Original Industrial Spare Part
Olympus XENUS PLUS 800-1953 Safety-Reliable Fluorescence Module
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUW/ U-TV1 X, U-CMAD-2 U-RLA E62706200 E11706200 XENUS PLUS 800-1953
- CategorySIS Safety & Redundancy Systems
- BrandOlympus
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Olympus XENUS PLUS 800-1953 Safety-Reliable Fluorescence Module with SKU W/ U-TV1 X, U-CMAD-2 U-RLA E62706200 E11706200 XENUS PLUS 800-1953.
Olympus XENUS PLUS 800-1953 Safety-Reliable Fluorescence Module for Critical Control Sites
The Olympus XENUS PLUS 800-1953 is a ruggedized fluorescence imaging module engineered for demanding industrial and scientific environments where signal integrity, optical stability, and uninterrupted operation are non-negotiable. Designed to integrate seamlessly with Olympus microscopy and imaging systems, this module supports critical inspection, quality control, and process monitoring workflows across high-stakes industrial sites including semiconductor fabs, pharmaceutical production lines, materials research facilities, and precision manufacturing environments.
At NINERMAS, every unit of the XENUS PLUS 800-1953 is sourced as an original Olympus spare part, pre-shipment tested, and backed by a 12-month warranty. Whether you are replacing a failed module in an active production line or building a strategic spare parts inventory to reduce unplanned downtime risk, this component is available for immediate dispatch with full traceability documentation.
Safety Reliability Table
| Parameter | Specification / Detail |
|---|---|
| Part Number | 800-1953 |
| Compatible SKUs | U-TV1X, U-CMAD-2, U-RLA, E62706200, E11706200 |
| Series | XENUS PLUS |
| Brand | Olympus |
| Module Type | Ruggedized Fluorescence Imaging Module |
| Application | Industrial inspection, fluorescence microscopy, quality control imaging |
| Environmental Protection | Ruggedized construction for vibration, dust, and humidity resistance |
| Signal Stability | Optimized for low signal drift in high-EMI environments |
| Compatibility | Olympus XENUS PLUS series imaging systems |
| Origin | Japan |
| Condition | Original spare part, pre-shipment tested |
| Warranty | 12 Months |
| Lead Time | In stock — ready to ship |
Control Cabinet Risk Reduction Strategy
In critical industrial imaging and inspection systems, the XENUS PLUS 800-1953 fluorescence module does not operate in isolation. Its reliable performance depends on the integrity of the surrounding optical, electrical, and control infrastructure. Maintenance engineers planning a replacement or system audit should simultaneously verify the condition of the U-TV1X camera adapter and U-CMAD-2 C-mount adapter, which interface directly with this module and are subject to mechanical wear in high-cycle inspection environments.
The U-RLA reflected light attachment (E62706200 / E11706200) is a closely associated component in the same optical train. Degradation or misalignment in the U-RLA can cause fluorescence signal attenuation that is often misdiagnosed as a module failure — always inspect this component before condemning the 800-1953 module itself.
On the electrical and control side, engineers should audit the industrial power supply feeding the imaging system. Voltage fluctuations and ripple from inadequate power conditioning are a leading cause of premature fluorescence module failure. Pairing the XENUS PLUS system with a regulated 24VDC DIN-rail power supply and a surge protection device (SPD) at the cabinet entry point significantly extends module service life in environments with unstable grid power.
For systems integrated into automated production lines, the PLC I/O module managing trigger signals to the imaging system should be inspected for contact wear and signal timing drift. A degraded digital output module can introduce trigger jitter that manifests as inconsistent fluorescence capture — a fault that is difficult to isolate without systematic component-level verification. Similarly, the communication interface module (typically Ethernet or serial) connecting the imaging system to the SCADA or MES layer should be checked for firmware currency and connector integrity.
In high-EMI environments such as motor drive cabinets or welding cells, installing a signal isolation barrier between the imaging trigger circuit and the main control bus is strongly recommended. Ferrite cores on signal cables and proper cable segregation between power and signal runs are low-cost measures that protect the 800-1953 module from induced noise that can corrupt fluorescence data or trigger false fault conditions.
Critical Industrial Safety Applications
The Olympus XENUS PLUS 800-1953 fluorescence module is deployed across a broad range of critical industrial and scientific sites where imaging system uptime directly impacts production safety and quality assurance outcomes.
In pharmaceutical manufacturing, fluorescence imaging systems equipped with the XENUS PLUS module are used for cell viability assays, contamination detection, and sterility verification. A module failure in this context can halt batch release testing, creating regulatory compliance risk and production delays with significant financial consequences. Maintaining a spare 800-1953 unit in the site’s critical spare parts inventory is standard practice for GMP-compliant facilities.
In semiconductor fabrication, fluorescence microscopy is used for defect inspection and photolithography verification. The ruggedized construction of the XENUS PLUS 800-1953 makes it suitable for cleanroom environments where vibration from HVAC systems and electrostatic discharge (ESD) are persistent threats to sensitive optical components. Sites running 24/7 fab operations should hold at least one spare module to support rapid swap-out during scheduled maintenance windows.
In materials research and metallurgical analysis, the module supports grain boundary imaging, coating thickness verification, and failure analysis workflows. Metallurgical labs in steel mills, aluminum smelters, and specialty alloy producers rely on continuous imaging system availability to support quality control sign-off on production batches. An unplanned imaging system outage in this context can delay shipment of finished product and trigger customer penalty clauses.
In water treatment and environmental monitoring facilities, fluorescence-based sensors and imaging systems are used for algae detection, turbidity analysis, and effluent quality verification. The XENUS PLUS module’s resistance to humidity and dust ingress makes it well-suited for the challenging environmental conditions typical of water treatment plant instrument rooms.
Safety and Quality FAQ
Q1: What warranty coverage is provided with the Olympus XENUS PLUS 800-1953?
Every unit supplied by NINERMAS carries a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions. Warranty claims are supported with full traceability documentation including pre-shipment test records.
Q2: How is the 800-1953 module tested before shipment?
Each unit undergoes a pre-shipment functional verification process that includes optical path integrity checks, electrical continuity testing, and compatibility verification against the XENUS PLUS system interface specifications. Units that do not meet Olympus OEM performance standards are quarantined and not dispatched.
Q3: Is the XENUS PLUS 800-1953 compatible with all XENUS PLUS series systems?
The 800-1953 module is designed for the Olympus XENUS PLUS series and is compatible with systems using the U-TV1X, U-CMAD-2, and U-RLA interface components. If your system uses a different adapter configuration, contact our technical team at sale@ninermas.com to confirm compatibility before ordering.
Q4: Can NINERMAS support long-term supply of this module?
Yes. NINERMAS maintains reserved inventory agreements and global sourcing networks specifically for end-of-life and hard-to-source Olympus imaging components. We can support scheduled procurement programs, annual blanket orders, and emergency spot supply for the 800-1953 and associated XENUS PLUS series components.
| Product Series | Other series |
|---|
Catalog Continuation
More Olympus modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: OLS-ILW DV525301 AQ8967 PC-I/F, DV525402 AQ8970
Olympus OLS-ILW Service-Ready Spare Part for Industrial Maintenance
Catalog Continuation
Alternative parts within SIS Safety & Redundancy Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 0000104714-07 SIA1600-14FM 400MM (L) X 190MM (W) KXL06050V-N2-S40
Basler 0000104714-07 Safety-Reliable CCD Camera for Critical Sites