Original Industrial Spare Part
ABB BC810K02 3BSE031155R1 Retrofit CEX-Bus Unit Legacy
Verify the part, confirm the platform family, and move straight into quotation with the right commercial details.
RFQ Ready
- SKUBC810K02 3BSE031155R1
- CategoryDCS Distributed Control Systems
- BrandABB
- SupportAvailability, lead time, condition, and shipping coordination
How Buyers Usually Use This Page
- Confirm the exact part number and platform family before sending the quote request.
- Use direct email when quantity, condition, and destination are already defined internally.
- Switch to the broader brand or category archive when you need alternates nearby.
Series Navigation
Move through the most common platform families behind this part.
Product RFQ
Send this part directly for quotation.
Include quantity, required condition, destination country, and target delivery timing. Current reference: ABB BC810K02 3BSE031155R1 Retrofit CEX-Bus Unit Legacy with SKU BC810K02 3BSE031155R1.
ABB BC810K02 3BSE031155R1 Retrofit-Compatible CEX-Bus Unit for Legacy Systems
The ABB BC810K02 (3BSE031155R1) is a CEX-Bus communication unit designed for the ABB AC800M controller platform — one of the most widely deployed distributed control architectures in process automation, power generation, and heavy industry. As ABB progressively phases out legacy hardware within the AC800M ecosystem, the BC810K02 has become a critical retrofit and replacement component for facilities seeking to extend the operational life of their existing control infrastructure without committing to a full DCS migration.
NINERMAS maintains verified stock of the BC810K02 3BSE031155R1, fully tested and backed by a 12-month warranty. Each unit undergoes pre-shipment functional verification to confirm CEX-Bus communication integrity, backplane slot compatibility, and module addressing before dispatch.
Upgrade Compatibility Table
| Parameter | BC810K02 / 3BSE031155R1 | Retrofit Notes |
|---|---|---|
| Platform | ABB AC800M | Compatible with PM861, PM864, PM866 controller modules |
| Bus Interface | CEX-Bus (Controller Extension Bus) | Verify CEX-Bus slot availability on existing backplane |
| Backplane Compatibility | TB820V2, TB840A, TB842 I/O clusters | Confirm rack slot addressing before installation |
| Communication Protocol | Proprietary ABB CEX-Bus | No protocol conversion required within AC800M architecture |
| Power Supply Requirement | 24 VDC via backplane | Verify SD821 or SD822 power supply capacity before swap |
| Module Addressing | Configured via Control Builder M | Re-import hardware configuration after replacement |
| Installation Format | Rack-mounted, DIN-rail compatible chassis | Confirm physical slot clearance in existing cabinet |
| HMI Compatibility | ABB 800xA, Freelance, Symphony Plus | No HMI screen rebuild required for like-for-like swap |
| Replacement Path | Direct drop-in for BC810K02 variants | Confirm firmware revision compatibility with PM8xx controller |
| Warranty | 12-Month Warranty — All units pre-tested before shipment | |
Retrofit Planning for Existing Automation Systems
Replacing the BC810K02 within a live AC800M system requires careful pre-planning to avoid unintended disruption to connected I/O clusters and field devices. The CEX-Bus architecture links the PM8xx controller module to remote I/O stations — typically populated with AI810 analog input modules, AO810V2 analog output modules, DI810 digital input modules, and DO810 digital output modules mounted on TB820V2 or TB840A baseplate assemblies. Before removing the existing BC810K02, engineers should export the full hardware configuration from Control Builder M and document all node addresses, CEX-Bus segment assignments, and I/O channel mappings.
Power supply capacity is a frequent oversight during CEX-Bus unit replacement. The SD821 and SD822 24 VDC power supply modules feeding the backplane must be verified to support the full load of the replacement unit alongside all co-installed I/O modules. If the existing power budget is marginal, a parallel redundant power supply configuration using a second SD821 should be considered before the retrofit window opens.
For systems where the BC810K02 bridges communication between the AC800M controller and a CI854A PROFIBUS DP interface module or a CI857 PROFINET interface module, the communication link parameters — baud rate, station address, and watchdog timeout — must be re-validated after the new unit is seated. In multi-segment CEX-Bus topologies, the segment termination resistors on the TB807 or TB811 bus termination modules must remain correctly configured to prevent reflection errors on the bus.
Cabinet space confirmation is essential, particularly in legacy control rooms where rack density is high. The BC810K02 occupies a standard AC800M module slot; however, adjacent modules such as the PM864A controller or co-installed BC810 redundancy units may restrict airflow if the cabinet layout has been modified over time. A physical site survey of the control cabinet interior is recommended before scheduling the maintenance window.
For facilities running ABB 800xA as the supervisory layer, the Asset Optimization and Batch Management functions linked to the replaced I/O cluster should be placed in manual override mode during the swap to prevent spurious alarms from propagating to the operator workstation. Once the BC810K02 is replaced and the CEX-Bus segment is re-established, a structured loop check across all connected analog and digital channels confirms signal integrity before returning the system to automatic control.
Downtime Control During System Migration
Minimizing downtime during a BC810K02 replacement begins with a structured pre-outage checklist. The existing program logic resident in the PM861A or PM864A controller is stored in non-volatile memory and is not affected by removing the CEX-Bus unit — however, any unsaved online changes made through Control Builder M must be compiled and downloaded to the controller before the maintenance window begins. This protects the application program from version mismatch after the hardware swap.
A cold-swap procedure is standard for BC810K02 replacement: the affected CEX-Bus segment is powered down, the module is extracted, the replacement unit is seated and secured, and the segment is re-energized. Total physical swap time is typically under 15 minutes for a prepared technician. The majority of the maintenance window is consumed by pre-swap configuration export, post-swap hardware re-import into Control Builder M, and structured I/O loop verification.
For critical process lines where even a brief interruption is unacceptable, a parallel hot-standby approach using a redundant BC810K02 pair — where the system supports CEX-Bus redundancy — allows the replacement unit to be synchronized before the primary is taken offline. This approach requires that the existing system was originally commissioned with redundant CEX-Bus hardware; it cannot be retrofitted without corresponding changes to the PM8xx controller configuration and backplane wiring.
Post-replacement, a 30-minute supervised observation period with the process returned to automatic control is recommended. During this window, the operator should monitor CEX-Bus communication status indicators on the 800xA faceplate, verify that all I/O modules report healthy status in the hardware tree, and confirm that no diagnostic alarms are active on the replaced segment. NINERMAS provides post-sale technical support to assist with commissioning queries for all supplied units within the 12-month warranty period.
Retrofit Support FAQ
Q1: Is the BC810K02 3BSE031155R1 a direct drop-in replacement for the original BC810K02?
Yes. The 3BSE031155R1 is the ABB catalog reference for the BC810K02 CEX-Bus unit. It is a direct form-fit-function replacement for the original module within the AC800M platform. No hardware modification or firmware update is required for a like-for-like swap, provided the host controller firmware is at a compatible revision level. NINERMAS recommends confirming the PM8xx controller firmware version before dispatch to ensure full compatibility.
Q2: What pre-shipment testing does NINERMAS perform on the BC810K02?
Each BC810K02 3BSE031155R1 unit supplied by NINERMAS undergoes functional power-on verification, CEX-Bus communication self-test, and visual inspection for connector pin integrity and PCB condition before shipment. Units are packed in anti-static ESD-safe packaging with desiccant to protect against humidity during transit. A 12-month warranty is provided from the date of shipment, covering manufacturing defects and functional failure under normal operating conditions.
Q3: Can the BC810K02 be used in a CEX-Bus redundant configuration?
Yes, the BC810K02 supports CEX-Bus redundancy when paired with a second BC810K02 unit and a compatible PM8xx controller configured for redundant operation. The redundant pair operates in active/standby mode, with automatic bumpless transfer on primary unit failure. Both units must be at the same hardware revision and firmware level for redundancy to function correctly. Contact NINERMAS if you require a matched redundant pair — we can supply and pre-verify both units together.
Q4: What is the lead time and stock availability for the BC810K02 3BSE031155R1?
NINERMAS maintains ready stock of the BC810K02 3BSE031155R1 to support urgent retrofit and breakdown replacement requirements. Standard lead time for in-stock units is 3–5 business days for international shipment. For large-quantity procurement or long-term spare parts program agreements, NINERMAS offers committed stock reservation with scheduled delivery to support planned maintenance cycles. Contact our team at sale@ninermas.com or +0086 187 5021 5667 to confirm current availability and pricing.
| Product Series | AC800M |
|---|---|
| Country of Origin | SE |
Catalog Continuation
More ABB modules in the catalog.
Use the brand lane to compare nearby part numbers, platform-adjacent modules, and other inquiry-ready listings before sending your final RFQ.
SKU: AI625 3BHT300036R1
ABB AI625 3BHT300036R1 Retrofit Analog Input Module
SKU: 3HAC062339-004 3HAC062339-006 lRB7600 3HAC064662-001 DSQC3037 3HAC023195-001
ABB 3HAC062339-004 Service-Ready Spare Part for Industrial Maintenance
SKU: 3BSE003127R1 DSAI130D
ABB 3BSE003127R1 DSAI130D Retrofit-Compatible Analog Input Module
SKU: GJR2389800R1210 81ET03I1-E
ABB GJR2389800R1210 81ET03I1-E Spare Part for AC500 PLC
Catalog Continuation
Alternative parts within DCS Distributed Control Systems.
Stay inside the same system family when you need substitutes, adjacent modules, or a broader shortlist for procurement review.
SKU: CC-TD0R01 51308376-175
Honeywell CC-TD0R01 51308376-175 Spare Part for Maintenance
SKU: CE4006P2 KJ3241X1-BA1 12P2506X102
EMERSON CE4006P2 KJ3241X1-BA1 12P2506X102 DeltaV I/O
SKU: 8C-PCNT02 51454363-275
Honeywell 8C-PCNT02 51454363-275 Spare Part for Maintenance