Original Industrial Spare Part
Foxboro 13AMS2 Differential Pressure Transmitter | New & Original
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU13AMS2
- CategoryDCS Distributed Control Systems
- BrandInvensys Foxboro
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: Foxboro 13AMS2 Differential Pressure Transmitter | New & Original with SKU 13AMS2.
Foxboro 13AMS2 Differential Pressure Transmitter | Reliable Automation Component
Field Application & Operational Analysis
From a Site Reliability Engineer’s perspective, maintaining system availability in continuous process environments demands instrumentation that performs without compromise. The Foxboro 13AMS2 differential pressure transmitter is engineered precisely for this role — delivering stable, repeatable 4-20mA analog output across demanding measurement loops in oil & gas, chemical processing, and water treatment facilities. The Foxboro 13AMS2 directly contributes to operational excellence by eliminating signal drift and reducing unplanned shutdowns in mission-critical automation architectures.
Durability under harsh field conditions is a defining characteristic of this instrument. Rated NEMA 4X / IP66, the 13AMS2 withstands moisture ingress, corrosive atmospheres, and wide ambient temperature swings from -40°C to +85°C. During installation, engineers should verify impulse line routing to prevent condensate traps, confirm manifold valve orientation for proper high/low side alignment, and ensure loop power supply is within the 24V DC nominal specification. Proper grounding of the transmitter housing is essential in electrically noisy industrial environments.
As production lines age and OEM support windows close, securing verified spare inventory of process optimization components like the 13AMS2 becomes a strategic imperative. Holding certified stock of this transmitter as a critical spare eliminates lead-time risk and protects against extended downtime when primary units require recalibration or replacement.
Key Operational Features
High-Accuracy P Measurement: ±0.5% of calibrated span — suitable for precision flow and level applications
Loop-Powered 4-20mA Output: Inherent noise immunity over long cable runs; no separate power wiring required
Live-Zero Fault Detection: 4mA baseline enables immediate identification of open-loop or transmitter failure conditions
Seamless Integration: Direct compatibility with legacy DCS, PLC, and SCADA I/O modules without signal conditioning
Redundancy-Ready Design: Supports dual-transmitter redundant measurement configurations for high-availability process loops
Field-Adjustable Zero & Span: On-site calibration without specialized tools, reducing maintenance overhead
Hazardous Area Approvals: FM, CSA, and ATEX certifications available for zone-classified installations
Maintenance & Performance Benchmarks
The 13AMS2 is architected to integrate cleanly into industrial network architectures of varying scale — from standalone analog loops in legacy plants to distributed I/O modules feeding modern process optimization platforms. Its analog-native design ensures zero protocol translation overhead, making it a preferred choice for system integration projects where deterministic signal latency is required.
Recommended maintenance benchmarks for mission-critical deployments:
Quarterly: Zero and span verification against calibrated reference standard
Semi-Annual: Impulse line inspection, manifold valve exercise, and diaphragm visual check
Annual: Full recalibration with traceable reference; replace manifold valve packing if process fluid is corrosive
As-Needed: Firmware/configuration audit when integrating into upgraded automation components or DCS migration projects
Mean Time Between Failures (MTBF) for properly maintained 13AMS2 units in moderate-duty service typically exceeds 10 years, underscoring its reputation as a cornerstone of operational excellence in process instrumentation.
Comprehensive Data Sheet
| Attribute | Technical Data |
|---|---|
| Model Number | Foxboro 13AMS2 |
| Instrument Type | Differential Pressure Transmitter |
| Output Signal | 4-20mA DC, 2-wire loop-powered |
| Measurement Variable | Differential Pressure ( P) |
| Accuracy | ±0.5% of calibrated span (typical) |
| Supply Voltage | 24V DC nominal (12-45V DC range) |
| Process Connection | 1/4″ NPT female (standard) |
| Wetted Materials | 316L Stainless Steel diaphragm & body |
| Ambient Temperature | -40°C to +85°C (-40°F to +185°F) |
| Enclosure Rating | NEMA 4X / IP66 |
| Hazardous Area Approvals | FM, CSA, ATEX (configuration-dependent) |
| Communication Protocol | Analog 4-20mA (no HART on standard model) |
| Mounting | 2-inch pipe or panel mount (bracket included) |
| Weight | Approx. 6 kg |
| Condition | New & Original, Factory Packaging |
| Warranty | 1 Year |
Professional Logistics & Sourcing Excellence
Every Foxboro 13AMS2 unit shipped from our inventory is sourced directly from authorized distribution channels and arrives in original factory packaging with full documentation — including calibration certificates and material traceability records where applicable. For time-sensitive plant turnarounds, same-day dispatch is available for in-stock units when orders are confirmed before the daily logistics cutoff.
We maintain dedicated global supply channels for end-of-life (EOL) and legacy automation components, ensuring procurement teams can source verified units even when OEM production has ceased. Worldwide express logistics partnerships enable delivery to major industrial hubs across North America, Europe, the Middle East, and Asia-Pacific within 3-7 business days. All shipments include commercial invoice, packing list, and country-of-origin documentation to facilitate smooth customs clearance.
Engineering Support & FAQ
Q1: What are the recommended installation steps for the Foxboro 13AMS2 in a differential flow measurement loop?
A: Mount the transmitter below the process taps for liquid service to ensure impulse lines remain liquid-filled. Connect the high-pressure tap to the H port and low-pressure tap to the L port. Verify 24V DC loop power, set zero with equalizing valve open, then close and apply process pressure to calibrate span. Confirm 4mA at zero P and 20mA at full-scale P.
Q2: Is the 13AMS2 compatible with current DCS and PLC I/O modules?
A: Yes. The 4-20mA analog output is universally compatible with standard analog input cards across all major DCS platforms (Honeywell, Emerson, ABB, Yokogawa) and PLC I/O modules. No signal conditioning or protocol conversion is required.
Q3: Does this model support HART communication for remote configuration?
A: The standard Foxboro 13AMS2 provides analog-only output without HART capability. For HART-enabled differential pressure measurement, consider the Foxboro IDP10 or IMT25 intelligent transmitter series.
Q4: What is the warranty coverage and claim process?
A: All units carry a 1-year warranty against manufacturing defects and material failures from the date of shipment. To initiate a warranty claim, contact our technical support team with the unit serial number, purchase order reference, and a description of the observed fault. Replacement or repair is processed within 5-10 business days upon verification.
Q5: Can the 13AMS2 be recalibrated in the field without returning to the factory?
A: Yes. The transmitter features external zero and span adjustment screws accessible without opening the housing. Field recalibration requires only a calibrated pressure source and a milliamp meter. Full factory recalibration with traceable certification is recommended every 12-24 months for critical measurement loops.
Q6: Are spare parts such as diaphragm assemblies and manifold valves available?
A: Yes. We stock compatible diaphragm assemblies, O-ring kits, and 3-valve manifold sets for the 13AMS2. Contact our team with your specific configuration details for parts availability and lead time.
© 2026 NINERMAS COMPANY LIMITED. All rights reserved. Original Source: https://ninermas.com | Contact: sale@ninermas.com | +0086 187 5021 5667
| Product Series | Other Legacy / Discontinued Modules |
|---|---|
| Country of Origin | US |
Catalog Continuation
Likely Foxboro I/A platform matches.
These parts are closer to the same platform family signaled by the current SKU and title, so buyers can validate continuity before sending a final RFQ.
SKU: FBM04 P0400YE
Foxboro FBM04 P0400YE I/O Module — New & Original in Stock
SKU: FBM218 P0922VWYU
Foxboro FBM218 P0922VW | Retrofit & System Modernization Module
Catalog Continuation
More Invensys Foxboro modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: FBM232 P0926GW
Foxboro FBM232 P0926GW FDSI Module | Original Spare Parts
SKU: FBM233 P0926GX
Foxboro FBM233 P0926GX FDSI Module — New & Original in Stock
SKU: 130K-N4-SF-SAR
Foxboro 130K-N4-SF-SAR | Certified Pneumatic Process Controller
Catalog Continuation
Alternative parts within DCS Distributed Control Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: 51303940-150 REV G
Buy Honeywell 51303940-150 REV G Cabinet Fan Assembly | Alarm-Integrated Cooling
Reviews
There are no reviews yet.