Original Industrial Spare Part
Honeywell FC-TSGAS-1624 Field Termination Assembly Module — New & Original
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUFC-TSGAS-1624
- CategoryTSI & Rotating Machinery Monitoring
- BrandHoneywell
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Honeywell FC-TSGAS-1624 Field Termination Assembly Module — New & Original with SKU FC-TSGAS-1624.
Honeywell Field Termination Assembly FC-TSGAS-1624 | Reliable Automation Component
Field Application & Operational Analysis
From the perspective of a Site Reliability Engineer managing mission-critical process environments, the Honeywell FC-TSGAS-1624 represents a cornerstone I/O interface within safety instrumented systems. The FC-TSGAS-1624 directly enhances system availability by providing a robust, galvanically structured termination point for up to 16 analog input channels — minimizing signal degradation and reducing unplanned downtime in high-stakes automation architectures. Its role in process optimization cannot be overstated: clean field signal conditioning at the termination layer is what separates a resilient control loop from a failure-prone one.
Engineered for operational excellence in demanding industrial environments, the FC-TSGAS-1624 is rated for DIN rail mounting on TS32/TS35-7.5 profiles and operates reliably across wide thermal ranges, with fuse derating from 0.5 A at 25°C down to 0.35 A at 70°C ambient — a critical parameter for enclosed cabinet installations. Field wiring accommodates up to 2.5 mm² (AWG 14) on signal terminals and 16 mm² (AWG 8) on power terminals, ensuring compatibility with industrial cable standards without compromising termination integrity.
As production lines age and OEM support windows close, maintaining a certified stock of legacy automation components like the FC-TSGAS-1624 becomes a non-negotiable element of any proactive maintenance strategy. Holding this module as a qualified spare eliminates lead-time risk and protects against extended production stoppages caused by EOL component shortages.
Key Operational Features
16-Channel Analog Input Capacity — Supports up to 16 field input channels with a shared 0 V common reference, enabling high-density signal integration.
Seamless Integration with SAI-1620m — Direct output interface (0-4 V DC, ±0.1% accuracy) ensures lossless data handoff to the upstream safety I/O module.
Redundancy-Ready Architecture — Compatible with Honeywell FSC safety system redundancy configurations for high-availability plant operations.
Multi-Standard Certifications — Approved under CE, T V, UL, CSA, and FM, satisfying global safety compliance requirements for SIL-rated installations.
Low-Power Field Operation — Draws only 3 mA at 24 V DC (without field loads), minimizing power budget impact in distributed I/O architectures.
Schurter-Grade Fuse Protection — Integrated 500 mA / 250 V AC fuse (Schurter PN 0001.2501) provides reliable overcurrent protection at the field termination layer.
Maintenance & Performance Benchmarks
The FC-TSGAS-1624 is designed to slot into both small-scale skid-mounted control panels and large distributed control system (DCS) architectures without modification. Its compact footprint (225 — 70 — 60 mm) allows dense rack population, while the standardized DIN rail interface ensures interchangeability across Honeywell FSC platform generations.
In multi-node industrial network deployments, this module functions as a critical signal conditioning layer between field instrumentation and the safety logic solver. The 500 Ω (±5%) input resistance and 0-25 mA input current range accommodate a broad spectrum of field transmitters, reducing the need for external signal conditioning hardware and simplifying system integration workflows.
Periodic maintenance benchmarks recommend verifying fuse continuity and terminal torque (0.5 Nm signal / 1.2 Nm power) during scheduled shutdowns. Proactive replacement cycles aligned with plant turnaround schedules ensure continuous operational excellence without reactive maintenance disruptions.
Comprehensive Data Sheet
| Attribute | Technical Data |
|---|---|
| Part Number | FC-TSGAS-1624 |
| Manufacturer | Honeywell |
| Product Category | Field Termination Assembly (FTA) |
| Compatible Platform | Honeywell FSC Safety System |
| Number of Input Channels | 16 (with common 0 V) |
| Power Supply | 24 V DC external, 3 mA (no field loads) |
| Input Current Range | 0-25 mA |
| Input Resistance | 500 Ω (±5%) |
| Output Voltage (to SAI-1620m) | 0-4 V DC |
| Output Accuracy | 0.1% |
| Fuse Rating | 500 mA / 250 V AC / 300 V DC |
| Fuse Dimensions | 5 — 20 mm (Schurter 0001.2501) |
| Fuse Derating | 0.5 A @ 25°C — 0.35 A @ 70°C |
| Module Dimensions (L W H) | 225 — 70 — 60 mm (8.86 — 2.76 — 2.36 in) |
| DIN Rail Compatibility | TS32 / TS35-7.5 |
| Rail Length Used | 226 mm (8.90 in) |
| Signal Terminal Wire Size | Max. 2.5 mm² (AWG 14), Strip 7 mm, Torque 0.5 Nm |
| Power Terminal Wire Size | Max. 16 mm² (AWG 8), Strip 7 mm, Torque 1.2 Nm |
| Certifications | CE, T V, UL, CSA, FM |
| General Type Numbers | FS-TSGAS-1624, FC-TSGAS-1624 |
| Condition | New & Original, Factory Packaging |
| Warranty | 1 Year |
Professional Logistics & Sourcing Excellence
Every Honeywell FC-TSGAS-1624 unit dispatched from our inventory is sourced directly from authorized distribution channels and ships in original factory packaging — complete with manufacturer labels, protective inserts, and traceability documentation. This ensures the module arrives in verified, installation-ready condition with no risk of transit damage or counterfeit exposure.
For time-sensitive plant recovery scenarios, same-day dispatch is available on confirmed in-stock units (order cutoff times apply). Our global logistics network covers major industrial hubs across North America, Europe, the Middle East, and Asia-Pacific, with express freight options to minimize downtime windows.
We specialize in global supply for EOL (End-of-Life) and legacy automation components, including discontinued Honeywell FSC platform modules. If your plant relies on aging control infrastructure, our sourcing team maintains active procurement channels to locate and qualify hard-to-find parts — protecting your installed base without forcing a costly system migration.
Engineering Support & FAQ
Q1: What is the correct installation orientation for the FC-TSGAS-1624 on a DIN rail?
The FC-TSGAS-1624 mounts horizontally on TS32 or TS35-7.5 DIN rails. Ensure the rail segment used is at least 226 mm (8.90 in) in length. Secure the module with end stops to prevent lateral movement during vibration events common in industrial environments.
Q2: Which firmware versions of the SAI-1620m are compatible with this FTA?
The FC-TSGAS-1624 is a passive field termination assembly and does not contain firmware. Compatibility is determined by the SAI-1620m module firmware version and the FSC system configuration. Consult your Honeywell FSC system documentation or contact our engineering team for version-specific guidance.
Q3: Can the FC-TSGAS-1624 be used in SIL 2 or SIL 3 rated safety loops?
Yes. The FC-TSGAS-1624 carries T V certification and is designed for integration within Honeywell FSC safety instrumented systems, which support SIL 2 and SIL 3 applications. Always verify the complete safety loop SIL rating with your functional safety engineer.
Q4: How do I initiate a warranty claim if the module fails within the warranty period?
Contact our support team at sale@ninermas.com with your order number, module serial number, and a description of the fault. Our RMA process is initiated within 24 business hours. Replacement units are dispatched upon fault verification, with return freight covered for confirmed warranty cases.
Q5: Is the fuse field-replaceable, and where can I source the correct replacement?
Yes. The 500 mA / 5-20 mm fuse (Schurter PN 0001.2501) is field-replaceable. Replacement fuses are available from Schurter authorized distributors globally. Always de-energize the module before fuse replacement and verify the replacement fuse meets the exact rating to maintain system protection integrity.
Q6: What is the maximum cable length supported for field wiring to the FC-TSGAS-1624?
Maximum cable length depends on cable resistance, field load current, and acceptable voltage drop at the 24 V DC supply. As a general guideline, keep total loop resistance within the 500 Ω input resistance specification. For long cable runs exceeding 500 m, consult your system integrator to assess signal integrity and voltage budget.
—
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667
| Product Series | FSC Safety Manager |
|---|---|
| Country of Origin | NL |
Catalog Continuation
More Honeywell modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within TSI & Rotating Machinery Monitoring.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
Reviews
There are no reviews yet.