Original Industrial Spare Part

SIEMENS 6SL3351-6GE35-0AA1 Retrofit-Compatible Control Interface

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: 6SL3351-6GE35-0AA1 PLC & Industrial Automation Modules Siemens

RFQ Ready

Pricing by RFQ

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

SIEMENS 6SL3351-6GE35-0AA1 Retrofit-Compatible Control Interface for Legacy System Modernization

The SIEMENS 6SL3351-6GE35-0AA1 is a ruggedized control interface module engineered for demanding industrial environments and purpose-built to support seamless integration into legacy SINAMICS drive system retrofits. As production lines age and original equipment manufacturers discontinue support for older drive platforms, the 6SL3351-6GE35-0AA1 has become a critical component in control cabinet upgrades, I/O expansion projects, and full-system modernization programs across manufacturing, energy, and process industries. Whether you are replacing a failed unit in an existing SINAMICS S120 chassis or executing a planned migration away from an end-of-life drive platform, this module delivers the interface reliability and environmental resilience required for uninterrupted production continuity.

Upgrade Compatibility Table

Parameter Details
SKU / Part Number 6SL3351-6GE35-0AA1
Series SINAMICS S120
Module Type Ruggedized Control Interface Module
Mounting / Installation Booksize / Chassis format; compatible with standard SINAMICS S120 backplane and drive line-up
Communication Compatibility DRIVE-CLiQ; compatible with PROFIBUS DP and PROFINET IO upstream controllers
Replacement Recommendation Direct replacement for equivalent legacy SINAMICS control interface variants; verify firmware revision before commissioning
Commissioning Notes Confirm terminal wiring, module address assignment, and STARTER / TIA Portal project upload prior to energizing
Warranty 12-Month Warranty included with every unit

Retrofit Planning for Existing Automation Systems

Successful retrofit of the 6SL3351-6GE35-0AA1 into an existing control architecture begins well before the module arrives on site. Engineers must audit the existing SINAMICS S120 drive line-up to confirm backplane slot availability, verify that the Control Unit — typically a CU320-2 DP or CU320-2 PN — carries a firmware version compatible with the replacement module, and document all existing DRIVE-CLiQ topology connections. In multi-axis systems, the DRIVE-CLiQ daisy-chain sequence must be preserved; inserting or removing a node without updating the topology in STARTER or TIA Portal Drive Optimizer will generate fault F01375 and prevent the drive from running.

Power supply sizing is a frequent oversight in retrofit projects. The 6SL3351-6GE35-0AA1 draws its logic supply from the 24 V DC rail shared across the drive line-up. Before installation, confirm that the existing SITOP PSU8600 or equivalent 24 V regulated power supply has sufficient residual capacity to support the additional module load. If the cabinet already operates near the rated output of the power supply, a parallel SITOP expansion module may be required before the retrofit can proceed safely.

Terminal wiring adaptation is equally important. Legacy interface modules may use a different terminal block pitch or connector type than the 6SL3351-6GE35-0AA1. Prepare a wiring cross-reference table mapping each existing signal — enable inputs, fault outputs, speed reference, and encoder feedback — to the corresponding terminal on the replacement module. Where the original installation used a Sensor Module Cabinet-Mounted SMC30 for encoder signal conditioning, verify that the DRIVE-CLiQ cable length from the SMC30 to the new control interface remains within the 100-metre specification.

For systems that include a SIMATIC S7-300 or S7-400 PLC communicating over PROFIBUS DP, the GSD file for the drive must be re-imported into STEP 7 or TIA Portal after the module swap to ensure that the DP slave configuration matches the new hardware. If the migration path leads toward a SIMATIC S7-1500 controller with PROFINET IO, this retrofit is an ideal opportunity to simultaneously upgrade the communication layer, replacing the PROFIBUS CP module with a PROFINET-capable interface and reconfiguring the drive’s telegram type — typically Standard Telegram 1 or 20 — in the process. An Active Line Module and its associated Line Module Booksize Compact may also require parameter re-synchronization if the DC bus configuration changes during the retrofit.

HMI screens connected via a SIMATIC HMI TP700 Comfort or similar panel should be reviewed for any drive-specific tags that reference the old module’s diagnostic addresses. Update the WinCC Flexible or TIA Portal HMI project to reflect the new module’s fault buffer address range and status word mapping before restarting the visualization system. Signal isolators installed between the drive’s analog outputs and the process control system should also be re-ranged if the new module’s output scaling differs from the legacy unit.

Downtime Control During System Migration

Minimizing unplanned downtime is the primary concern for any maintenance team executing a control interface module replacement on a live production line. The recommended approach is to complete all preparatory work — firmware verification, wiring documentation, parameter backup, and spare parts staging — during scheduled maintenance windows before the physical swap takes place. Use STARTER or TIA Portal to perform a full parameter upload from the existing drive system and save the project file to a secure location. This backup preserves all speed controller gains, ramp times, motor data sets, and safety function configurations, allowing rapid restoration if the commissioning of the replacement module encounters unexpected issues.

During the physical replacement, follow a structured lockout/tagout procedure and discharge the DC bus fully before handling any module. Re-install the 6SL3351-6GE35-0AA1, reconnect all DRIVE-CLiQ and terminal wiring according to the cross-reference table prepared during planning, and restore power in stages — 24 V DC logic supply first, then AC mains to the Active Line Module. Download the saved parameter set to the new module, perform a motor identification run if the motor data set was not fully preserved, and validate all safety inputs and outputs before releasing the drive to production. A structured commissioning checklist reduces the risk of overlooked steps and supports the outgoing quality test required before the unit is returned to service.

For critical processes where even a brief interruption is unacceptable, consider staging a pre-configured and pre-tested 6SL3351-6GE35-0AA1 with the target parameter set already loaded. This hot-swap preparation strategy reduces the physical replacement window to the time required for mechanical installation and wiring reconnection, typically under two hours for a single-axis booksize drive.

Retrofit Support FAQ

Q: Is the 6SL3351-6GE35-0AA1 a direct drop-in replacement for older SINAMICS S120 control interface modules?
A: In most cases, yes — provided the backplane slot format, DRIVE-CLiQ port count, and firmware baseline of the Control Unit are compatible. We recommend sharing your existing module part number and firmware version with our technical team before ordering so we can confirm interchangeability and flag any parameter migration steps required.

Q: What commissioning steps are required after installation?
A: After mechanical installation and wiring reconnection, download your backed-up parameter set via STARTER or TIA Portal, verify the DRIVE-CLiQ topology, confirm module address assignments, and perform a function test covering all enable signals, fault acknowledgements, and speed reference channels. If safety functions are active, a safety acceptance test must be completed and documented before the drive is returned to automatic operation.

Q: How do I verify wiring compatibility between the legacy module and the 6SL3351-6GE35-0AA1?
A: Compare the terminal assignment diagrams from both the original module’s hardware installation manual and the 6SL3351-6GE35-0AA1 documentation. Pay particular attention to the 24 V supply terminals, digital input/output assignments, and any analog reference signals. Our team can provide a wiring adaptation guide upon request.

Q: What does the 12-month warranty cover, and is pre-shipment testing performed?
A: Every 6SL3351-6GE35-0AA1 unit supplied by NINERMAS undergoes functional verification testing prior to dispatch. The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions. Units are shipped with test records available upon request. In-stock units are typically dispatched within 1–3 business days of order confirmation.

Product Series

SINAMICS

Country of Origin

DE

Catalog Continuation

More Siemens modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within PLC & Industrial Automation Modules.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack