Siemens 6SL3320-1TE33-1AA3 Retrofit-Compatible Motor Module: Legacy System Compatibility & Smooth Upgrade

The Siemens 6SL3320-1TE33-1AA3 is a Single Motor Module from the SINAMICS S120 booksize drive series, designed to deliver precise torque and speed control for demanding industrial servo and vector drive applications. As legacy automation systems age and original spare parts become increasingly difficult to source, the 6SL3320-1TE33-1AA3 has become a critical retrofit and replacement component for engineers tasked with modernizing older production lines, upgrading control cabinets, and extending the operational life of existing drive infrastructure.

Whether you are replacing a discontinued SIMODRIVE 611 axis module, migrating from an older SINAMICS S120 chassis unit, or consolidating a multi-axis drive cabinet onto a booksize platform, the 6SL3320-1TE33-1AA3 offers a well-supported upgrade path with broad compatibility across Siemens drive ecosystems. Its rated output current and DC link voltage range make it suitable for medium-power servo axes in machine tools, packaging lines, printing presses, and material handling systems.

Upgrade Compatibility Table

Parameter Details
SKU / Part Number 6SL3320-1TE33-1AA3
Series SINAMICS S120 Booksize
Module Type Single Motor Module
DC Link Interface Shared DC bus via booksize backplane connector
Drive-CLiQ Communication Compatible with SINAMICS S120 CU320-2 DP / CU320-2 PN Control Units
Installation Format Booksize — requires compatible S120 booksize mounting rail and DC link busbar
Cooling Method Internal fan / forced air cooling
Common Replacement For SIMODRIVE 611 axis modules, older S120 booksize motor modules
Communication Protocol PROFIBUS DP / PROFINET (via Control Unit)
Retrofit Recommendation Verify DC link voltage, motor cable terminal assignment, and Drive-CLiQ topology before installation
Commissioning Tool STARTER / SINAMICS Startdrive (TIA Portal)
Warranty 12 Months

Retrofit Planning for Existing Automation Systems

Successful integration of the 6SL3320-1TE33-1AA3 into an existing automation system requires careful pre-installation planning. Engineers should begin by auditing the current drive cabinet layout to confirm available mounting space on the booksize rail. The module slots directly into the shared DC bus architecture, so the existing SINAMICS S120 Line Module — whether an Active Line Module (ALM) or Basic Line Module (BLM) — must be verified for sufficient DC link power capacity to support the additional motor axis.

Terminal wiring is a critical step. Motor power terminals (U2, V2, W2) and the motor holding brake connector must be mapped against the existing cable harness. If the legacy system used a SIMODRIVE 611 NE/NR module or an older chassis-format drive, the motor cable may require re-termination or an adapter to match the booksize connector pitch. The SINAMICS S120 Sensor Module Cabinet-Mounted (SMC) or an integrated encoder interface on the motor module must be configured to match the feedback type — whether resolver, TTL incremental encoder, or absolute encoder such as EnDat or SSI.

Drive-CLiQ topology must be planned before commissioning. The 6SL3320-1TE33-1AA3 connects to the CU320-2 DP or CU320-2 PN Control Unit via Drive-CLiQ cable. In multi-axis configurations, the daisy-chain sequence of motor modules, the SINAMICS S120 Double Motor Module (if used on adjacent axes), and any connected SMC30 or SMC20 sensor modules must be correctly ordered in the Drive-CLiQ ring to avoid topology errors during startup.

For systems communicating over PROFIBUS DP, the existing GSD file and axis parameter block assignments in the PLC program — typically a Siemens SIMATIC S7-300 or S7-400 — must be reviewed to ensure the drive object address and telegram type (e.g., Telegram 105 or 111) remain consistent after module replacement. If the plant is migrating to PROFINET, the CU320-2 PN variant enables a direct protocol upgrade without changing the motor module hardware, significantly reducing re-engineering effort.

HMI screens linked to drive status words, fault codes, and speed setpoints — often displayed on a SIMATIC HMI TP700 or TP1200 Comfort Panel — should be validated against the new drive parameter set. Fault message mapping and process variable tags may require updates in WinCC or TIA Portal if the drive firmware version changes during the retrofit.

Power supply integrity is another key consideration. The SITOP PSU8600 or SITOP modular 24 V DC power supply feeding the control electronics must be confirmed to provide stable 24 V DC within the specified tolerance range. Voltage dips during motor acceleration can cause control unit resets if the power supply is undersized for the expanded drive configuration.

Downtime Control During System Migration

Minimizing production downtime during a drive module replacement is a primary concern for maintenance teams. A structured migration approach begins with a full parameter backup of the existing drive configuration using STARTER or SINAMICS Startdrive before any hardware is removed. This backup preserves all axis parameters, speed controller gains, current limits, encoder settings, and safety function configurations, allowing rapid restoration if commissioning issues arise.

Where possible, the replacement 6SL3320-1TE33-1AA3 should be pre-configured offline using the saved parameter file. Drive-CLiQ automatic topology detection will identify the new module upon first power-up, but the parameter download must be performed before enabling the axis to avoid running with factory default settings. Pre-testing the module on a bench setup with a representative motor load — using a SINAMICS S120 CU310-2 DP compact control unit if available — can validate the configuration before installation in the live cabinet.

During the physical swap, the DC link must be fully discharged before disconnecting the busbar. The discharge time for the S120 booksize DC link capacitors is typically several minutes after mains disconnection; always verify with a calibrated DC voltmeter before touching DC link terminals. Labeling all motor cables, encoder connectors, and Drive-CLiQ cables before removal eliminates reconnection errors and reduces commissioning time significantly.

After installation, a controlled first-run sequence — starting with the drive in speed control mode at low setpoint with the mechanical load disconnected if possible — allows verification of encoder feedback direction, current controller response, and fault-free operation before returning the axis to full production speed. Field commissioning records, including measured no-load current, speed reference tracking, and any active safety function test results, should be documented to support the 12-month warranty claim process and future maintenance audits.

Retrofit Support FAQ

Q1: Is the 6SL3320-1TE33-1AA3 a direct replacement for my existing SINAMICS S120 booksize motor module?
A: In most cases, yes — provided the replacement module shares the same rated output current and DC link voltage class as the original. Always cross-reference the full order number and firmware compatibility with your existing Control Unit version. Our technical team can assist with compatibility verification before shipment.

Q2: What wiring changes are required when retrofitting from a SIMODRIVE 611 system?
A: SIMODRIVE 611 and SINAMICS S120 use different connector formats and DC bus architectures. Motor power cables will typically require re-termination, and the feedback interface must be adapted to Drive-CLiQ or an appropriate SMC sensor module. A full wiring diagram review is recommended prior to installation.

Q3: Has this unit been tested before shipment?
A: Yes. All units undergo functional power-on testing and parameter verification before dispatch. Each module is inspected for physical integrity, connector condition, and firmware version. A test report is available upon request.

Q4: What does the 12-month warranty cover?
A: The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions. It does not cover damage resulting from incorrect installation, overvoltage events, or operation outside the specified environmental ratings. Warranty claims are supported with full technical documentation and replacement dispatch within agreed lead times.

Product Series

SINAMICS

Country of Origin

DE

Catalog Continuation

More Siemens modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack