Original Industrial Spare Part
ETA 2210-S211-P1F2-H111-4A Safety-Reliable Circuit Breaker
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKU2210-S211-P1F2-H111-4A
- CategorySIS Safety & Redundancy Systems
- BrandETA
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: ETA 2210-S211-P1F2-H111-4A Safety-Reliable Circuit Breaker with SKU 2210-S211-P1F2-H111-4A.
ETA 2210-S211-P1F2-H111-4A Safety-Reliable Circuit Breaker for Critical Control Sites
The ETA 2210-S211-P1F2-H111-4A is a precision-engineered single-pole thermal-magnetic circuit breaker from ETA’s proven 2210 Series, purpose-built for safety-critical industrial control cabinets, continuous process automation, and high-reliability field installations. Rated at 4A with a compact DIN-rail mounting profile, this device delivers consistent overcurrent and short-circuit protection across demanding environments including petrochemical plants, power distribution substations, mining control rooms, water treatment facilities, metallurgical processing lines, and heavy-duty port and marine automation systems.
In industrial environments where unplanned downtime translates directly into production loss, safety incidents, or regulatory non-compliance, the integrity of every protection device in the control cabinet is non-negotiable. The ETA 2210-S211-P1F2-H111-4A is engineered to eliminate the risk of nuisance tripping, thermal drift, and contact degradation that can compromise control loop continuity. Its thermally compensated bimetal trip mechanism ensures stable response characteristics across a wide ambient temperature range, making it equally reliable in a climate-controlled MCC room and a dusty, high-vibration field enclosure.
Safety Reliability Table
| Parameter | Specification |
|---|---|
| Model / SKU | 2210-S211-P1F2-H111-4A |
| Brand / Manufacturer | ETA (Electric/Electronic Technology Applications) |
| Series | 2210 Series |
| Product Type | Thermal-Magnetic Circuit Breaker |
| Rated Current | 4A |
| Poles | Single-Pole (1P) |
| Trip Mechanism | Thermal-Magnetic (Bimetal + Magnetic) |
| Mounting | DIN Rail (35mm) |
| Operating Voltage | Up to 250V AC / 65V DC (typical 2210 Series) |
| Breaking Capacity | 1500A (typical, application-dependent) |
| Ambient Temperature Range | -25°C to +70°C |
| Protection Class | IP20 (terminal area) |
| Vibration Resistance | Suitable for high-vibration industrial environments |
| EMI / Interference Immunity | Designed for high-EMI control cabinet environments |
| Ingress Protection | Dust and moisture resistant housing |
| Compliance / Standards | IEC/EN 60934, UL 1077 (typical ETA 2210 Series) |
| Country of Origin | Germany |
| Warranty | 12 Months from shipment date |
| Pre-Shipment Testing | Yes — functional and insulation tested before dispatch |
| Long-Term Supply Program | Available — committed stock and fixed lead-time options |
Control Cabinet Risk Reduction Strategy
In a well-engineered industrial control cabinet, the ETA 2210-S211-P1F2-H111-4A serves as the first line of overcurrent defense for branch circuits feeding PLCs, I/O modules, field instruments, and communication gateways. When integrated alongside complementary protection and control components, it forms a layered safety architecture that dramatically reduces the probability of cascading failures.
For 24VDC control power distribution — the backbone of most modern PLC and safety relay architectures — the 2210-S211-P1F2-H111-4A is typically paired with a high-quality DIN rail power supply such as the PULS PIANO PI100.241D or a Phoenix Contact QUINT-PS/1AC/24DC/10. These power supplies deliver stable, regulated 24VDC output, and the ETA breaker provides precise branch-level overcurrent protection, ensuring that a fault on one branch does not collapse the entire 24VDC bus and trigger a system-wide shutdown.
In safety interlock circuits and emergency stop (E-stop) loops, the ETA 2210-S211-P1F2-H111-4A is commonly deployed to protect the supply lines feeding Pilz PNOZ safety relays or Siemens 3SK1 safety relay modules. These safety relays monitor dual-channel E-stop buttons, light curtains, and door interlock switches; any interruption to their supply voltage caused by an unprotected overcurrent event could result in a dangerous uncontrolled machine state. The ETA breaker eliminates this risk by providing fast, reliable disconnection before thermal damage can propagate to the safety relay’s input circuitry.
For distributed I/O architectures using Beckhoff EtherCAT I/O terminals (such as the EK1100 coupler with EL1008 digital input and EL2008 digital output terminals) or Siemens ET 200SP I/O modules, branch circuit protection via the ETA 2210-S211-P1F2-H111-4A ensures that a short circuit on one I/O segment does not propagate upstream to the main PLC power rail. This is particularly critical in large-scale process automation panels where dozens of I/O branches share a common 24VDC supply.
In high-electromagnetic-interference (EMI) environments — such as variable frequency drive (VFD) panels, motor control centers (MCCs), or arc furnace control rooms — signal integrity and power quality are constant concerns. The ETA 2210-S211-P1F2-H111-4A’s robust thermal-magnetic mechanism is immune to the high-frequency noise and transient surges generated by ABB ACS880 drives or Schneider Electric Altivar Process ATV630 drives, ensuring that nuisance tripping does not interrupt critical motor control sequences. Surge protection devices (SPDs) such as the Phoenix Contact VAL-MS 230 ST are often installed upstream to handle transient overvoltages, with the ETA breaker providing the sustained overcurrent protection layer downstream.
For communication infrastructure within the control cabinet — including Moxa EDS-308 managed Ethernet switches or Hirschmann RS20 industrial switches used in PROFINET or EtherNet/IP networks — dedicated branch circuit protection via the ETA 2210-S211-P1F2-H111-4A prevents a power fault from taking down the entire plant communication backbone. Network availability is a direct safety requirement in modern SIL-rated control systems, and protecting communication hardware at the branch level is a recognized best practice in IEC 62443 cybersecurity and functional safety frameworks.
Critical Industrial Safety Applications
Petrochemical and Refinery Plants: In continuous process environments such as crude distillation units, hydrocracker control rooms, and compressor station panels, the ETA 2210-S211-P1F2-H111-4A protects the 24VDC branch circuits feeding flame detectors, gas analyzers, and emergency shutdown (ESD) system I/O modules. Its stable trip characteristics under elevated ambient temperatures — common in heat-traced instrument enclosures — ensure that protection performance does not degrade over the lifecycle of the installation.
Electric Power Generation and Substation Automation: In 110VDC or 220VDC battery-backed substation control panels, ETA 2210 Series breakers are used to protect relay protection circuits, RTU communication modules, and SCADA interface cards. The ability to interrupt DC fault currents reliably — a known challenge for AC-only rated devices — makes the ETA 2210-S211-P1F2-H111-4A a preferred choice for substation engineers specifying IEC 61850-compliant protection panels.
Mining and Mineral Processing: Underground mining control systems and surface concentrator plant MCCs operate in environments with extreme dust loading, humidity cycling, and mechanical vibration from blasting and heavy machinery. The ETA 2210-S211-P1F2-H111-4A’s compact, sealed housing and vibration-resistant construction make it suitable for protecting PLC I/O power supplies, conveyor drive control circuits, and ventilation fan interlock panels in these harsh conditions.
Water and Wastewater Treatment: Municipal water treatment SCADA panels and pump station control cabinets require long-term, maintenance-free operation. The ETA 2210-S211-P1F2-H111-4A provides reliable branch protection for flow meter transmitters, chemical dosing pump controllers, and telemetry RTUs, ensuring that a single instrument fault does not cascade into a treatment process interruption with potential public health consequences.
Metallurgical and Steel Processing: In electric arc furnace (EAF) control rooms and rolling mill automation panels, the combination of extreme EMI, high ambient temperatures, and continuous 24/7 operation demands protection devices with proven long-term stability. The ETA 2210-S211-P1F2-H111-4A’s thermally compensated design maintains consistent trip accuracy even after years of operation in these thermally stressed environments.
Port Automation and Marine Systems: Ship-to-shore crane control panels, automated stacking crane (ASC) systems, and vessel automation switchboards require compact, DIN-rail-mounted protection devices that can withstand salt air, vibration, and wide temperature swings. The ETA 2210-S211-P1F2-H111-4A meets these requirements while providing the precise 4A branch protection needed for PLC and HMI power supply circuits in marine-grade control enclosures.
Safety and Quality FAQ
Q1: What warranty coverage is provided for the ETA 2210-S211-P1F2-H111-4A?
All ETA 2210-S211-P1F2-H111-4A units supplied by NINERMAS carry a 12-month warranty from the date of shipment. This covers manufacturing defects, premature trip mechanism failure, and contact degradation under normal operating conditions. Warranty claims are supported with replacement dispatch within agreed lead times and full documentation traceability.
Q2: Is pre-shipment testing performed on each unit?
Yes. Every ETA 2210-S211-P1F2-H111-4A unit undergoes functional verification and insulation resistance testing before dispatch. Test records are available upon request and accompany shipments for quality-critical applications such as nuclear auxiliary systems, SIL-rated safety loops, and offshore platform control panels.
Q3: Is the ETA 2210-S211-P1F2-H111-4A compatible with existing 2210 Series installations?
Yes. The 2210-S211-P1F2-H111-4A is a direct form-fit-function replacement for existing ETA 2210 Series circuit breakers of the same current rating and pole configuration. It is dimensionally compatible with standard 35mm DIN rail installations and can be substituted without modification to existing wiring or panel layouts, minimizing downtime during planned maintenance or emergency replacement.
Q4: Can NINERMAS support long-term supply commitments for this part?
Yes. NINERMAS operates a long-term spare parts supply program for industrial automation components including the ETA 2210 Series. We maintain committed stock levels and offer fixed lead-time agreements to support lifecycle extension programs, planned maintenance shutdowns, and multi-year MRO contracts. Contact our technical sales team to discuss volume pricing, consignment stock arrangements, and supply continuity agreements tailored to your plant’s maintenance schedule.
| Product Series | Other series |
|---|
Catalog Continuation
Alternative parts within SIS Safety & Redundancy Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: KFD2-VM-EX1.35
Pepperl+Fuchs KFD2-VM-EX1.35 Safety-Reliable Signal Conditioner
SKU: DSQC651 3HEA800439-002