Original Industrial Spare Part
GE IS200VCMIH2CAA Safety-Reliable VME Interface Card
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUIS200VCMIH2CAA/IS215VCMIH2CA
- CategorySIS Safety & Redundancy Systems
- BrandGE
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: GE IS200VCMIH2CAA Safety-Reliable VME Interface Card with SKU IS200VCMIH2CAA/IS215VCMIH2CA.
GE IS200VCMIH2CAA Safety-Reliable VME Interface Card for Critical Control Sites
The GE IS200VCMIH2CAA (interchangeable with IS215VCMIH2CA) is a VME-bus interface card engineered for the GE Mark VIe turbine and process control platform. Designed to operate reliably in the most demanding industrial environments, this module serves as a critical communication bridge within the Mark VIe I/O and control architecture, ensuring uninterrupted signal integrity between the controller backbone and field devices. Whether deployed in continuous production facilities, critical interlock loops, or high-electromagnetic-interference control cabinets, the IS200VCMIH2CAA delivers the safety-grade performance that modern industrial operations demand.
At NINERMAS, every IS200VCMIH2CAA unit is sourced from verified supply channels, subjected to pre-shipment functional testing, and backed by a 12-month warranty. Our inventory is maintained to support both planned maintenance schedules and emergency spare-part replacements, minimizing unplanned downtime risk at your critical control site.
Safety Reliability Table
| Parameter | Specification / Capability |
|---|---|
| Part Numbers | IS200VCMIH2CAA / IS215VCMIH2CA |
| Compatible Platform | GE Mark VIe Turbine & Process Control System |
| Module Type | VME-Bus Interface / Communication Card |
| Manufacturer | GE (General Electric) — USA Origin |
| Operating Temperature | 0°C to +60°C (industrial grade) |
| Storage Temperature | -40°C to +85°C |
| Humidity Tolerance | 5% to 95% RH, non-condensing |
| EMI/EMC Protection | Designed for high-EMI industrial cabinet environments |
| Vibration Resistance | Suitable for heavy industrial and rotating machinery sites |
| Dust & Ingress | Panel-mount installation; compatible with sealed control cabinet deployment |
| Communication Interface | VME-bus backplane; Mark VIe I/O network compatible |
| Safety Relevance | Critical interlock and control loop support |
| Pre-Shipment Testing | Full functional verification before dispatch |
| Warranty | 12 Months — covers functional defects under normal operating conditions |
| Lead Time | In stock — same-week dispatch available |
Control Cabinet Risk Reduction Strategy
In a Mark VIe control cabinet, the IS200VCMIH2CAA does not operate in isolation — it is part of a tightly integrated safety and control architecture. Its role as the VME interface card means that any signal drift, communication anomaly, or power fluctuation upstream or downstream can cascade into a control interruption. To mitigate these risks comprehensively, site engineers typically deploy the IS200VCMIH2CAA alongside a suite of complementary modules.
The IS200VCRCH1B VME carrier card provides the physical backplane foundation that the IS200VCMIH2CAA seats into, and its mechanical and electrical integrity directly affects interface card stability. For I/O signal conditioning and field termination, the IS200VCATH1A analog I/O terminal board ensures that sensor signals arriving from thermocouples, RTDs, and 4–20 mA transmitters are accurately conditioned before reaching the controller — reducing the risk of signal drift that could trigger spurious trips or missed alarms.
Power supply reliability is equally critical. The IS200EPCTG1A power converter module and associated IS200EPSMG1A power supply module provide the stable, regulated DC power that the Mark VIe rack demands. Voltage fluctuations or surge events — common in heavy industrial environments near large motor drives, arc furnaces, or welding equipment — can corrupt VME bus communications if power conditioning is inadequate. Surge protection devices installed at the cabinet power entry point further reduce this risk.
For communication architecture integrity, the IS200VCMIH2CAA works in concert with the IS200VSVOH1B servo control card and the IS200TREGH1B turbine regulation card in gas turbine and steam turbine applications. These modules share the VME backplane and rely on the interface card to maintain coherent data exchange with the Mark VIe controller. Any communication anomaly — whether caused by EMI, a failing backplane connector, or a degraded card — can result in erroneous control outputs, making the IS200VCMIH2CAA a high-priority spare in any turbine control room.
In process control and compressor applications, the IS200DSPXH1D digital signal processor card and IS200VCMIH2CAA together manage the high-speed control loops that govern anti-surge protection and load-sharing logic. Maintaining a verified spare of the IS200VCMIH2CAA on-site ensures that a card failure does not force an extended unplanned shutdown while waiting for international procurement. NINERMAS maintains ready stock of these associated Mark VIe components to support complete cabinet-level spare strategies.
Critical Industrial Safety Applications
Petrochemical & Refinery Plants: In continuous hydrocarbon processing, the Mark VIe platform — with the IS200VCMIH2CAA at its communication core — governs compressor anti-surge control, fired heater burner management, and emergency shutdown interlock logic. A communication failure in this environment can trigger a full unit trip, resulting in significant production loss and potential safety incidents. The IS200VCMIH2CAA’s robust VME interface design ensures that control data flows without interruption even in the presence of high-frequency electrical noise generated by variable frequency drives and large rotating equipment.
Power Generation — Gas & Steam Turbines: GE Mark VIe is the standard control platform for GE Frame 6, Frame 7, and Frame 9 gas turbines worldwide. The IS200VCMIH2CAA serves as the VME interface backbone in these turbine control panels, supporting speed control, temperature regulation, fuel valve positioning, and flame detection interlock circuits. Power plant operators in coal, gas, and combined-cycle facilities rely on verified spare cards like the IS200VCMIH2CAA to maintain N+1 redundancy in their control room spare parts inventory.
Mining & Mineral Processing: In open-pit and underground mining operations, control systems managing conveyor drives, crusher controls, and hoisting equipment are exposed to extreme vibration, dust ingress, and wide temperature swings. The IS200VCMIH2CAA, when installed in a properly sealed and climate-controlled control cabinet, provides the communication reliability needed to sustain safe equipment operation and prevent uncontrolled stops that could endanger personnel or damage equipment.
Water & Wastewater Treatment: Municipal and industrial water treatment facilities operating pump stations, aeration systems, and chemical dosing controls depend on continuous PLC and DCS communication. The IS200VCMIH2CAA supports reliable data exchange in these environments, where humidity and chemical vapors can accelerate electronic component degradation. Pre-tested replacement cards from NINERMAS allow maintenance teams to execute rapid card swaps during scheduled outages rather than facing extended emergency procurement delays.
Metallurgy & Steel Production: Electric arc furnaces, rolling mills, and continuous casting lines generate some of the most severe electromagnetic interference found in any industrial environment. The Mark VIe system’s inherent EMI tolerance, supported by the IS200VCMIH2CAA’s VME interface design, makes it a preferred control platform for steel producers who require uninterrupted process control despite extreme electrical noise conditions.
Port & Marine Applications: Ship propulsion control systems, crane drive controllers, and offshore platform safety systems increasingly rely on industrial-grade VME-based control architectures. The IS200VCMIH2CAA’s compatibility with the Mark VIe platform makes it relevant for marine and port automation projects where long-term spare parts availability and 12-month warranty coverage are essential procurement criteria.
Safety and Quality FAQ
Q1: What does the 12-month warranty cover for the IS200VCMIH2CAA?
The 12-month warranty covers all functional defects arising under normal operating conditions consistent with GE Mark VIe system specifications. If the card fails to perform its VME interface function within the warranty period due to a manufacturing or component defect, NINERMAS will provide a replacement unit. The warranty period begins from the date of confirmed delivery. Physical damage caused by incorrect installation, overvoltage events beyond rated limits, or unauthorized modification is excluded.
Q2: What pre-shipment testing is performed on each IS200VCMIH2CAA unit?
Every IS200VCMIH2CAA dispatched by NINERMAS undergoes a functional verification process prior to shipment. This includes power-on testing, VME bus communication verification, and visual inspection for component integrity and connector condition. Units that do not pass functional testing are not dispatched. Test records are retained and can be referenced in the event of a warranty claim.
Q3: Is the IS200VCMIH2CAA fully interchangeable with the IS215VCMIH2CA?
Yes. The IS200VCMIH2CAA and IS215VCMIH2CA are functionally equivalent and cross-compatible within the GE Mark VIe control system architecture. Both part numbers can be used as direct replacements for each other without requiring firmware changes or system reconfiguration in standard Mark VIe applications. If your site has specific firmware revision requirements, please contact our technical team before ordering to confirm compatibility with your installed Mark VIe software version.
Q4: Can NINERMAS support long-term and repeat supply of the IS200VCMIH2CAA for ongoing maintenance programs?
Yes. NINERMAS maintains standing inventory of the IS200VCMIH2CAA and associated Mark VIe spare components to support both one-time emergency replacements and structured annual maintenance procurement programs. We work with power generation, petrochemical, and process industry clients on scheduled spare parts supply agreements to ensure that critical control system components are available when needed, without dependence on unpredictable spot-market availability.
| Product Series | Mark VI |
|---|---|
| Country of Origin | US |
Catalog Continuation
Nearby part numbers around IS200VCM.
Use this lane when the buyer is comparing adjacent model numbers, revision-near items, or closely related spare variants within the same brand family.
Catalog Continuation
More GE modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: 350-E-P5-G5-H-E-E-N-W-SN-D-N
GE 350-E-P5-G5-H-E-E-N-W-SN-D-N | Feeder Retrofit & Modernization Relay
Catalog Continuation
Alternative parts within SIS Safety & Redundancy Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: CL6721X1-A4 12P1824X012
Fisher CL6721X1-A4 12P1824X012 Safety-Reliable Discrete I/O for Critical Sites
SKU: 51405039-175 CC-PA0H01
Honeywell 51405039-175 CC-PA0H01 Safety-Reliable Power for Critical Control Sites
SKU: CP50M0 6DD1661-0AD0