Original Industrial Spare Part
GE DS200TCCAG1RJB Service-Ready Spare Part for Industrial Maintenance
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUDS200TCCAG1RJB
- CategoryDCS Distributed Control Systems
- BrandGE
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: GE DS200TCCAG1RJB Service-Ready Spare Part for Industrial Maintenance with SKU DS200TCCAG1RJB.
GE DS200TCCAG1RJB Service-Ready Spare Part for Industrial Maintenance
The GE DS200TCCAG1RJB is a critical turbine control module designed for use within the GE Mark VI Turbine Control System — one of the most widely deployed control platforms in gas turbine, steam turbine, and combined-cycle power generation facilities worldwide. As aging Mark VI installations continue to operate beyond their original design life, maintaining a reliable inventory of service-ready spare parts such as the DS200TCCAG1RJB becomes essential for uninterrupted plant operation, rapid fault recovery, and long-term lifecycle extension.
At NINERMAS, every DS200TCCAG1RJB unit is sourced, inspected, and pre-shipment tested to confirm electrical integrity and functional readiness before dispatch. Our supply chain supports both emergency replacement orders and planned annual maintenance programs, with stock availability confirmed prior to order acceptance. Each unit is backed by a 12-month warranty, giving maintenance engineers and procurement teams confidence in both quality and long-term supply continuity.
Whether you are responding to an unplanned turbine trip, executing a scheduled outage, or building a strategic spare parts buffer for a critical asset, the DS200TCCAG1RJB is available for immediate dispatch with full compatibility documentation upon request.
Spare Maintenance Table
| Parameter | Details |
|---|---|
| Part Number | DS200TCCAG1RJB |
| Manufacturer | GE (General Electric) |
| Series | Mark VI Turbine Control System |
| Module Type | Turbine Control / Communication Module |
| Application | Gas Turbine, Steam Turbine, Combined-Cycle Power Plants |
| Compatibility | GE Mark VI, Mark VIe control cabinets; compatible with VCMI, VSVO, VTUR, VGEN I/O packs |
| Operating Environment | Industrial control cabinet; temperature-controlled enclosure recommended |
| Installation | Rack-mount, backplane-integrated; follows GE Mark VI wiring and termination standards |
| Communication Interface | IONet / Ethernet-based Mark VI internal network |
| Pre-Shipment Testing | Yes — functional and electrical integrity verified before dispatch |
| Warranty | 12 Months from date of shipment |
| Lead Time | In-stock units available for same-day or next-day dispatch |
| Condition | Refurbished / Surplus New (confirmed per unit) |
| Origin | United States |
| Supply Model | Emergency replacement, planned maintenance, long-term spare parts program |
Maintenance Planning for Continuous Operation
When replacing the DS200TCCAG1RJB in a Mark VI turbine control cabinet, experienced maintenance engineers understand that a single module swap rarely tells the full story. A thorough site inspection and cabinet audit should accompany any DS200TCCAG1RJB replacement to prevent repeat faults and ensure system-wide stability.
Begin by auditing the Mark VI backplane and VME rack for signs of corrosion, loose connectors, or damaged bus traces — backplane degradation is a common root cause of intermittent module faults in aging installations. Inspect the VCMI (VME Communications Module Interface) and confirm that IONet communication is stable across all connected I/O packs. A faulty VCMI can cause the DS200TCCAG1RJB to report false diagnostics or fail to initialize correctly after replacement.
Check the VSVO (Servo Output Module) and VTUR (Turbine I/O Pack) for alarm history and verify that servo valve feedback signals are within expected ranges. If the turbine experienced a hard trip prior to the DS200TCCAG1RJB failure, the VGEN (Generator I/O Pack) should also be inspected for latched faults or damaged signal conditioning circuits.
On the power supply side, verify that the Mark VI 28VDC power distribution modules are delivering stable, within-tolerance voltage to all rack positions. Voltage sag or ripple on the DC bus is a known contributor to premature module failure in high-density Mark VI cabinets. Inspect terminal blocks and field wiring terminations for tightness and insulation integrity — loose terminations on thermocouple or RTD inputs can introduce noise that degrades control module performance.
For sites running HMI workstations connected to the Mark VI via the Unit Data Highway (UDH), confirm that network switches and Ethernet patch cables are functioning correctly. Communication faults between the HMI and the Mark VI controller can sometimes be misdiagnosed as module-level failures. Additionally, inspect any signal isolators or signal conditioners used on 4–20mA process inputs to the turbine control system — degraded isolators can introduce ground loops that affect module diagnostics.
Finally, review the status of protective relays in the generator protection panel and confirm that trip logic associated with the turbine control system has been reset and verified following the DS200TCCAG1RJB replacement. A complete functional test of the turbine start sequence, load ramp, and trip response should be performed before returning the unit to service.
Site Replacement Workflow
Step 1 — Compatibility Confirmation: Before ordering, provide your Mark VI cabinet serial number, software revision, and existing module configuration to NINERMAS. Our technical team will confirm DS200TCCAG1RJB compatibility with your specific installation and advise on any firmware or configuration considerations.
Step 2 — Safe Isolation: Follow GE Mark VI lockout/tagout procedures. De-energize the affected rack section and allow capacitors to discharge before removing the existing module. Document the current module position, connector orientation, and any jumper or DIP switch settings.
Step 3 — Module Swap: Install the replacement DS200TCCAG1RJB into the correct rack slot, ensuring the backplane connector is fully seated. Reconnect all field wiring terminations per the original GE wiring diagram. Do not substitute connector types or modify termination sequences.
Step 4 — Power-Up and Diagnostics: Re-energize the rack and observe the module’s LED status indicators during initialization. Access the Mark VI Toolbox software to confirm that the DS200TCCAG1RJB is recognized by the controller and that no new diagnostic alarms are present. Clear any latched alarms from the prior fault event.
Step 5 — Functional Verification: Perform a controlled turbine start sequence in test mode where possible. Verify I/O signal integrity, servo response, and communication status across all connected I/O packs before returning the turbine to automatic operation. Log the replacement event in your CMMS for warranty tracking and future maintenance planning.
Spare Parts Support FAQ
Q1: Is the DS200TCCAG1RJB compatible with both Mark VI and Mark VIe systems?
The DS200TCCAG1RJB is primarily associated with the GE Mark VI platform. Compatibility with Mark VIe installations depends on the specific cabinet configuration and software revision. NINERMAS recommends providing your cabinet documentation for a compatibility review before ordering to avoid installation issues.
Q2: What testing is performed before shipment?
Every DS200TCCAG1RJB unit undergoes pre-shipment functional and electrical integrity testing at NINERMAS. This includes power-up verification, communication interface checks, and visual inspection for physical damage. A test report is available upon request. Units that do not pass testing are not dispatched.
Q3: Can NINERMAS support long-term spare parts supply for Mark VI systems?
Yes. NINERMAS operates a long-term spare parts program for GE Mark VI and related turbine control platforms. We can support annual maintenance schedules, multi-year supply agreements, and emergency stock reservation for critical assets. Contact our team to discuss a tailored spare parts support plan for your facility.
Q4: What does the 12-month warranty cover?
The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions from the date of shipment. It does not cover damage resulting from incorrect installation, overvoltage events, or unauthorized modification. NINERMAS provides replacement or repair support for any warranted claim within the coverage period.
| Product Series | Mark VI |
|---|---|
| Country of Origin | US |
Catalog Continuation
Nearby part numbers around DS200TCC.
Use this lane when the buyer is comparing adjacent model numbers, revision-near items, or closely related spare variants within the same brand family.
Catalog Continuation
More GE modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: VVIB H1C IS200VVIBH1CAC
GE IS200VVIBH1CAC Service-Ready Spare Part for Industrial Maintenance
SKU: DS200RTBAG3AHC
GE DS200RTBAG3AHC Relay Terminal Board | Mark V Speedtronic
Catalog Continuation
Alternative parts within DCS Distributed Control Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: CC-TD0R01 51308376-175
Honeywell CC-TD0R01 51308376-175 Spare Part for Maintenance
SKU: CE4006P2 KJ3241X1-BA1 12P2506X102
EMERSON CE4006P2 KJ3241X1-BA1 12P2506X102 DeltaV I/O
SKU: 8C-PCNT02 51454363-275
Honeywell 8C-PCNT02 51454363-275 Spare Part for Maintenance
SKU: 3BSE003127R1 DSAI130D