Original Industrial Spare Part

GE Multilin UR 8NH CT/VT Module | 8-Channel Current Transformer Input (New & Original)

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: UR 8NH PLC & Industrial Automation Modules GE

RFQ Ready

Request pricing & availability

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

GE Multilin UR 8NH CT/VT Module | Reliable Automation Component for Mission-Critical Protection

Field Application & Operational Analysis

From the perspective of a Site Reliability Engineer managing high-availability power infrastructure, the GE Multilin UR 8NH stands as a cornerstone I/O module within the Universal Relay platform. The UR 8NH delivers eight independent current transformer input channels, enabling simultaneous three-phase current acquisition across multiple feeders — a capability that directly elevates system availability by eliminating single-point measurement gaps in substation and industrial protection schemes. Its role in process optimization is undeniable: precise, real-time current data feeds protection algorithms that minimize fault clearance time and reduce unplanned downtime.

Operational durability is a defining characteristic of the UR 8NH. Rated for continuous operation from -40°C to +85°C, this module withstands the thermal cycling, vibration, and electromagnetic interference inherent to heavy industrial environments. Installation personnel should ensure proper CT secondary shorting procedures are followed prior to module insertion, and verify backplane connector seating to maintain signal integrity. The module’s modular rack-mount form factor simplifies hot-swap maintenance workflows, reducing mean time to repair (MTTR) during critical outages.

As a mission-critical spare component, maintaining at least one UR 8NH in your parts inventory is a recognized best practice for facilities operating GE Multilin Universal Relay platforms. End-of-life (EOL) procurement cycles for legacy protection modules can extend lead times significantly; securing original factory stock now ensures operational continuity and eliminates costly emergency sourcing scenarios.

Key Operational Features

8 Independent CT Input Channels — Full three-phase + neutral current monitoring across multiple protection zones, supporting redundancy in complex substation architectures.
Dual Rated Current Compatibility — Field-selectable 1A or 5A nominal CT secondary inputs via software configuration, ensuring seamless integration with existing CT infrastructure.
High Thermal Withstand Capability — Continuous rating at 4 nominal; 100 nominal for 1 second — engineered for fault current survivability without module degradation.
±0.5% Measurement Accuracy — Precision current acquisition supports high-sensitivity protection functions including differential (87) and restricted earth fault (64) schemes.
Seamless UR Platform Integration — Native backplane communication with GE Multilin CPU modules enables plug-and-play system integration without additional signal conditioning hardware.
IEC 61850 & IEEE C37.90 Compliance — Meets international protection relay standards, facilitating system integration into modern digital substation architectures and SCADA environments.

Maintenance & Performance Benchmarks

The UR 8NH is engineered to adapt across diverse industrial network architectures — from compact distribution substations with single-chassis UR deployments to large-scale transmission facilities utilizing multi-chassis, redundant relay configurations. Its modular design supports incremental I/O expansion: additional CT/VT modules can be added to the same UR chassis without system reconfiguration, enabling scalable protection coverage as network topology evolves.

Performance benchmarks confirm that the module maintains ±0.5% accuracy across its full operating temperature range, with no field calibration required post-installation. Firmware compatibility is managed at the CPU module level; the UR 8NH hardware is transparent to firmware version updates, eliminating module-level firmware dependency risks. Preventive maintenance intervals for the UR platform recommend annual visual inspection of backplane connectors and CT terminal torque verification — both executable without module removal in most chassis configurations.

For facilities managing operational excellence across aging infrastructure, the UR 8NH’s compatibility with legacy UR chassis generations (UR Series C and later) ensures that protection system upgrades can be executed incrementally, preserving capital investment while modernizing measurement accuracy and I/O capacity.

Comprehensive Data Sheet

Attribute Technical Data
Model / Part Number UR 8NH
Manufacturer General Electric (GE) — Multilin Division
Module Function Current Transformer (CT) Input Module
Number of CT Inputs 8 Independent Channels
Nominal Input Current 1A or 5A (software selectable)
Continuous Thermal Rating 4 Nominal Current
Short-Duration Thermal Rating 100 Nominal for 1 Second
Measurement Accuracy ±0.5% of Reading
Frequency Range 50 Hz / 60 Hz
Operating Temperature -40°C to +85°C
Mounting Style Modular Rack-Mount (UR Platform Backplane)
Platform Compatibility GE Multilin Universal Relay (UR) Series
Communication Interface UR Backplane Bus
Regulatory Compliance IEC 61850, IEEE C37.90, UL/CSA Certified
Condition New & Original — Factory Sealed
Warranty 12 Months

Professional Logistics & Sourcing Excellence

Every GE Multilin UR 8NH unit dispatched from our inventory is supplied in original factory packaging, complete with manufacturer documentation and traceability records. We maintain dedicated stock of EOL and legacy GE Multilin modules to support facilities where standard distribution channels no longer carry active inventory — a critical sourcing advantage for aging protection infrastructure.

Orders confirmed before daily cut-off are eligible for same-day dispatch, with global express logistics coverage spanning North America, Europe, the Middle East, Southeast Asia, and beyond. All shipments include full export documentation, commercial invoices, and packing lists to facilitate smooth customs clearance. For time-sensitive production line recovery scenarios, expedited air freight options are available upon request.

Our global supply network for automation components ensures that mission-critical spare parts reach your facility within the shortest possible lead time — minimizing production losses and supporting your operational excellence objectives.

Engineering Support & FAQ

Q: What is the correct installation sequence for the UR 8NH in an energized UR chassis?
A: GE Multilin recommends de-energizing the chassis before module insertion whenever possible. If hot-insertion is required per site procedures, ensure all CT secondary circuits are shorted at the terminal block prior to module removal or insertion to prevent open-circuit CT hazards. Seat the module firmly until the backplane connector engages, then verify module status via the UR platform EnerVista software.

Q: Which UR firmware versions are compatible with the UR 8NH?
A: The UR 8NH is a hardware I/O module; firmware compatibility is governed by the CPU module (e.g., 9AH, 9HH, 9VM series). GE Multilin recommends running UR platform firmware version 7.0x or later for full feature support. Consult the UR Hardware Compatibility Matrix in the GE Grid Solutions documentation portal for version-specific guidance.

Q: Can the UR 8NH be used in a redundant CPU configuration?
A: Yes. The UR 8NH CT input module is fully compatible with UR platform redundant CPU architectures. In redundant configurations, both primary and secondary CPU modules access the shared I/O backplane, ensuring uninterrupted current measurement during CPU switchover events — a key feature for high-availability protection systems.

Q: How do I initiate a warranty claim for a UR 8NH module?
A: Contact our technical support team at sale@ninermas.com with your purchase order reference, module serial number, and a description of the observed fault. Our team will coordinate return merchandise authorization (RMA) processing and arrange replacement dispatch within the 12-month warranty period. Modules must be returned in original packaging with all accessories included.

Q: Is the UR 8NH interchangeable with the UR 8CH module?
A: The UR 8NH and UR 8CH are distinct module variants within the GE Multilin CT/VT module family. While both occupy the same chassis slot form factor, their internal channel configurations and input specifications differ. Always verify the exact part number against your UR platform order code before substitution to ensure protection scheme integrity.

Q: What documentation is included with each UR 8NH shipment?
A: Each unit is supplied with the original GE Multilin product label, factory test certification, and where available, the module instruction manual (GE publication reference: GEK-113000 series). Additional technical documentation including the UR Hardware Manual can be provided upon request.


© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667

Product Series

Multilin

Country of Origin

US

Reviews

There are no reviews yet.

Be the first to review “GE Multilin UR 8NH CT/VT Module | 8-Channel Current Transformer Input (New & Original)”

Your email address will not be published. Required fields are marked

Catalog Continuation

Nearby part numbers around UR8NH.

Use this lane when the buyer is comparing adjacent model numbers, revision-near items, or closely related spare variants within the same brand family.

Open this lane

Catalog Continuation

More GE modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack