Original Industrial Spare Part
Bently Nevada 330104-00-06-05-02-00 Service-Ready Spare Part
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU330104-00-06-05-02-00
- CategoryTSI & Rotating Machinery Monitoring
- BrandBently Nevada
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Bently Nevada 330104-00-06-05-02-00 Service-Ready Spare Part with SKU 330104-00-06-05-02-00.
Bently Nevada 330104-00-06-05-02-00 Service-Ready Spare Part: Precision Proximity Probe for Downtime Risk Control
The Bently Nevada 330104-00-06-05-02-00 is a ruggedized proximity probe module from the industry-standard 3300 Series proximity transducer system, engineered for continuous vibration and position monitoring in rotating machinery applications. Designed to operate reliably in harsh industrial environments — including high-temperature, high-vibration, and chemically aggressive atmospheres — this probe module is a critical spare part for maintenance engineers managing turbines, compressors, pumps, and other rotating assets in oil and gas, power generation, petrochemical, and heavy manufacturing facilities.
At NINERMAS, every 330104-00-06-05-02-00 unit is sourced as an original Bently Nevada component, pre-shipment tested, and dispatched with a 12-month warranty. Our inventory is maintained specifically to support emergency replacement, planned annual overhaul, and long-term spare parts programs — ensuring your critical machinery stays online and your maintenance team is never left waiting for a part.
Spare Maintenance Table
| Parameter | Specification / Detail |
|---|---|
| Part Number / SKU | 330104-00-06-05-02-00 |
| Brand | Bently Nevada |
| Series | 3300 Series Proximity Transducer System |
| Product Type | Ruggedized Proximity Probe Module |
| Probe Length | 6 inches (as indicated by SKU segment -06-) |
| Cable Length | 5 metres (as indicated by SKU segment -05-) |
| Output Signal | -24 VDC nominal (eddy-current, non-contacting) |
| Sensitivity | 200 mV/mil (7.87 V/mm) nominal |
| Operating Temperature | -35°C to +177°C (probe tip); cable rated for harsh environments |
| Target Material Compatibility | AISI 4140 steel and equivalent ferromagnetic alloys |
| Connector Type | Ruggedized, armoured cable assembly |
| Compatibility | 3300 XL 8mm Proximity Transducer System; 3300 NSv; compatible with Bently Nevada 3500 Series rack monitors |
| Application Environment | Turbines, compressors, pumps, gearboxes — oil & gas, power, petrochemical |
| Installation | Threaded mounting; gap set per OEM specification (typically 1.0–1.5 mm) |
| Maintenance Recommendation | Replace during planned outage or immediately upon signal drift / alarm condition |
| Origin | United States |
| Warranty | 12 Months — NINERMAS Quality Guarantee |
| Availability | In Stock — Ready to Ship |
Maintenance Planning for Continuous Operation
When a 330104-00-06-05-02-00 proximity probe reaches end-of-life or triggers a high-vibration alarm, experienced maintenance engineers know that a single component replacement is rarely the complete picture. A thorough site inspection and coordinated spare parts review will significantly reduce the risk of repeat failures and unplanned downtime.
Begin by inspecting the extension cable (typically the Bently Nevada 330130 series) that connects the probe to the proximitor. Extension cables are subject to mechanical fatigue, connector corrosion, and insulation degradation in high-temperature environments — a failed probe is often accompanied by a compromised cable. Simultaneously, verify the condition of the proximitor / signal conditioner (such as the 3300 XL proximitor, e.g. 330180 series), which converts the raw eddy-current signal into a usable -24 VDC output for the monitoring rack.
At the rack level, confirm that the Bently Nevada 3500/40M proximitor I/O module or equivalent rack-mounted I/O card is functioning within specification. Signal drift at the probe can mask underlying issues in the I/O module’s input circuitry. If the installation uses a 3500/20 power supply module, inspect it for output voltage stability — an under-voltage condition will cause erratic probe readings even with a new probe installed.
For installations integrated with a Bently Nevada 3500 Series monitoring rack, also review the 3500/01 rack interface module and any installed communication gateway modules (such as the 3500/92 or Modbus/TCP interface cards) to ensure alarm data is being correctly transmitted to the plant DCS or SCADA system. A probe replacement that is not followed by a communications check can leave operators blind to new alarm conditions.
In control cabinet environments, check the terminal blocks and field wiring connecting the proximitor output to the monitoring rack. Loose terminations and corroded terminal strips are a leading cause of intermittent vibration alarms. Where signal runs are long or routed near high-voltage equipment, inspect any installed signal isolators or signal conditioners in the measurement loop for drift or failure.
Finally, for rotating machinery that also uses Keyphasor probes (e.g., Bently Nevada 330980 series) for phase reference and speed measurement, confirm that the Keyphasor signal is clean and correctly gapped. A degraded Keyphasor signal will compromise the accuracy of all vector-based vibration measurements taken from the newly replaced proximity probe, undermining the value of the replacement work.
Maintaining a coordinated spare parts inventory — covering the probe, extension cable, proximitor, I/O module, power supply, and terminal hardware — is the most effective strategy for minimising mean time to repair (MTTR) and protecting asset availability.
Site Replacement Workflow
Step 1 — Isolation and Permit: Obtain a valid work permit and isolate the monitoring channel at the 3500 rack before removing the probe. Do not de-energise the full rack unless required by site procedure, as this will affect all monitored channels.
Step 2 — Probe Removal: Carefully unthread the 330104-00-06-05-02-00 probe from its mounting boss. Note the existing gap measurement (typically recorded in the maintenance log) and inspect the mounting threads for damage or corrosion.
Step 3 — Cable and Connector Inspection: Before installing the replacement probe, inspect the full length of the extension cable for kinking, abrasion, or connector damage. Replace the extension cable if any defects are found — installing a new probe on a degraded cable will not restore system performance.
Step 4 — Installation and Gap Setting: Install the replacement 330104-00-06-05-02-00 and set the air gap per the OEM specification for the target shaft material (typically 1.0–1.5 mm for standard steel targets). Use a calibrated gap-setting tool or digital multimeter to verify the DC output voltage at the proximitor output terminal.
Step 5 — Signal Verification: With the channel active, confirm that the DC output voltage is within the linear range (-10 to -18 VDC typical for a correctly gapped 3300 XL system). Check for noise, signal instability, or unexpected alarm conditions at the 3500 rack display or DCS workstation.
Step 6 — Documentation: Record the replacement in the equipment maintenance log, including the new probe serial number, gap voltage, and date of installation. Update the spare parts inventory to trigger replenishment of the consumed 330104-00-06-05-02-00 unit.
Following this structured workflow ensures that the replacement restores full system compatibility, maintains alarm integrity, and leaves a clear audit trail for future maintenance planning — all critical requirements for facilities operating under ISO 55000 asset management or API 670 machinery protection standards.
Spare Parts Support FAQ
Q1: Is the 330104-00-06-05-02-00 compatible with both the 3300 XL and the older 3300 NSv proximity transducer systems?
Yes. The 330104 probe series is designed for use within the Bently Nevada 3300 proximity transducer ecosystem, which includes the 3300 XL 8mm system and the 3300 NSv. Compatibility with the 3500 Series monitoring rack is maintained through the standard proximitor interface. Always verify the target material and gap specification against your site’s OEM documentation before installation.
Q2: What pre-shipment testing does NINERMAS perform on the 330104-00-06-05-02-00?
Every unit dispatched by NINERMAS undergoes electrical continuity verification, insulation resistance check, and visual inspection for connector and cable integrity. Units are packaged in anti-static, impact-resistant packaging to prevent transit damage. A 12-month warranty is included with every shipment, covering manufacturing defects and functional failures under normal operating conditions.
Q3: Can NINERMAS support a long-term spare parts supply agreement for the 330104-00-06-05-02-00?
Yes. NINERMAS specialises in long-term spare parts programs for legacy and current-production Bently Nevada components. We can reserve dedicated stock, provide scheduled delivery against annual maintenance plans, and offer volume pricing for multi-unit procurement. Contact our team to discuss a supply agreement tailored to your facility’s maintenance schedule.
Q4: What should I do if the replacement probe does not resolve the vibration alarm after installation?
If the alarm persists after installing a new 330104-00-06-05-02-00 and verifying the gap voltage, the fault is likely upstream in the signal chain. Systematically check the extension cable, proximitor output, I/O module input, and rack power supply voltage. If all components test within specification, the issue may be a genuine machinery fault (e.g., bearing wear, shaft runout) rather than an instrumentation failure — in which case, the monitoring system is functioning correctly and the machinery requires mechanical inspection.
| Product Series | 3300 Series |
|---|---|
| Country of Origin | US |
Catalog Continuation
More Bently Nevada modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: 330881-28-05-060-00-02
Bently Nevada 330881-28-05-060-00-02 Safety-Reliable Proximity Module
SKU: 21000-00-00-00-042-03-02
Bently Nevada 21000-00-00-00-042-03-02 Service-Ready Spare Part
Catalog Continuation
Alternative parts within TSI & Rotating Machinery Monitoring.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 21000-16-10-15-092-03-02
Bently Nevada 21000-16-10-15-092-03-02 Service-Ready Spare Part
SKU: 21000-28-05-00-041-03-02
Bently Nevada 21000-28-05-00-041-03-02 Retrofit Vibration Monitor
SKU: BENTLY NEVADA 991-01-XX-01-05 MOD 288865-01 Thrust Transmitter
Bently Nevada 991-01 MOD 288865-01 Safety Thrust Transmitter