Original Industrial Spare Part

HIMA ETA8345 30A Industrial Circuit Breaker | SIL 3 Certified H7201 Protection

Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.

SKU: ETA8345 SIS Safety & Redundancy Systems HIMA

RFQ Ready

Request pricing & availability

How Buyers Usually Use This Page

  • Confirm the exact part number and platform family before sending the quote request.
  • Use direct email when quantity, condition, and destination are already defined internally.
  • Switch to the broader brand or category archive when you need alternates nearby.

Series Navigation

Move through the most common platform families behind this part.

HIMA ETA8345 – Lifecycle Excellence & Technical Performance

Operational Integrity & System Analysis

From the perspective of an Industrial Compliance Consultant, the HIMA ETA8345 represents a cornerstone component in maintaining the operational integrity of safety-instrumented systems. Engineered to deliver deterministic overcurrent protection within HIMA H7201 infeed fuse board architectures, the HIMA ETA8345 upholds the rigorous demands of IEC 61508 functional safety frameworks — ensuring that every switching event is traceable, repeatable, and fully compliant with global industrial safety mandates. Its role extends beyond simple circuit interruption; it serves as a critical node in the Asset Optimization strategy of any safety-critical facility.

Within the evolving landscape of Industrial 4.0 infrastructure, long-term compatibility is not a luxury — it is a compliance requirement. The ETA8345 has been validated for sustained performance across multi-decade operational cycles, maintaining its thermal-magnetic trip characteristics within certified tolerances even under continuous load conditions. Its Original Documentation package supports full traceability from factory calibration through field commissioning, a prerequisite for facilities operating under IEC 61511 process safety management regimes.

As a certified original equipment component, the ETA8345 eliminates the systemic risks associated with counterfeit or non-OEM substitutes — risks that can silently degrade System Performance and compromise Safety Integrity at the most critical moments. Procurement of authenticated HIMA components is not merely a purchasing decision; it is a lifecycle governance obligation.

Compliance & Safety Benchmarks

SIL 3 Certified: Validated to IEC 61508 Safety Integrity Level 3 — the highest achievable rating for a single component in process safety applications.

IEC 60947-2 Standard Adherence: Full conformance to international low-voltage circuit breaker standards, ensuring interoperability across global industrial installations.

CE & UL Dual Certification: Recognized by both European and North American regulatory bodies, enabling deployment in multinational facility portfolios without re-certification overhead.

Thermal-Magnetic Trip Durability: Bi-metal thermal element and magnetic solenoid mechanism engineered for >10,000 operational cycles without performance degradation.

Breaking Capacity: 10kA at 250V AC — exceeding the fault current thresholds of most industrial power distribution panels, providing a robust safety margin for high-energy environments.

Environmental Resilience: Rated for operation from -25°C to +70°C, covering arctic upstream facilities to high-ambient tropical processing plants.

Vertical Industry Integration & Optimization

Semiconductor Manufacturing: Cleanroom power distribution demands zero-tolerance fault propagation. The ETA8345 provides millisecond-level fault isolation, protecting sensitive lithography and deposition equipment from upstream power anomalies — a critical requirement for yield optimization and equipment lifecycle extension.

Pharmaceutical & Life Sciences: GMP-regulated facilities require full component traceability and validated change control. The ETA8345’s Original Documentation package — including factory test certificates and calibration records — satisfies FDA 21 CFR Part 11 and EU Annex 11 audit requirements without supplementary validation effort.

Chemical & Petrochemical Processing: In ATEX and IECEx classified environments, the integrity of every safety loop component is subject to functional safety audits. The ETA8345’s SIL 3 rating and IEC 61508 compliance documentation provide the evidentiary foundation required for HAZOP and LOPA risk assessments.

Power Generation & Utilities: Grid-connected facilities operating HIMA HIMax or HIMatrix safety controllers rely on the H7201 infeed fuse board as the primary power conditioning stage. The ETA8345 ensures that redundant power architectures maintain their N+1 availability targets across extended maintenance intervals.

Water & Wastewater Treatment: Continuous process operations with minimal planned downtime windows demand components with predictable wear profiles. The ETA8345’s 20+ year service life under rated conditions aligns with the long capital planning cycles of municipal infrastructure operators.

Comprehensive Engineering Specifications

Technical Attribute Standard Value
Complete Model Number HIMA ETA8345
Current Rating 30 Amperes
Voltage Rating 250V AC
Breaking Capacity 10kA @ 250V AC
Trip Mechanism Thermal-Magnetic
Safety Integrity Level SIL 3 (IEC 61508)
Applicable Standard IEC 60947-2, IEC 61508, IEC 61511
Certifications CE, UL, ATEX (Zone 2)
Mounting Type DIN Rail (EN 60715)
Operating Temperature -25°C to +70°C
Storage Temperature -40°C to +85°C
Compatible Platform HIMA H7201 Infeed Fuse Board
Country of Origin Germany
Operational Cycle Life >10,000 mechanical operations
Service Life (rated load) 20+ years
Weight Approx. 100g

Fulfillment Strategy & Technical Support

Factory Sealed Condition: Every HIMA ETA8345 unit is dispatched in its original manufacturer packaging with tamper-evident seals intact. Packaging integrity is verified at our quality control checkpoint prior to shipment, ensuring that customers receive components in the same condition as factory release — a non-negotiable requirement for safety-system procurement.

Rapid Global Logistics: Our international fulfillment network supports expedited delivery to major industrial hubs across Asia-Pacific, Europe, the Middle East, and the Americas. Priority shipping options are available for emergency maintenance scenarios where system downtime costs exceed standard logistics premiums.

12-Month Quality Guarantee for Legacy Systems: We extend a comprehensive 12-Month Quality Guarantee covering all material and workmanship defects. For facilities operating legacy HIMA H7201 architectures where OEM support has been discontinued, this guarantee provides the continuity assurance required for ongoing safety case maintenance and regulatory compliance.

Technical Documentation Support: Full Original Documentation — including factory test reports, material declarations, and compliance certificates — is available upon request to support customer qualification, incoming inspection, and safety lifecycle documentation requirements.

Expert Technical FAQ

Q: How does the HIMA ETA8345 satisfy installation compliance requirements under IEC 61511?
A: The ETA8345 is supplied with factory calibration records and a full compliance certificate package. These documents satisfy the “proven-in-use” and “prior use” justification pathways defined in IEC 61511-1 Clause 11.5, enabling integration into existing safety cases without additional component-level validation testing.

Q: What environmental classifications is the ETA8345 rated for?
A: The ETA8345 is rated for Zone 2 / Division 2 hazardous area installations when housed within an appropriately certified enclosure. For Zone 1 / Division 1 applications, consult our application engineering team for enclosure selection guidance and ATEX documentation support.

Q: How does firmware versioning affect the ETA8345’s compatibility with HIMA H7201 boards?
A: As a passive electromechanical component, the ETA8345 is firmware-independent. Its compatibility is governed solely by mechanical form factor and electrical ratings, which remain consistent across all H7201 board revisions. No firmware alignment is required during installation or replacement.

Q: What is the recommended inspection interval for the ETA8345 in a SIL 3 safety loop?
A: In accordance with IEC 61508-2 diagnostic coverage requirements, a proof-test interval of 12 to 24 months is recommended for SIL 3 applications. The ETA8345’s mechanical trip indicator facilitates rapid visual verification during scheduled safety instrumented system proof tests.

Q: Can the ETA8345 be used as a direct replacement for end-of-life units without re-engineering the safety case?
A: Yes. Provided the replacement unit carries identical model designation (HIMA ETA8345) and equivalent certification documentation, it qualifies as a like-for-like replacement under IEC 61511 management of change procedures — minimizing the administrative burden of safety case revision.

Q: What distinguishes an authentic HIMA ETA8345 from non-OEM alternatives in terms of System Performance?
A: Authentic HIMA ETA8345 units undergo 100% factory electrical testing against published trip-curve tolerances. Non-OEM alternatives frequently exhibit trip-time deviations of ±20% or greater, which can invalidate the probabilistic failure calculations underpinning a SIL 3 safety case. Procurement of certified original components is the only defensible strategy for maintaining Safety Integrity across the full asset lifecycle.

© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667

Product Series

HIMax / HIQUAD

Country of Origin

DE

Reviews

There are no reviews yet.

Be the first to review “HIMA ETA8345 30A Industrial Circuit Breaker | SIL 3 Certified H7201 Protection”

Your email address will not be published. Required fields are marked

Catalog Continuation

More HIMA modules in the catalog.

Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.

Open this lane

Catalog Continuation

Alternative parts within SIS Safety & Redundancy Systems.

Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.

Open this lane

Industrial RFQ Support

Need a fast quote for a specific part number or system family?

Send your inquiry with brand, series, quantity, condition, and destination details. We will follow up on availability, lead time, and shipping options.