Original Industrial Spare Part
GE IC695CPE305-ABAH Retrofit CPU for Legacy PACSystems
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUIC695CPE305-ABAH
- CategoryPLC & Industrial Automation Modules
- BrandGE
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: GE IC695CPE305-ABAH Retrofit CPU for Legacy PACSystems with SKU IC695CPE305-ABAH.
GE IC695CPE305-ABAH Retrofit CPU for Legacy PACSystems: Ruggedized Upgrade for Harsh-Environment Control Systems
The GE IC695CPE305-ABAH is a ruggedized central processing unit designed for the GE PACSystems RX3i platform, engineered to operate reliably in high-vibration, wide-temperature, and electrically noisy industrial environments. As legacy GE Fanuc Series 90-30 and early PACSystems controllers reach end-of-life, the IC695CPE305-ABAH provides a validated retrofit path that preserves existing rack infrastructure, I/O wiring, and program logic while delivering modern processing performance and extended product lifecycle support.
For maintenance engineers and automation integrators managing aging control cabinets, this module eliminates the need for full panel redesigns. The IC695CPE305-ABAH mounts directly into the IC695CHS016 or IC695CHS012 universal backplane, sharing the same rack footprint as earlier CPE300 and CPE302 variants. Power draw is compatible with the IC695PSA040 and IC695PSD040 power supply modules already installed in most RX3i cabinets, avoiding costly power infrastructure upgrades during the changeover.
Before installation, engineers should verify the existing backplane slot assignments and confirm that the IC695ETM001 Ethernet module and any IC695PBM300 PROFIBUS master modules retain their configured node addresses after the CPU swap. Program uploads from the legacy controller should be performed using Machine Edition Logic Developer prior to shutdown, ensuring the ladder logic, function block diagrams, and structured text routines are archived and ready for re-download to the replacement unit.
Upgrade Compatibility Table
| Parameter | IC695CPE305-ABAH | Typical Legacy CPU (CPE302 / Series 90-30) |
|---|---|---|
| Platform | PACSystems RX3i | PACSystems RX3i / Series 90-30 |
| Backplane Compatibility | IC695CHS016, IC695CHS012 | IC695CHS016, IC695CHS012 / IC693CHS391 |
| Power Supply Compatibility | IC695PSA040, IC695PSD040 | IC695PSA040 / IC693PWR321 |
| Operating Temperature | -40°C to +70°C (ruggedized) | 0°C to +60°C (standard) |
| Ethernet Port | Dual RJ-45 embedded | Single or via IC695ETM001 |
| Communication Protocols | SRTP, Modbus TCP, EGD, OPC | SRTP, SNP, Modbus RTU |
| Programming Software | Machine Edition 9.x+ | Machine Edition 7.x / Logicmaster 90 |
| Installation Space | Single slot, standard RX3i form factor | Single slot |
| Replacement Recommendation | Direct drop-in for CPE302, CPE305 standard variants | — |
| Commissioning Focus | IP address, I/O table rebuild, HMI tag remap | — |
| Warranty | 12 Months | — |
Retrofit Planning for Existing Automation Systems
A successful IC695CPE305-ABAH retrofit begins with a thorough audit of the existing control cabinet. Technicians should document all IC694MDL655 discrete input modules, IC694MDL754 discrete output modules, and any IC695ALG600 analog input modules currently installed in the rack, noting their slot positions and configured I/O addresses. This mapping ensures that the replacement CPU can reconstruct the hardware configuration table without address conflicts after the swap.
For systems using PROFIBUS DP networks, the IC695PBM300 master module must retain its GSD file database and slave node configuration. During the CPU replacement window, the PROFIBUS segment should be placed in a safe hold state to prevent uncontrolled output changes on connected drives, valve positioners, and remote I/O stations. Similarly, any IC695CMM002 serial communication modules handling Modbus RTU links to third-party instruments should have their port parameters documented before the changeover.
HMI panels connected via the IC695ETM001 Ethernet module or directly to the CPU’s embedded Ethernet port will require tag database verification after the CPU swap. SCADA systems using OPC DA or OPC UA connections to the PACSystems controller should be tested in offline simulation mode before live cutover. If the plant uses a GE iFIX or Wonderware InTouch HMI, screen tag bindings referencing the old CPU’s IP address must be updated to reflect the new network configuration.
Where the legacy system includes IC693CHS391 Series 90-30 expansion racks connected via IC695LRE001 LAN interface modules, the IC695CPE305-ABAH maintains backward compatibility with the remote I/O scanning architecture, allowing mixed-generation rack configurations to remain operational during a phased migration. This is particularly valuable in large panel installations where replacing all I/O modules simultaneously would extend downtime beyond acceptable production windows.
Signal isolation requirements should also be reviewed during retrofit planning. If the existing installation uses IC693MDL940 relay output modules driving inductive loads, surge suppression across coil terminals should be confirmed before the new CPU begins scanning. Likewise, any IC695ALG728 analog output modules connected to current-loop instruments should be verified for loop power compatibility with the updated I/O configuration.
Downtime Control During System Migration
Minimizing production downtime during a CPU retrofit requires a structured pre-outage preparation sequence. At least 48 hours before the planned maintenance window, the existing program should be uploaded and verified in Machine Edition, with a full hardware configuration export saved to a secure backup location. The IC695CPE305-ABAH should be pre-configured offline — IP address assigned, I/O table loaded, and communication module parameters entered — so that the physical installation and download sequence can be completed within a single shift.
During the outage, the recommended sequence is: power down the rack using the IC695PSA040 supply’s front-panel switch, remove the legacy CPU from slot 0, seat the IC695CPE305-ABAH firmly until the backplane connector is fully engaged, restore power, and confirm the module’s RUN LED illuminates without fault indicators. The program download from Machine Edition typically completes in under three minutes for projects under 1 MB, after which I/O forcing should be used to verify each field device response before releasing the system to automatic control.
For critical processes where even brief interruptions are unacceptable, a parallel rack strategy can be employed: a second IC695CHS012 backplane with the IC695CPE305-ABAH pre-loaded is wired in parallel with the existing rack, allowing a rapid switchover by transferring field wiring terminal blocks rather than reprogramming under pressure. This approach is particularly effective in water treatment, pharmaceutical batch, and continuous chemical process applications where control continuity is a regulatory requirement.
Post-cutover, the first 30 minutes of operation should be monitored with Machine Edition’s online diagnostic view active, confirming that all I/O modules report healthy status, communication modules maintain their link states, and the program scan time remains within the configured watchdog threshold. Any unexpected fault codes should be cross-referenced with the IC695CPE305-ABAH installation manual before the maintenance team leaves the site.
Retrofit Support FAQ
Q1: Is the IC695CPE305-ABAH a direct replacement for the IC695CPE305 standard variant?
Yes. The ABAH suffix designates the ruggedized conformal-coated version of the IC695CPE305. It is electrically and functionally identical to the standard variant and installs in the same backplane slot without program modification. The extended temperature and vibration ratings make it the preferred choice for outdoor enclosures, marine environments, and mobile equipment installations.
Q2: What commissioning steps are required after installing the IC695CPE305-ABAH?
After physical installation, assign the CPU’s IP address via the front-panel Ethernet port using Machine Edition’s Set IP Address utility. Download the archived program and hardware configuration, then perform a controlled I/O checkout by forcing each discrete and analog channel while observing field device responses. Verify that all communication modules — including any IC695ETM001, IC695CMM002, or IC695PBM300 units — have re-established their links before releasing the system to automatic mode.
Q3: Does this unit ship with a warranty, and has it been tested before dispatch?
Every IC695CPE305-ABAH unit supplied by NINERMAS undergoes pre-shipment functional testing, including power-on self-test verification, Ethernet port connectivity confirmation, and program download validation. A 12-month warranty covers manufacturing defects and operational failures under normal industrial use conditions. Warranty claims are processed directly through our technical support team at sale@ninermas.com.
Q4: Can the IC695CPE305-ABAH communicate with legacy Series 90-30 I/O over the same network?
Yes. When paired with an IC695LRE001 LAN interface module, the IC695CPE305-ABAH can scan Series 90-30 remote I/O racks as part of a mixed-generation system architecture. This allows plants to retain existing Series 90-30 I/O investments while upgrading the central processing capability, deferring full I/O replacement to a later phase of the modernization program.
| Product Series | PACSystems |
|---|---|
| Country of Origin | US |
Catalog Continuation
Nearby part numbers around IC695CPE.
Use this lane when the buyer is comparing adjacent model numbers, revision-near items, or closely related spare variants within the same brand family.
SKU: IC695CPE330-ABAF
GE IC695CPE330-ABAF Retrofit-Compatible Ruggedized CPU
SKU: IC695CPE400-ABAB
GE IC695CPE400-ABAB Safety-Reliable CPU for Critical Control Sites
Catalog Continuation
More GE modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: IS200BPVCG1BR1
GE IS200BPVCG1BR1 Safety-Reliable Board for Critical Control
SKU: DS200SDCIG1ABA
GE DS200SDCIG1ABA Retrofit-Compatible Signal Conditioning Module
SKU: IS2020JPDCG1ACB
GE IS2020JPDCG1ACB Safety-Reliable Power Distribution Module