Original Industrial Spare Part
Siemens 3RV6011-1BA15 Service-Ready Spare Part for Industrial Maintenance
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU3RV6011-1BA15
- CategoryPLC & Industrial Automation Modules
- BrandSiemens
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Siemens 3RV6011-1BA15 Service-Ready Spare Part for Industrial Maintenance with SKU 3RV6011-1BA15.
Siemens 3RV6011-1BA15 Service-Ready Spare Part for Industrial Maintenance
The Siemens 3RV6011-1BA15 is a SIRIUS series motor starter protector (circuit breaker) engineered for reliable overcurrent and short-circuit protection in industrial motor control applications. As a direct-replacement spare part, the 3RV6011-1BA15 is stocked and tested to support rapid site restoration, minimizing unplanned downtime in manufacturing lines, process plants, and automated control systems. With a rated current range of 1.4–2.0 A and a compact S00 frame size, this device integrates seamlessly into existing SIRIUS motor starter combinations, control cabinets, and busbar systems without requiring panel redesign or rewiring.
NINERMAS maintains ready inventory of the 3RV6011-1BA15 to support emergency replacement, annual maintenance shutdowns, and long-term spare parts programs. Every unit is inspected and function-tested prior to shipment, backed by a 12-month warranty covering manufacturing defects and operational failures under normal service conditions.
Spare Maintenance Table
| Parameter | Specification |
|---|---|
| Part Number / SKU | 3RV6011-1BA15 |
| Brand | Siemens |
| Series | SIRIUS 3RV6 |
| Product Type | Motor Starter Protector / Circuit Breaker |
| Frame Size | S00 |
| Rated Current (Ir) | 1.4 – 2.0 A |
| Short-Circuit Breaking Capacity (Icu) | 100 kA @ 400 V AC |
| Rated Voltage | Up to 690 V AC |
| Poles | 3-pole |
| Trip Class | Class 10 |
| Mounting | DIN rail (35 mm) / screw mounting |
| Degree of Protection | IP20 (built-in), IP65 with enclosure |
| Ambient Temperature | -25 °C to +60 °C |
| Compatibility | SIRIUS 3RT, 3RH contactors; 3RV6 busbar systems; 3RA6 compact starters |
| Standards | IEC/EN 60947-2, UL 489, CSA C22.2 |
| Origin | Germany (DE) |
| Warranty | 12 Months (NINERMAS) |
| Availability | In Stock — Ready to Ship |
Maintenance Planning for Continuous Operation
When replacing the 3RV6011-1BA15 in a motor control center or control cabinet, a disciplined maintenance approach requires inspecting the entire motor starter assembly and associated circuit components. The 3RV6011-1BA15 operates as part of a coordinated protection chain — its replacement is the ideal moment to audit adjacent components for wear, thermal stress, or impending failure.
Begin with the Siemens 3RT6016 or 3RT6017 contactor paired with this protector in a SIRIUS combination starter. Contactor coil insulation and contact wear should be verified whenever the motor protector trips or is replaced. Next, inspect the 3RV6 busbar system or individual power terminals for signs of overheating, discoloration, or loose connections — thermal cycling in high-cycle applications accelerates terminal fatigue.
The 24 VDC or 230 VAC control power supply feeding the contactor coil circuit should be load-tested; a degraded SITOP PSU100S or equivalent DIN-rail power supply can cause erratic contactor engagement and nuisance tripping of the motor protector. Simultaneously, verify the auxiliary contact block (e.g., 3RV6901-1D) mounted on the 3RV6011-1BA15 for correct feedback signaling to the PLC or safety relay.
For systems integrated with a Siemens S7-300 or S7-1200 PLC, confirm that the digital input module (e.g., SM 321 or DI 16x24VDC) correctly reads the motor protector’s trip status. A faulty I/O channel can mask a real fault condition, delaying corrective action. If the motor circuit feeds a PROFIBUS DP or PROFINET network node, inspect the communication module and cable shielding — ground loops introduced during maintenance can corrupt fieldbus signals.
Terminal blocks (e.g., Siemens 8WH or Phoenix Contact UK series) adjacent to the motor starter should be torque-checked to manufacturer specification. Loose terminals are a leading cause of intermittent faults that are difficult to diagnose under load. Where signal isolation is required between the motor circuit and control logic, verify that signal isolators or relay output modules (such as the 3RQ3 relay module) are functioning within specification.
Finally, review the fuse protection upstream of the motor starter — NH fuse links or miniature circuit breakers protecting the feeder circuit should be rated and coordinated with the 3RV6011-1BA15’s breaking capacity. Miscoordination is a common source of nuisance tripping and equipment damage during fault events. Documenting all findings in a maintenance log supports lifecycle planning and justifies spare parts stocking decisions for future procurement cycles.
Site Replacement Workflow
Step 1 — Isolation & Lockout/Tagout (LOTO): De-energize the motor feeder circuit at the upstream disconnect or MCC section. Apply LOTO per site safety procedures. Verify absence of voltage at the 3RV6011-1BA15 input terminals using a calibrated voltage tester.
Step 2 — Documentation: Photograph the existing wiring, terminal assignments, and DIP switch / current adjustment dial setting on the outgoing unit. Record the trip current setting (Ir) — for the 3RV6011-1BA15, this is set within the 1.4–2.0 A range using the rotary dial on the front face.
Step 3 — Removal: Disconnect load and line cables from the terminal screws. If a 3RV6901 auxiliary contact block or 3RV6921 alarm switch is attached, remove it carefully for reuse. Unclip the unit from the DIN rail or unscrew from the mounting plate.
Step 4 — Installation of Replacement Unit: Mount the new 3RV6011-1BA15 on the DIN rail. Reconnect line and load cables to the correct terminals (L1/T1, L2/T2, L3/T3). Reattach the auxiliary contact block. Set the rotary current dial to the previously recorded Ir value.
Step 5 — Functional Test: Re-energize the circuit. Perform a manual trip test using the TEST button (if accessible). Confirm PLC feedback signal indicates READY status. Run the motor under no-load, then full-load conditions, monitoring for unexpected trips or thermal alarms.
Step 6 — Documentation & Handover: Update the maintenance log with the replacement date, new unit serial number, and test results. File the 12-month warranty documentation from NINERMAS for future reference.
This workflow is compatible with legacy SIRIUS 3RV1 installations where the 3RV6011-1BA15 serves as a direct functional replacement, maintaining system compatibility without panel modification.
Spare Parts Support FAQ
Q1: Is the 3RV6011-1BA15 a direct replacement for the older 3RV1011-1BA10?
Yes. The 3RV6 series is the successor to the 3RV1 series. The 3RV6011-1BA15 is dimensionally and functionally compatible with 3RV1011-1BA10 installations, including the same S00 frame size, DIN rail mounting, and SIRIUS combination starter interfaces. No panel modification is required for a direct swap.
Q2: What is included in the 12-month warranty and how is a claim processed?
NINERMAS provides a 12-month warranty from the date of shipment covering manufacturing defects and operational failures under normal industrial service conditions. To initiate a warranty claim, contact sale@ninermas.com with the order reference, unit serial number, and a description of the fault. Replacement or repair is arranged within the warranty period at no additional cost.
Q3: Can NINERMAS support long-term or blanket purchase orders for the 3RV6011-1BA15?
Yes. NINERMAS supports long-term supply agreements and blanket PO arrangements for critical spare parts including the 3RV6011-1BA15. This is particularly valuable for facilities managing aging SIRIUS motor control infrastructure where OEM supply lead times are unpredictable. Contact our sales team to discuss stocking commitments, pricing tiers, and delivery scheduling.
Q4: How is the 3RV6011-1BA15 tested before shipment?
Every unit undergoes pre-shipment functional inspection including continuity verification, insulation resistance check, and manual trip mechanism test. Units are packaged in anti-static, shock-resistant packaging to prevent transit damage. A test report is available upon request for quality-critical procurement requirements.
| Product Series | SIRIUS |
|---|---|
| Country of Origin | DE |
Catalog Continuation
More Siemens modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: 6FC5603-0AC12-1AA0
Siemens 6FC5603-0AC12-1AA0 Service-Ready Spare Part
SKU: C98043-A1305-L1-08
SIEMENS C98043-A1305-L1-08 Retrofit-Compatible Control Board for Legacy Systems
Catalog Continuation
Alternative parts within PLC & Industrial Automation Modules.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 2-12V HPM5B6BEA1A1F1S235 QLZ 80 3D80-001918-12 MDC-01A
Power-One HPM5B6BEA1A1F1S235 Retrofit Power Supply for Legacy
SKU: VLB20105 V003048.B02