Original Industrial Spare Part

SIEMENS 6SE7090-0XX87-4AH0 Retrofit Communication Module

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: 6SE7090-0XX87-4AH0 PLC & Industrial Automation Modules Siemens

RFQ Ready

Pricing by RFQ

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

SIEMENS 6SE7090-0XX87-4AH0 Retrofit Communication Module: Legacy System Compatible Upgrade

The SIEMENS 6SE7090-0XX87-4AH0 is a PROFIBUS-DP communication board (CBP2) designed for the SIMOVERT MASTERDRIVES MC and VC series variable frequency drive platform. As Siemens progressively phases out legacy MASTERDRIVES hardware, plant engineers and maintenance teams face increasing pressure to source verified replacement communication modules that maintain full compatibility with existing PROFIBUS network topologies, drive parameter sets, and PLC control architectures. NINERMAS maintains verified stock of the 6SE7090-0XX87-4AH0 to support retrofit projects, emergency spare part replacement, and long-term maintenance contracts — backed by a 12-month warranty and pre-shipment functional testing.

Whether you are replacing a failed CBP2 board in a running production line, upgrading a legacy control cabinet, or executing a phased MASTERDRIVES modernization program, the 6SE7090-0XX87-4AH0 provides a direct, slot-compatible replacement that eliminates the need for drive parameter re-engineering or PROFIBUS segment reconfiguration. This module slots into the option board bay of the MASTERDRIVES chassis and communicates via the internal drive bus, making it a preferred choice for maintenance teams seeking to minimize downtime and preserve existing automation logic.

Upgrade Compatibility Table

Parameter Details
SKU / Part Number 6SE7090-0XX87-4AH0
Module Type CBP2 PROFIBUS-DP Communication Board
Compatible Platform SIMOVERT MASTERDRIVES MC / VC Series
Communication Protocol PROFIBUS-DP (up to 12 Mbit/s)
Installation Interface Option Board Slot (internal drive bus)
Replaces / Supersedes 6SE7090-0XX87-4AH0 (same generation), CBP / CBP2 variants
PLC Compatibility SIMATIC S5, S7-300, S7-400, S7-1500 (via PROFIBUS master)
HMI Compatibility SIMATIC OP/TP panels, WinCC via PROFIBUS
Commissioning Tool DriveMonitor, STARTER, SIMATIC PDM
Installation Space Standard MASTERDRIVES option slot — no chassis modification required
Pre-Shipment Testing Yes — functional communication verification performed
Warranty 12 Months from date of shipment

Retrofit Planning for Existing Automation Systems

A successful retrofit of the 6SE7090-0XX87-4AH0 into an existing MASTERDRIVES installation requires a structured pre-replacement assessment. Before removing the failed communication board, maintenance engineers should document the current PROFIBUS node address configured on the CBP2 — this is typically set via DIP switches on the board itself and must be replicated exactly on the replacement module to avoid PROFIBUS address conflicts that would disrupt the entire network segment.

Power supply capacity within the control cabinet must be verified prior to installation. The MASTERDRIVES chassis internal 24 VDC bus supplies the option board; confirm that the existing SITOP PSU8600 or equivalent 24 V regulated power supply has sufficient headroom to support the communication board alongside other installed option modules such as the SBP encoder evaluation board or the CBC CAN Bus board. In multi-axis installations where several MASTERDRIVES units share a common DC bus via the 6SE7090-0XX84-0AA0 DC bus connector, the aggregate option board power draw must be reviewed.

Terminal wiring for the PROFIBUS-DP connector (9-pin Sub-D) should be inspected for cable shielding continuity and correct termination resistor placement at both ends of the PROFIBUS segment. Improper termination is a common source of intermittent communication faults after board replacement. If the existing PROFIBUS cable is aged or shows insulation degradation, replacement with a new PROFIBUS FC Standard Cable is recommended before commissioning the new 6SE7090-0XX87-4AH0.

For sites running SIMATIC S7-300 or S7-400 PLCs as the PROFIBUS master, the GSD file (device description file) for the CBP2 must be present in the STEP 7 hardware configuration. If the GSD file is missing or outdated, download the current version from the Siemens support portal and re-import it before performing a hardware configuration download. This step is critical to ensure the PLC correctly identifies the drive’s process data objects (PKW and PZD channels) and that the existing FB/FC drive control blocks — such as those used with the MASTERDRIVES function block library — continue to operate without modification.

In installations where the MASTERDRIVES communicates with a SIMATIC HMI panel (OP270, TP270, or MP370 series) via PROFIBUS, verify that the HMI project’s drive variable tags reference the correct PROFIBUS address and slot configuration. After replacing the 6SE7090-0XX87-4AH0, perform a full HMI communication test to confirm that speed setpoints, fault acknowledgement, and status word displays function correctly before returning the line to production.

Sites planning a longer-term migration from MASTERDRIVES to the SINAMICS S120 platform should note that the SINAMICS CU320-2 DP control unit supports PROFIBUS-DP natively, allowing the existing PROFIBUS wiring infrastructure and PLC program to be retained during the transition. The 6SE7090-0XX87-4AH0 replacement extends the operational life of the MASTERDRIVES platform while the migration is planned and budgeted, avoiding forced emergency upgrades driven by communication board failure. Related components commonly required during this transition phase include the SINAMICS S120 booksize power module, the SMC30 encoder evaluation module, the TM31 terminal expansion module for analog and digital I/O mapping, and the CBE20 PROFINET communication board for sites planning a future protocol migration from PROFIBUS to PROFINET.

Downtime Control During System Migration

Minimizing production downtime during a MASTERDRIVES communication board replacement requires advance preparation and a disciplined commissioning sequence. Before scheduling the maintenance window, obtain the current drive parameter set by uploading it from the MASTERDRIVES unit using DriveMonitor or STARTER software connected via the RS232 serial interface (using the appropriate PC adapter cable). Save the parameter file to a secure location — this backup is essential for restoring drive behavior if the replacement board triggers any parameter reset during installation.

The physical board swap on the 6SE7090-0XX87-4AH0 is a tool-free operation: power down the drive, discharge the DC bus capacitors per the MASTERDRIVES safety procedure (minimum 5-minute wait after power-off), remove the option board cover, extract the existing CBP2 board, and seat the replacement module firmly into the option slot until the retention clips engage. Verify the PROFIBUS node address DIP switch setting matches the documented address before powering up.

On power-up, monitor the PROFIBUS status LED on the new 6SE7090-0XX87-4AH0 — a steady green LED indicates successful PROFIBUS data exchange with the PLC master. If the LED shows a flashing pattern, check the PROFIBUS address, cable termination, and GSD file configuration in the PLC hardware project. In most cases, a correctly prepared replacement results in full PROFIBUS communication restoration within 15–30 minutes of the maintenance window start, keeping unplanned downtime to an absolute minimum.

For critical production lines where even brief downtime is unacceptable, NINERMAS recommends maintaining a dedicated on-site spare of the 6SE7090-0XX87-4AH0 as part of a structured spare parts lifecycle program. Combined with a documented replacement procedure and a pre-tested parameter backup file, this approach reduces mean time to repair (MTTR) to under 30 minutes and eliminates the risk of extended outages caused by long international lead times for discontinued Siemens MASTERDRIVES components.

Retrofit Support FAQ

Q1: Is the 6SE7090-0XX87-4AH0 a direct drop-in replacement for the original CBP2 board in my MASTERDRIVES unit?
Yes. The 6SE7090-0XX87-4AH0 is the standard CBP2 PROFIBUS-DP communication board for the SIMOVERT MASTERDRIVES platform. It installs into the same option board slot without chassis modification and uses the same PROFIBUS-DP protocol and GSD file as the original board. No drive parameter re-engineering is required provided the PROFIBUS node address DIP switches are set to match the original configuration.

Q2: What commissioning steps are required after installing the replacement board?
After installation, verify the PROFIBUS node address DIP switch setting, power up the drive, and confirm the PROFIBUS status LED shows steady green. Perform a PLC online diagnostic to confirm the drive appears on the PROFIBUS segment without faults. Test speed setpoint commands, fault acknowledgement, and status word readback from the PLC. If an HMI is connected, verify all drive-related screen objects display correctly. Total commissioning time is typically 15–30 minutes for a prepared maintenance team.

Q3: Has the 6SE7090-0XX87-4AH0 been tested before shipment, and what warranty is provided?
Yes. All units supplied by NINERMAS undergo pre-shipment functional testing to verify communication board integrity and PROFIBUS interface operation. Each unit is covered by a 12-month warranty from the date of shipment. In the event of a warranty claim, NINERMAS provides replacement or repair support with priority handling to minimize impact on your production operations.

Q4: Can NINERMAS supply the 6SE7090-0XX87-4AH0 for long-term maintenance contracts and bulk spare parts programs?
Yes. NINERMAS maintains verified inventory of the 6SE7090-0XX87-4AH0 and related MASTERDRIVES spare parts to support long-term maintenance agreements, annual spare parts budgets, and emergency procurement requirements. Contact our technical sales team to discuss volume pricing, lead times, and consignment stock arrangements tailored to your plant’s maintenance strategy.

Product Series

SIMOVERT

Country of Origin

DE

Catalog Continuation

More Siemens modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack