Original Industrial Spare Part
Honeywell FS-CCI-HSE-02 Retrofit-Compatible HSE Cable
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUFS-CCI-HSE-02
- CategorySIS Safety & Redundancy Systems
- BrandHoneywell
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Honeywell FS-CCI-HSE-02 Retrofit-Compatible HSE Cable with SKU FS-CCI-HSE-02.
Honeywell FS-CCI-HSE-02 Retrofit-Compatible HSE Cable for Legacy Safety Manager Systems
The Honeywell FS-CCI-HSE-02 is a High Speed Ethernet (HSE) communication cable designed for use within the Honeywell Safety Manager (SM) platform — one of the most widely deployed Safety Instrumented Systems (SIS) in the process automation industry. As legacy Safety Manager installations age and original cable assemblies reach end-of-life, the FS-CCI-HSE-02 provides a direct, retrofit-compatible replacement that preserves existing network topology, communication integrity, and SIL-rated system performance without requiring controller reprogramming or cabinet redesign.
For maintenance engineers managing aging SIS infrastructure, sourcing a verified FS-CCI-HSE-02 is a critical step in sustaining HSE fieldbus communication between the Safety Manager controller chassis and connected I/O modules, engineering workstations, or peer safety controllers. This cable supports the HSE (High Speed Ethernet) protocol layer used in the Honeywell Safety Manager architecture, enabling deterministic, high-integrity data exchange across the safety network. Replacing a degraded or damaged cable with a genuine FS-CCI-HSE-02 eliminates communication faults, CRC errors, and intermittent link-loss alarms that can trigger spurious shutdowns or compromise SIL loop integrity.
All units supplied by NINERMAS are sourced from verified industrial channels, subject to pre-shipment electrical continuity and connector integrity testing, and covered by a 12-month warranty. Global shipping is available with lead times confirmed at order placement.
Upgrade Compatibility Table
| Parameter | Details |
|---|---|
| Part Number | FS-CCI-HSE-02 |
| Brand | Honeywell |
| Series | Safety Manager (SM) — HSE I/O Bus |
| Cable Type | HSE (High Speed Ethernet) Communication Cable |
| Protocol | HSE Fieldbus / Industrial Ethernet |
| Connector Interface | RJ45 / HSE-compatible industrial termination |
| Compatible Controllers | Honeywell Safety Manager SM, FSC Platform |
| Compatible Modules | FS-IOBUS-CPIO4, FS-SDO-0824, FS-SDI-1624 series I/O |
| Installation Requirement | Verify cable routing, bend radius, and connector seating in cabinet |
| Retrofit Suitability | Direct replacement for degraded or end-of-life HSE cable assemblies |
| Commissioning Note | Confirm link status LED on HSE switch/hub after installation |
| Warranty | 12 Months from shipment date |
| Pre-Shipment Test | Continuity, connector integrity, and insulation check |
| Origin | USA (Honeywell) |
Retrofit Planning for Existing Automation Systems
When replacing the FS-CCI-HSE-02 in an operational Safety Manager installation, the scope of work extends beyond the cable itself. A structured retrofit assessment should cover all components that share the HSE communication segment or depend on its signal integrity.
Begin with the HSE managed switch or hub — typically a Hirschmann or Honeywell-qualified industrial Ethernet switch installed in the SIS cabinet. Verify that switch port configuration, VLAN assignments, and link speed settings are compatible with the replacement cable. If the switch is also aging, consider replacing it alongside the FS-CCI-HSE-02 to avoid a secondary failure shortly after the cable retrofit.
Next, inspect the Safety Manager controller backplane and chassis connectors. The FS-CCI-HSE-02 interfaces with the controller’s HSE port, and any corrosion, bent pins, or mechanical wear on the chassis-side connector will negate the benefit of a new cable. Check the FS-IOBUS-CPIO4 I/O bus coupler module, which relies on the HSE link to communicate process I/O data back to the controller — a degraded cable is often the root cause of intermittent I/O communication faults logged against this module.
Review the power supply modules feeding the Safety Manager chassis, such as the FS-PSU series. Voltage sags or ripple on the 24 VDC rail can cause HSE communication instability that mimics cable faults. Confirm power supply output is within specification before attributing communication errors solely to the cable. Similarly, inspect terminal blocks and field wiring in the cabinet for loose connections that could introduce ground loops or EMI affecting the HSE segment.
For sites running Experion PKS or Safety Builder engineering software, confirm that the HSE network node address and IP configuration of the Safety Manager controller remain unchanged after cable replacement — no software changes should be required for a like-for-like cable swap, but network discovery should be re-validated post-installation. If the site also uses FS-CCI-HSE-01 or other HSE cable variants in the same cabinet, inspect those simultaneously to avoid repeat maintenance visits.
Where the retrofit involves migrating from an older FSC (Fail-Safe Controller) platform to the current Safety Manager architecture, the FS-CCI-HSE-02 plays a key role in establishing the new HSE communication backbone. In such migrations, engineers must also plan for I/O module address reassignment, marshalling cabinet rewiring, and SIL verification testing of all affected safety loops before returning the system to service. Signal isolators and intrinsic safety barriers in the field junction boxes should be inspected as part of the same work order to maximize the value of the planned outage.
Downtime Control During System Migration
Replacing the FS-CCI-HSE-02 in a live Safety Manager environment requires careful outage planning to minimize process disruption. The following workflow is recommended for sites where the Safety Manager is actively monitoring safety-critical loops:
1. Pre-Outage Preparation: Obtain a verified FS-CCI-HSE-02 from stock before scheduling the outage. Confirm cable length, connector type, and routing path in the cabinet. Download and archive the current Safety Manager configuration using Safety Builder to protect program logic. Notify operations and obtain a Management of Change (MOC) permit.
2. Controlled Shutdown Sequence: Place affected safety loops in manual or bypass mode per site procedures. Power down only the HSE communication segment — do not de-energize the entire Safety Manager chassis unless required. Disconnect the degraded FS-CCI-HSE-02 and install the replacement, ensuring correct connector seating and cable routing without sharp bends.
3. Post-Installation Verification: Power up the HSE segment and confirm link status LEDs on both the controller HSE port and the managed switch. Use Safety Builder or the Experion PKS console to verify that all I/O modules — including FS-IOBUS-CPIO4 and associated digital I/O cards — are communicating without faults. Run a communication diagnostic and confirm zero CRC errors over a 15-minute observation window before releasing loops from bypass.
4. Return to Service: Restore all safety loops to automatic mode. Document the replacement in the site maintenance management system (CMMS) and update the spare parts inventory. Schedule the next inspection interval based on the cable’s operating environment — high-vibration or high-humidity locations warrant shorter re-inspection cycles.
By following this structured approach, most FS-CCI-HSE-02 replacements can be completed within a 2–4 hour planned outage window, minimizing production impact while maintaining SIS integrity.
Retrofit Support FAQ
Q1: Is the FS-CCI-HSE-02 a direct replacement for all HSE cable variants used in the Safety Manager platform?
The FS-CCI-HSE-02 is the standard HSE communication cable for the Honeywell Safety Manager I/O bus architecture. Confirm the cable length and connector specification against your cabinet layout before ordering. For installations using the FS-CCI-HSE-01 or other length variants, contact NINERMAS to confirm the correct part number for your application.
Q2: Will replacing the FS-CCI-HSE-02 require any changes to the Safety Manager program or I/O configuration?
A like-for-like cable replacement does not require program changes. The HSE network topology, node addresses, and I/O module assignments remain unchanged. However, post-installation network validation using Safety Builder is recommended to confirm all modules are communicating correctly before releasing safety loops from bypass.
Q3: What pre-shipment testing is performed on the FS-CCI-HSE-02?
Each unit undergoes electrical continuity testing across all conductors, connector integrity inspection, and insulation resistance verification before shipment. Units that do not meet specification are rejected. A 12-month warranty covers all supplied cables against manufacturing defects and premature failure under normal operating conditions.
Q4: Can NINERMAS supply the FS-CCI-HSE-02 for long-term maintenance contracts or annual inspection programs?
Yes. NINERMAS maintains stock of the FS-CCI-HSE-02 and can support blanket purchase orders, scheduled annual deliveries, and emergency expedite requests. Long-term supply agreements are available for sites with multiple Safety Manager installations or multi-year maintenance programs. Contact sale@ninermas.com to discuss inventory reservation and lead time commitments.
| Product Series | Safety Manager |
|---|---|
| Country of Origin | US |
Catalog Continuation
More Honeywell modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
Catalog Continuation
Alternative parts within SIS Safety & Redundancy Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: MINI-PS/12-24DC/5-15DC/2 2320018
Phoenix Contact MINI-PS/12-24DC/5-15DC/2 2320018 DC Power Supply