring harness or modifying the control cabinet layout. This is particularly valuable in facilities where the original panel drawings are no longer available and any wiring change carries significant risk of introducing new faults.

Upgrade Compatibility Table

Parameter Detail
SKU / Part Number BN3081
Brand / Manufacturer DOLD (E. Dold & Söhne KG, Germany)
Module Type Safety Relay Extension Module
Series Compatibility DOLD Safemaster / BD / BH Safety Relay Series
Mounting DIN Rail (35 mm), compatible with standard control cabinet profiles
Supply Voltage 24 V DC / 24–240 V AC (confirm with original system nameplate)
Output Contacts Relay output, safety-rated, suitable for Category 3 / PLd circuits
Interface / Connection Plug-in terminal block; compatible with existing DOLD base unit connectors
Communication Hardwired safety circuit; no fieldbus dependency
Operating Temperature -10°C to +55°C
Protection Rating IP20 (panel-mounted)
Certifications CE, TÜV-assessed safety relay design
Replacement Compatibility Direct replacement for BN3081 and functionally equivalent legacy DOLD extension modules
Commissioning Notes Verify terminal assignment against original wiring diagram; confirm base unit firmware revision if applicable
Warranty 12 Months from shipment date — covers manufacturing defects and functional failure under normal operating conditions

Retrofit Planning for Existing Automation Systems

A successful retrofit using the DOLD BN3081 begins well before the module arrives on site. Experienced system integrators typically start by auditing the existing safety relay cabinet to document the current wiring topology, terminal numbering, and the functional role of each relay channel. In many legacy installations, the BN3081 was originally paired with a DOLD BD5988 base safety relay, which handles the primary monitoring function — dual-channel input monitoring, cross-circuit detection, and timed or instantaneous output switching. The BN3081 extension module adds additional normally-open and normally-closed output contacts, enabling the safety circuit to drive more actuators, contactors, or downstream safety PLCs without duplicating the monitoring logic.

During the retrofit planning phase, engineers must confirm the power supply capacity of the existing 24 V DC rail. In cabinets where a DOLD GY1 power supply unit or a third-party SITOP or Phoenix Contact power supply is installed, the additional current draw of the BN3081 must be factored into the load calculation. If the existing supply is already near capacity, a supplementary power rail or a higher-rated supply should be provisioned before the new module is installed.

Terminal block compatibility is another critical checkpoint. The BN3081 uses a plug-in terminal design that matches the DOLD standard footprint, but engineers should verify that the existing cabinet uses the correct terminal pitch and that the wire cross-sections are within the module’s rated range. In older installations, wiring may have been sized for a previous generation of DOLD modules with different terminal specifications, and adapters or re-termination may be required.

For systems that include a DOLD BH5928 speed and standstill monitoring relay or a DOLD UG6948 guard door monitoring module, the BN3081 extension can be integrated into the same safety loop to provide additional output capacity for interlocking conveyors, robotic cells, or hydraulic press circuits. In these multi-module configurations, the address or channel assignment of the extension module must be confirmed against the original system documentation to avoid output conflicts.

Where the legacy system also includes a Siemens S7-300 CPU or a Schneider Electric Modicon M340 controller reading safety relay status via digital input modules, the retrofit must account for the I/O address mapping in the PLC program. If the BN3081 replaces a module that previously drove a specific DI channel, the new wiring must preserve the same signal path, or the PLC program must be updated to reflect the new terminal assignment. This step is often overlooked and is a common source of commissioning delays.

HMI screens that display safety relay status — whether on a Siemens TP700 Comfort Panel, a Schneider Electric Magelis GTO panel, or a SCADA system — should be reviewed to confirm that the tag names and alarm logic remain valid after the retrofit. In many cases, the HMI reads relay status indirectly through the PLC, so changes at the relay level do not require HMI reprogramming, but this should be verified rather than assumed.

Signal isolators, such as a Phoenix Contact MINI MCR signal conditioner, are sometimes installed between the BN3081 output contacts and the PLC input card to protect against ground loops or voltage level mismatches. These isolators should be retained during the retrofit and their output polarity confirmed against the new module’s contact configuration.

Finally, the installation space within the control cabinet must be measured before ordering. The BN3081 occupies a defined DIN rail width, and in densely populated cabinets, adjacent terminal blocks, cable ducts, or other modules may need to be temporarily relocated to allow safe installation and wiring access.

Downtime Control During System Migration

Minimizing unplanned downtime is the primary concern for any maintenance team undertaking a safety relay retrofit. The DOLD BN3081 is designed to support a structured, low-risk replacement process that preserves the original program logic and maintains field control continuity throughout the migration.

The recommended approach is to pre-wire the BN3081 on a temporary DIN rail section or a spare cabinet panel before the planned maintenance window. All terminal connections can be prepared, labeled, and verified against the original wiring diagram in advance, so that the actual cabinet work during the shutdown is limited to disconnecting the old module, sliding in the new one, and transferring the pre-prepared wiring harness. This approach typically reduces the in-cabinet installation time to under 30 minutes for a single module replacement.

Before the shutdown, the engineering team should capture a full backup of the PLC program, including the safety function block configuration if a safety PLC such as a Siemens S7-1500F or a Rockwell Allen-Bradley GuardLogix is involved. Even though the BN3081 retrofit does not require PLC program changes in most cases, having a verified backup eliminates the risk of data loss if an unexpected fault occurs during the maintenance window.

During commissioning after installation, the safety function must be fully validated before the machine or process is returned to production. This includes manually actuating each safety input — emergency stop buttons, light curtains, guard door switches — and confirming that the BN3081 output contacts open and close correctly in response. The reset behavior of the safety relay must also be verified to confirm that the system requires a deliberate manual reset before outputs re-energize, preventing inadvertent restart after a safety event.

All BN3081 units supplied by NINERMAS undergo pre-shipment functional testing to verify contact continuity, coil response, and output switching under rated load conditions. This testing is documented and available upon request, providing the maintenance team with confidence that the module is fully functional before it enters the cabinet. Combined with the 12-month warranty from the shipment date, this testing protocol significantly reduces the risk of a repeat shutdown caused by a defective replacement part.

Retrofit Support FAQ

Q1: Is the DOLD BN3081 a direct drop-in replacement for the original module?
The BN3081 is designed as a direct replacement within the DOLD safety relay extension family. In most installations, the terminal layout, DIN rail footprint, and output contact configuration are identical to the original module. However, engineers should always verify the terminal assignment against the original wiring diagram before installation, particularly in older cabinets where field modifications may have been made over the years.

Q2: What pre-shipment testing is performed on the BN3081?
Every BN3081 unit supplied by NINERMAS is functionally tested prior to shipment. Testing covers input coil energization, output contact switching, contact resistance measurement, and insulation integrity. A test record is available upon request. Units that do not meet the original DOLD specification are not shipped.

Q3: What is the warranty coverage and how is a claim handled?
The BN3081 carries a 12-month warranty from the date of shipment. The warranty covers manufacturing defects and functional failure under normal operating and storage conditions. To initiate a warranty claim, contact NINERMAS with the order reference, a description of the fault, and the installation date. Replacement units are dispatched promptly to minimize production impact.

Q4: Can NINERMAS support long-term supply of the BN3081 for multi-site retrofit programs?
Yes. NINERMAS maintains stock of the BN3081 and can support blanket order agreements for customers managing multi-site retrofit programs or long-term spare parts commitments. Fixed lead times and reserved stock arrangements are available for customers with ongoing lifecycle management requirements. Contact our team to discuss a supply program tailored to your maintenance schedule.

Product Series

Other series

Catalog Continuation

More DOLD modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within SIS Safety & Redundancy Systems.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack