Original Industrial Spare Part
FS-SICC-0001/L20 | Honeywell System Interconnection Cable 20m – Original Spare Parts
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUFS-SICC-0001/L20
- CategorySIS Safety & Redundancy Systems
- BrandHoneywell
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: FS-SICC-0001/L20 | Honeywell System Interconnection Cable 20m - Original Spare Parts with SKU FS-SICC-0001/L20.
FS-SICC-0001/L20 — Honeywell System Interconnection Cable (20m) | Industrial-Grade Original Spare Parts
As a procurement manager sourcing critical components for distributed control systems, reliability and authenticity are non-negotiable. The FS-SICC-0001/L20 is a factory-sealed, 100% Brand New and Factory Sealed Honeywell system interconnection cable engineered to deliver dependable signal transmission between Field Terminal Assemblies (FTAs) and I/O modules across Honeywell DCS platforms. This 20-meter shielded cable is a cornerstone spare part in Industrial Automation environments where signal integrity directly impacts process safety and uptime.
Designed specifically for Honeywell Experion PKS, TDC 3000, and Safety Manager architectures, the FS-SICC-0001/L20 addresses the persistent challenge of electromagnetic interference in high-density control cabinets found in Oil & Gas, Power Generation, and Chemical Processing facilities. Its robust shielded twisted-pair construction ensures clean, low-latency data paths even in electrically noisy PLC System and Control Module environments. 100% Original and Brand New — sourced directly from authorized Honeywell supply channels.
Whether you are expanding an existing Experion PKS installation or replacing aging cables in a legacy TDC 3000 system, this cable delivers the precision and reliability your operation demands. Contact our team today for pricing and lead time confirmation.
Typical Application Scenarios
Oil & Gas Refineries: High-EMI environments in upstream and downstream processing demand shielded interconnection cables that maintain signal fidelity across long FTA-to-controller runs. The FS-SICC-0001/L20 eliminates noise-induced faults that can trigger spurious shutdowns in Safety Instrumented Systems (SIS).
Power Plants: Turbine control and boiler management systems built on Honeywell DCS platforms rely on stable I/O communication. This cable supports continuous operation in high-temperature switchgear rooms where PVC flame-retardant jacketing is a code requirement.
Chemical & Petrochemical Plants: Process automation in batch and continuous chemical production requires cables rated for harsh chemical atmospheres. The tinned-copper conductors resist corrosion, extending service life in aggressive environments.
Water & Wastewater Treatment: SCADA and DCS-integrated water treatment facilities use this cable to connect remote FTAs to central control modules, ensuring reliable analog and digital signal transmission over extended distances.
Pharmaceutical Manufacturing: GMP-compliant automation lines demand traceable, original spare parts. As a 100% Original and Brand New component, the FS-SICC-0001/L20 satisfies validation documentation requirements for FDA-regulated facilities.
Core Features & Technical Advantages
- ✅ 100% Brand New & Factory Sealed — Genuine Honeywell Original Spare Parts with full traceability documentation available upon request.
- ✅ Superior EMI Shielding — Aluminum-mylar foil shield with drain wire provides >85 dB shielding effectiveness, critical for noise-sensitive PLC System and Control Module installations.
- ✅ Wide Operating Temperature Range — Rated -40°C to +85°C, suitable for both outdoor junction boxes and high-temperature control rooms.
- 300V AC/DC Voltage Rating — Safely handles mixed-signal environments where power and control wiring share conduit runs.
- ✅ Pre-Terminated Connectors — Factory-fitted connectors compatible with standard Honeywell FTA terminal blocks; no field crimping or adapters required, reducing installation time by up to 40%.
- Multi-Standard Compliance — UL, CSA, and CE certified; meets IEC 61158 fieldbus wiring requirements for Industrial Automation deployments worldwide.
- ✅ EOL Legacy System Support — Fully backward-compatible with Honeywell TDC 3000 and System 57 platforms, enabling cost-effective life extension of end-of-life control infrastructure.
Technical Specifications & Selection Guide
| Specification | Value |
|---|---|
| Model / Part Number | FS-SICC-0001/L20 |
| Manufacturer | Honeywell |
| Cable Length | 20 meters (65.6 ft) |
| Cable Type | Shielded Twisted Pair (STP) |
| Conductor Material | Tinned Copper |
| Shielding | Aluminum-Mylar Foil + Drain Wire |
| Jacket Material | PVC Flame-Retardant |
| Voltage Rating | 300V AC/DC |
| Operating Temperature | -40°C to +85°C |
| Compliance | UL, CSA, CE, IEC 61158 |
| Compatible Platforms | Honeywell Experion PKS, TDC 3000, Safety Manager, System 57 |
| Condition | 100% Original and Brand New |
| Warranty | 1 Year |
Selection Guide: Choose the FS-SICC-0001/L20 when your FTA-to-controller distance requires a 20-meter run. For shorter runs, Honeywell offers the FS-SICC-0001/L05 (5m) and FS-SICC-0001/L10 (10m) variants. Always verify the FTA model number against the Honeywell system wiring diagram before ordering to ensure connector compatibility.
Logistics & Professional Service
✅ 2-Day Express Shipping Available — In-stock units ship within 24 hours of order confirmation. Global logistics coverage includes North America, Europe, Middle East, and Asia-Pacific regions.
✅ 1-Year Warranty — Every FS-SICC-0001/L20 unit is covered by a 12-month warranty against manufacturing defects. Replacement or full refund guaranteed for verified quality issues.
✅ EOL & Legacy System Specialists — We maintain dedicated inventory of discontinued and hard-to-source Honeywell spare parts, including cables, I/O modules, and power supplies for TDC 3000 and System 57 platforms no longer supported by the OEM.
✅ Documentation Support — Certificate of Origin, Material Test Reports, and Honeywell Datasheets available upon request to support your procurement validation and site acceptance testing processes.
✅ Technical Pre-Sales Consultation — Our engineering team provides free compatibility verification against your existing DCS architecture before purchase, minimizing the risk of incorrect part selection.
FAQ — Frequently Asked Questions
Q1: What is the price of the FS-SICC-0001/L20, and are volume discounts available?
A: The listed price reflects single-unit retail. For orders of 5 units or more, we offer tiered volume discounts of 5-15% depending on quantity. OEM and EPC contractors with recurring procurement needs are encouraged to contact sale@ninermas.com to establish a framework pricing agreement. Quotes are typically returned within 4 business hours.
Q2: What is the lead time if the FS-SICC-0001/L20 is not in stock?
A: In-stock units ship within 1-2 business days. For out-of-stock scenarios, standard lead time is 3-6 weeks depending on Honeywell’s current production schedule. Expedited sourcing through our global supplier network can often reduce this to 2-3 weeks. Contact us for a real-time availability check.
Q3: Can you provide a Datasheet or Certificate of Conformance for the FS-SICC-0001/L20?
A: Yes. The official Honeywell product datasheet, Certificate of Conformance, and Certificate of Origin are available upon request after order placement. These documents support FAT/SAT validation and regulatory compliance audits in pharmaceutical, nuclear, and petrochemical applications.
Q4: Is the FS-SICC-0001/L20 compatible with Honeywell Safety Manager (SIS) systems?
A: Yes. This cable is compatible with Honeywell Safety Manager and FSC (Fail-Safe Controller) platforms. When used in SIL-rated Safety Instrumented System (SIS) loops, installation must comply with IEC 61511 wiring segregation requirements. Our technical team can advise on compliant installation practices.
Q5: How do I verify the cable is genuine Honeywell and not a counterfeit?
A: All units sold through Industrial Control Hub are 100% Original and Brand New, sourced from authorized Honeywell distribution channels. Each cable carries Honeywell’s original part marking and packaging. We provide purchase documentation and, where available, Honeywell factory test records to confirm authenticity.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667
| Product Series | Experion PKS (C200/C300) |
|---|---|
| Country of Origin | NL |
Catalog Continuation
More Honeywell modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: 51305980-184 REVB
Honeywell 51305980-184 REVB | TDC 3000 Industrial Cable Assembly
SKU: 51303940-150 REV G
Buy Honeywell 51303940-150 REV G Cabinet Fan Assembly | Alarm-Integrated Cooling
Catalog Continuation
Alternative parts within SIS Safety & Redundancy Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
Reviews