Original Industrial Spare Part

HIMA H4137 | Safety Switching Relay 99 2413702 — SIL 3 Certified

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: H4137 SIS Safety & Redundancy Systems HIMA

RFQ Ready

Request pricing & availability

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

HIMA H4137 (99 2413702) — Lifecycle Excellence & Technical Performance

Operational Integrity & System Analysis

From the perspective of an Industrial Compliance Consultant, the HIMA H4137 (99 2413702) represents a cornerstone component in maintaining the operational integrity of Safety Instrumented Systems (SIS). Its role extends beyond simple circuit switching — it serves as a certified enforcement node within safety loops, ensuring that process deviations trigger deterministic, fail-safe responses in full alignment with IEC 61508 and IEC 61511 Compliance Standards. The HIMA H4137 (99 2413702) is not merely a relay; it is a lifecycle-managed asset whose Safety Integrity and Original Documentation traceability make it indispensable in regulated industrial environments.

Within the framework of Industry 4.0 architecture, this module demonstrates long-term compatibility with both legacy H-Series platforms and modern HIMax/HIMatrix controllers. Its deterministic switching behavior and diagnostic transparency support Asset Optimization strategies, enabling maintenance teams to extend proof-test intervals and reduce lifecycle costs without compromising System Performance. The module’s hardwired logic architecture ensures immunity to software-induced failures — a critical advantage in cyber-physical production systems.

As a certified original component manufactured under HIMA’s ISO 9001-certified quality management system, the H4137 delivers verifiable safety value. Each unit ships with full factory documentation, contact resistance records, and insulation test certificates — providing the audit trail required by global functional safety frameworks including OSHA PSM, EU Machinery Directive, and IEC 62061.

Compliance & Safety Benchmarks

  • SIL 3 Certified per IEC 61508 — validated for the highest safety integrity level in single-channel architectures
  • T V & CE Marked — independently verified conformance to European safety and electromagnetic compatibility directives
  • Forcibly-Guided Safety Contacts — mechanically linked contact sets prevent dangerous simultaneous closure, eliminating single-point failure modes
  • IP20 Enclosure Rating — suitable for protected panel environments with standard DIN rail (35mm) installation
  • Operating Temperature: -20°C to +60°C — engineered for thermal resilience across diverse industrial climates
  • Response Time 20ms — deterministic actuation speed meets the most demanding safety loop timing requirements
  • Standard Adherence: IEC 61508, IEC 61511, EN 50205, ISO 13849 — comprehensive multi-standard compliance portfolio

Vertical Industry Integration & Optimization

The HIMA H4137 (99 2413702) is engineered to address the unique process safety demands of precision-critical industries:

  • Oil & Gas / Petrochemical: Deployed in Emergency Shutdown (ESD) and High Integrity Pressure Protection Systems (HIPPS), the H4137 provides the fail-safe isolation required to prevent catastrophic overpressure events. Its SIL 3 rating satisfies the most stringent functional safety assessments mandated by API 670 and IEC 61511.
  • Pharmaceutical & Biotech: In GMP-regulated manufacturing, the module supports validated safety interlocks for bioreactor containment, clean-in-place (CIP) systems, and sterilization sequences — where process deviations carry both safety and regulatory consequences.
  • Semiconductor Fabrication: Ultra-clean process environments demand components with zero-contamination profiles and predictable switching behavior. The H4137’s sealed contact architecture and low particulate generation make it suitable for fab-grade safety circuits.
  • Chemical Processing: Hazardous area safety loops — including toxic gas detection responses and exothermic reaction interlocks — rely on the H4137’s rapid, repeatable actuation to enforce process boundaries and protect personnel.
  • Power Generation: Turbine protection systems and generator excitation safety circuits benefit from the module’s 1oo2 and 2oo3 voting architecture compatibility, enabling high-availability safety functions without sacrificing SIL integrity.

Comprehensive Engineering Specifications

Technical Attribute Standard Value
Complete Model Number HIMA H4137 (Part No. 99 2413702)
Component Classification Safety-Related Switching Relay Module
Safety Integrity Level SIL 3 per IEC 61508
Nominal Supply Voltage 24V DC
Contact Configuration Forcibly-guided, mechanically linked safety contacts
Switching Response Time 20ms (typical)
Mechanical Service Life >10,000,000 operations
Electrical Service Life >100,000 cycles at rated load
Operating Temperature Range -20°C to +60°C
Enclosure Protection Rating IP20
Mounting Standard DIN rail, 35mm (EN 60715)
Certifications T V, CE, IEC 61508, EN 50205
Country of Origin Germany
Quality Management System ISO 9001 certified manufacturing

Fulfillment Strategy & Technical Support

  • Factory Sealed Condition: Every HIMA H4137 (99 2413702) unit is dispatched in its original, factory-sealed packaging with intact tamper-evident seals — guaranteeing authenticity and preserving component integrity from warehouse to installation site.
  • Rapid Global Logistics: Leveraging established international freight partnerships, we provide expedited shipping to major industrial hubs across Asia-Pacific, Europe, the Middle East, and the Americas. Real-time shipment tracking and customs documentation support are standard.
  • 12-Month Quality Guarantee for Legacy Systems: All units are covered by a comprehensive 12-month quality assurance guarantee, encompassing material defects, functional failures, and workmanship issues — with priority replacement protocols for critical system downtime scenarios.
  • Original Documentation Package: Shipments include factory test reports, compliance certificates, and installation guidelines — essential for functional safety audits and regulatory submissions.
  • Pre-Sales Technical Consultation: Our engineering team provides application compatibility assessments, SIL verification support, and integration guidance prior to purchase commitment.

Expert Technical FAQ

Q1: What installation compliance requirements apply to the HIMA H4137 (99 2413702) in a SIL 3 safety loop?
A: Installation must conform to IEC 61511-1 Clause 11 requirements, including segregation of safety and non-safety wiring, use of approved cable types, and documented proof-test procedures. The module’s terminal wiring must follow HIMA’s certified application diagrams. All installation activities should be performed by personnel holding functional safety competency qualifications (e.g., T V FS Engineer).

Q2: How does the H4137 perform under extreme environmental conditions such as high humidity or vibration?
A: The H4137 is designed for industrial panel environments (IP20) and has been validated across its full operating temperature range of -20°C to +60°C. For applications involving elevated humidity or mechanical vibration, additional enclosure protection (IP54 or higher cabinet) and vibration-damping DIN rail mounts are recommended to preserve long-term System Performance and contact reliability.

Q3: Is the HIMA H4137 (99 2413702) compatible with third-party safety PLCs and DCS platforms?
A: Yes. The H4137 interfaces via standard discrete I/O connections (24V DC), making it compatible with safety controllers from Siemens, Rockwell Automation, Emerson, Yokogawa, and other major vendors. No proprietary communication protocol is required, ensuring broad System Integrity across multi-vendor architectures.

Q4: What firmware or software version considerations apply to this relay module?
A: As a hardwired safety relay, the HIMA H4137 (99 2413702) contains no embedded firmware or programmable logic. It is therefore immune to software version conflicts, cybersecurity vulnerabilities, and configuration drift — a significant advantage for long-term Lifecycle Management in legacy system environments where software update cycles are constrained.

Q5: How should proof testing be conducted to maintain SIL 3 certification validity?
A: Proof testing intervals and procedures must be defined in the Safety Requirements Specification (SRS) per IEC 61511. Typical proof test activities for the H4137 include contact continuity verification, coil energization testing, forced-guided contact integrity checks, and insulation resistance measurement. All test results must be documented and retained as part of the safety lifecycle record.

Q6: Can the H4137 be reused after a safety system activation event?
A: Post-activation reuse is permissible provided the unit passes a full proof test as described above and shows no evidence of contact damage, coil degradation, or mechanical deformation. HIMA recommends consulting the Original Documentation and engaging a qualified functional safety engineer to assess fitness-for-service before returning the module to active safety duty.


© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667

Product Series

HIMax / HIQUAD

Country of Origin

DE

Reviews

There are no reviews yet.

Be the first to review “HIMA H4137 | Safety Switching Relay 99 2413702 — SIL 3 Certified”

Your email address will not be published. Required fields are marked

Catalog Continuation

More HIMA modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within SIS Safety & Redundancy Systems.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.

CallPhone MailEmail WAChat TopBack